background image

Installation Instructions

F 1803 Vi, F 1813 Vi                en - CA  
F 1903 Vi, F 1913 Vi


,QVWDOODWLRQUHSDLUDQGPDLQWHQDQFHZRUNVKRXOGEHSHUIRUPHGE\
D0LHOHDXWKRUL]HGVHUYLFHWHFKQLFLDQLQDFFRUGDQFHZLWKQDWLRQDO
DQGORFDOVDIHW\UHJXODWLRQVDQGWKHSURYLGHGLQVWDOODWLRQLQVWUXFWLRQV

Содержание F 1803 Vi

Страница 1: ...i F 1813 Vi en CA F 1903 Vi F 1913 Vi QVWDOODWLRQ UHSDLU DQG PDLQWHQDQFH ZRUN VKRXOG EH SHUIRUPHG E D 0LHOH DXWKRUL HG VHUYLFH WHFKQLFLDQ LQ DFFRUGDQFH ZLWK QDWLRQDO DQG ORFDO VDIHW UHJXODWLRQV DQG WKH SURYLGHG LQVWDOODWLRQ LQVWUXFWLRQV ...

Страница 2: ...er Disposal of your old appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Please take care not to damage the pipework while the appliance is being stored for transport to a waste disposal facility By protecting the pipework you help keep the coolants and compressor oil from contaminat...

Страница 3: ...temperature in the appliance to rise with the risk of food deteriorating and going off Installation site The appliance should be installed in a dry well ventilated room Do not install the appliance outdoors in an environment with dripping water in rooms that are at risk of frost The installation location should not be exposed to direct sunlight nor near a heat source such as an oven radiator etc T...

Страница 4: ...nditioned room with sufficient ventilation Please ensure that doors close and seal properly after installation and that the appliance is installed in accordance with these installation instructions and and with the required ventilation openings If the room is too cold it will cause the cooling system in the appliance to remain off for too long This can cause the temperature in the appliance to ris...

Страница 5: ... it is essential that all attachable furniture fixtures be connected securely to the floor or wall by a suitable means Ventilation The air intake and outlet must not be blocked or covered in any way They also need to be dusted cleaned on a regular basis Installation niche To ensure safe trouble free installation and the best possible cosmetic result check to be sure that the installation space com...

Страница 6: ... appliance can be installed at any preferred location in the kitchen However be sure the door will open and close properly in the chosen location Side by side This appliance can be installed side by side with another fridge freezer using a Merging Kit The Merging Kit is available from Miele Contact Miele or your dealer for specific information about which combinations will work with your appliance...

Страница 7: ...uded The Merging Kit will also be needed Power bars or extension cords are not safe risk of fire Do not use them to connect the appliance to the power supply The Merging Kit is available from Miele Installation with partition without using the Merging Kit If there is a partition with a thickness of more than 6 5 16 160 mm between the adjacent appliances then each appliance should be individually i...

Страница 8: ...uring installation ensure that the cavity is square and the measurements are correct Front panel gap kit optional accessory Two adjacent doors can be attached instead of one large door To connect these doors on the rear a metal strip can be purchased as an optional accessory Contact Miele When attaching the metal strip to the furniture doors observe the maximum length of the screws and the positio...

Страница 9: ...oor handle 14 5 16 363 mm F 19X3 Vi 38 11 16 982 mm Door front max 1 1 2 38 mm Door handle 16 7 8 428 mm The dimensions of the door fronts and handles will vary according to each individual kitchen Miele recommends using the full door opening angle of 115 for this freezer Dimensions 53 ...

Страница 10: ...Niche dimensions Niche width A F 18X3 Vi 30 762 mm F 19X3 Vi 36 915 mm Dimensions 54 ...

Страница 11: ...Door front dimensions A B F 18X3 Vi 79 7 8 2029 mm 29 3 4 756 mm F 19X3 Vi 79 7 8 2029 mm 35 3 4 908 mm 4 5 3 16 102 132 mm Dimensions 55 ...

Страница 12: ...Canadian Electric code C22 1 latest edition Provincial and Municipal codes and or local codes Tools needed for installation Cordless screwdriver Torx screwdriver Hammer drill Wood drills in different sizes Hammer Rachet 5 16 8 mm Adhesive tape Multi grip pliers Level Tape measure Square When fastening the cabinet to the wall behind it see Installing the appliance use suitable plugs screws dependin...

Страница 13: ...ce complies with the installation requirements Check the base see Installation Check the dimensions of the cavity Check that the cavity is square Check the location of the power outlet Check the location of the water connection see Plumbing Check that all furniture parts in the vicinity of the appliance are securely connected to the wall Check that the adjacent furniture fixtures do not collide wi...

Страница 14: ...iance is no longer secured and may be unstable From the rear of the appliance carefully lift it from the pallet Once the appliance is on the ground it can be wheeled around RemoteVision module installation optional accessory Always disconnect the appliance from the power supply when performing installation maintenance or service work Install the RemoteVision module before placing the appliance in ...

Страница 15: ...cessful In that case repeat the process If that does not correct the problem contact Miele Pull the antenna d straight out Guide the cover b over the antenna d and screw on the cover Angle the antenna d so that it faces to the right or left If necessary disconnect the power supply and continue installing the appliance Preparing the installation niche Keep the appliance door closed until it is secu...

Страница 16: ...ecommended for each appliance For side by side installations 4 brackets are recommended Position the anti tip brackets on the left and right in the installation niche so that there is no more than 3 8 10 mm of space between the brackets and the side walls Mark the drill holes in the anti tip brackets on the back wall and on the ceiling of the installation niche Set the brackets aside they will be ...

Страница 17: ...ct a beam with a larger cross section or attach two beams The beam must cover the appliance by at least 2 50 8 mm Mark the installation height lower edge of the beam on the rear wall of the niche Select screws according to the thickness of the wooden beam Example 3 screw for 2x4 beam Determine the number of screws based on the niche width to ensure that the beam will be attached securely Locate wa...

Страница 18: ...be completed via the circuit breaker In the case of side by side installations a separate outlet must be used for each appliance To prevent the power cord from becoming caught Tie a piece of string to the middle of the power cord and feed it forward under the appliance When sliding the appliance in pull the cable forward b Carefully slide the appliance into the space If resistance is felt when att...

Страница 19: ... align the installation aids c on the door Important When unscrewing the height adjustable feet proceed gradually alternating between left and right Unscrew the height adjustable feet until the mark on the base has reached the indicated guide dimension 1 1 4 32 mm The guide dimension of 1 1 4 32 mm is related to a niche height of 84 2134 mm Align the appliance again using a level Note When unscrew...

Страница 20: ...ides of the installation niche Pull out the plate side lugs g Secure the attachment plate side lugs If there is a fairly large gap above the appliance cut a wooden beam to fit exactly and place it in the gap If necessary shorten the filler strip h to the required height Place the 2 strips on top of each other i Insert the filler strip until you hear it click into place j Installing the appliance 6...

Страница 21: ... second filler strip on the peg and press both filler strips together Insert both filler strips into the installation space above the appliance until they click into place Open the appliance door Screw the attachment plate lugs k to the adjacent furniture fixtures With side by side combinations only the external side of the appliances can be secured to the niche Now connect the water supply to the...

Страница 22: ...rips m you will need them again later Remove the light switch cover see arrow Close the appliance door Measure the distance X between the bracket from the door and the overhead furniture fixtures Loosen the two nuts Set aside the nuts you will need them again later With the inside facing up lay the custom door on a stable surface to avoid scratch marks place some plastic or a cloth on the surface ...

Страница 23: ...p with at least 10 screws Please note When attaching the mounting frame onto two adjacent doors see Front panel gap kit screw into the thicker outer frames of the doors only The bracket includes a variety of holes for the various design options of custom doors When performing work on the custom door always observe the following Always select the best load bearing surface of the custom door as the ...

Страница 24: ...es of the appliance door Bag E contains spare screws for this purpose Screw the nuts o a few turns onto the threaded bolts n Do not tighten the nuts completely Close the appliance door and check the distance to doors of adjacent furniture fixtures Align the custom door height with the threaded bolts n Align the appliance door depth with the recesses in the angle trim m Then screw the angle trims i...

Страница 25: ...a hole in the custom door front Screw the fixing bracket securely to the custom door front 3 Tighten the screw 4 Put the cover on the bracket 5 The number of lower brackets will depend on the width and the design of the custom door Attaching the covers To mount the cover strips on both sides of the door click them into place from bottom to top into the gap between the appliance door and the custom...

Страница 26: ...s only Attach the light switch cover Attaching the toe kick cover The maximum height of the toe kick cover is 4 from the top of the floor Do not cover the ventilation slits in the plinth Risk of damage to the appliance If required cut the toe kick cover to the required length and height Attach the plinth to the appliance and put the included cover plates in place Installing the appliance 70 ...

Страница 27: ... Remove the foil from the adhesive strips Attach the toe kick cover to the plinth Installing the appliance 71 ...

Страница 28: ...g into the machine optimizing the energy performance of the unit If necessary shorten the three parts of the air separator Insert the foam pieces back into the sides Position the air separator in the center of the appliance door From below screw the air separator firmly onto the door with the 2 screws Installing the appliance 72 ...

Страница 29: ... for connection to the cold water supply The water pressure must be between 25 and 80 psi 1 7 5 5 bar A separate shut off valve must be installed so that the water supply can be interrupted as needed The maximum outer diameter of the water pipe without fittings 3 8 10 mm The shut off valve for the water connection must not be located behind the appliance It is recommended to place the shut off val...

Страница 30: ...Always observe the indicated clearance dimensions to prevent damage to the connecting pipe when pushing in the appliance Secure the connecting pipe to the floor with adhesive tape You may now proceed to install the appliance See Installing the appliance For appliances with a hose guide position the device in front of the niche and push the stainless steel tube through the hose guide at the back of...

Страница 31: ...o suit the location of the connection on the appliance 2 Push the union nut and seal onto the water pipe Push the end of the water pipe into the appliance connection and screw on the union nut 3 First tighten by hand Then use an open ended wrench to tighten the union nut Do not over tighten Open the shut off valve and the main water connection Check for leaks at the connection for the shut off val...

Страница 32: ...estions regarding the electrical connection of this appliance to the power supply please consult a licensed electrician or call the Miele Technical Service U1 800 999 1360 V1 800 565 6435 The appliance is supplied with a UL listed 3 wire power cord and NEMA 5 15 P plug ready for connection to a 120 V 60 Hz supply The fuse rating is 15 amps The appliance requires a 3 wire receptacle The receptacle ...

Страница 33: ...sult in a short circuit Do not use an extension cord to connect the appliance to the power supply Extension cords do not guarantee the required safety of the appliance e g they pose a danger of overheating Do not connect the appliance to stand alone inverters such as those used with an autonomous energy source e g solar power systems Otherwise when the appliance is switched on peak loads in the sy...

Страница 34: ...stallation section of this manual Be sure your wireless system meets the following requirements A wireless router that supports an IEEE 802 11b g protocol Windows XP or newer operating system Mac OS X 10 3 or higher Cable or DSL modem Microsoft Internet Explorer 6 or higher Safari 2 0 or higher Firefox 1 5 or higher Please note that each wireless router manufacturer supplies their own device drive...

Страница 35: ...ess button p to confirm See the table on the following page for a description of each setting in the display Use the Y or X buttons to select the RemoteVision options The module has been connected to the network when appears in the display If does not appear refer to the Network options section of the XKM 2000 Installation Instruction manual Press and hold the access button p for 2 seconds to conf...

Страница 36: ...ork established no IP address assigned Solid Connected to network Flashing In Ad Hoc Mode not connected Flashing In Ad Hoc Mode connected Selectable options Description of function Back 2 Reboot the module 3 Reset to factory settings 4 Enter Ad Hoc Mode Note If you cannot select any option other than Back the module has not been installed correctly RemoteVision optional accessory 80 ...

Страница 37: ...81 ...

Страница 38: ...82 ...

Страница 39: ...83 ...

Страница 40: ...M Nr 10 102 110 01 en US CA F 1803 Vi F 1813 Vi F 1903 Vi F 1913 Vi ...

Отзывы: