Technical Information
14
DG 408x Steam Ovens
3 Fault
Repair
3.1
Fan Coastdown Too Long
Symptom:
Coastdown is at least 8 minutes and can be more than 60 minutes.
Cause:
Steam generator remains in the appliance after cooking has ended.
Coastdown duration depends on whether or not the steam generator has
been removed from the appliance after the cooking process. Warm cooked
food in the appliance delays the cooling and leads to a longer coastdown.
Coastdown time is not adjustable!
Steam generator was removed:
Coastdown takes at least 8 minutes. If
after the first 8 minutes the interior temperature has not reduced to below
113°F (45°C), then the coastdown is extended for an additional 8 minutes
until the interior temperature drops below 113°F (45°C).
Steam generator was not removed:
Coastdown takes at least 60
minutes. If after 60 minutes the oven cavity temperature has not dropped
below 45°C, the coastdown duration is extended in increments of 8
minutes until the oven cavity temperature is below 45°C. In addition, if
food remains in the oven cavity, the cooling-off period is delayed and
causes a longer coastdown.
Remedy:
1. Remove steam generator and cooked food after a cooking program.
2. Leave door open.
3. Empty steam generator before inserting it again.
3.2
Top Clearance Too Small When Combined with Warming Drawer (DG 4080)
Symptom:
When combining the appliance with the built-in EGW 4000 warming drawer,
the clearance on top to the cabinetry is too small. This becomes particularly
obvious if other Miele machines are built in next to it.
Cause:
Two screw heads at the bottom of the appliance meet exactly with rivets at
the top of the EGW 4000 warming drawer. This causes the appliance to be
positioned slightly higher, and the gap within the cabinetry to be insufficient to
allow proper installation.
Series modification:
The position of the rivets on the warming drawer has been changed so that
the screw caps will not meet the rivets.
Remedy:
Note:
Both screws can be permanently removed, since they are only used during
production and will not have any adverse effects if removed.
Remove both screws (Figure 010-2, Item 1).
Содержание DG 408 Series
Страница 1: ...TECHNICAL INFORMATION DG 408x Steam Ovens 2012 Miele USA ...
Страница 11: ...Technical Information 11 DG 408x Steam Ovens 010 Casing DG 4080 DG 4082 ...
Страница 21: ...Technical Information 21 DG 408x Steam Ovens 020 Door DG 4080 DG 4082 ...
Страница 24: ...Technical Information 24 DG 408x Steam Ovens 030 Oven Cavity DG 4080 DG 4082 ...
Страница 29: ...Technical Information 29 DG 408x Steam Ovens 040 Water Tank ...
Страница 38: ...Technical Information 38 DG 408x Steam Ovens 060 Fascia Electronics DG 4080 DG 4082 ...