background image

Warning and safety instructions

Never leave the unit unattended
when cooking with oil or fat. Very

hot oil can ignite and damage the ex-
tractor.

Try to prevent drops of soup,
sauce, etc., or residues from the

grease filter from finding their way into
the interior of the appliance.
Should this occur however, cleaning
should only be performed by the Miele
Service Department, since the fan cas-
ing will have to be taken completely
apart.

Do not use the extractor without
the grease filter in place.

Clean the grease filter regularly. An
over-greasy filter is a fire hazard.

Do not use a steam-cleaner to
clean the extractor.

The steam could penetrate to electrical
components and cause a short circuit.

For the installer and electrician

Ensure that the electrical connec-
tion in the house and the details on

the data plate correspond.

Do not install the extractor beside
appliances burning solid fuel.

All ducting, pipework and fittings
must be of non-flammable material.

The appliance must not be con-
nected to a chimney or vent flue.

Neither should it be connected to duct-
ing which ventilates rooms with fire-
places.

If exhaust air is to be vented into a
chimney or ventilation duct no

longer serving other purposes, seek
professional advice.

Ensure there is sufficient ventilation
in the room when the extractor is in

operation.
When using the extractor at the same
time as other heating appliances which
depend on the air in the room (e.g.
gas, oil or coal fired heaters, con-
tinuous flow or other water heater, gas
cooktop or gas oven), make certain
that ventillation is adequate as the ex-
tractor will remove air from the room,
which these heaters need for combus-
tion.
In order to ensure safe operation, and
to prevent the exhaust gases of the
heating appliances from being drawn
into the room when the extractor and
heater are in operation simultaneously,
an underpressure of 0.06 psi (4pa) is
the maximum permissible in the room.
Ventilation can be maintained by air in-
lets in windows, doors and outside
walls, or by other means, such as en-
suring that the extractor can only be
turned on when the heating appliance
is off and vice-versa.

Keep these operating instructions in
a safe place for future reference and
pass them on to future owners if ap-
plicable.

Warning and safety instructions

7

Содержание DA 8-2

Страница 1: ...Operating instructions for the DA 8 2 Extractor ö M Nr 03 997 810 ...

Страница 2: ...Description of the appliance 1 2 6 5 4 3 Description of the appliance 2 ...

Страница 3: ...20 mm diameter exhaust connection e Extraction warning label f Control knob g Control panel Data plate Because the data plate is no longer visible once the appliance has been in stalled a 2nd data plate is supplied It should be placed into the space pro vided on page 11 of these instructions Do not install the DA 8 2 directly next to a gas hob Description of the appliance 3 ...

Страница 4: ...m secondary raw materials Rather than throwing these materials away please take them to the nearest recycling center for specific waste Disposal of your old machine Old machines contain materials which can be recycled Please contact your local recycling center or scrap mer chant about potential recycling pro grams before disposing of the ap pliance Read the notes on page 8 before dis posing of the...

Страница 5: ...protect our environment 4 Warning and safety instructions 6 Operation 9 Cleaning and care 10 After Sales Service 11 Electrical connection 12 Appliance dimensions 13 Installation instructions 14 Exhaust connection 16 Exhaust connections 17 Contents ...

Страница 6: ...damage caused by the lack or inadequacy of an effective grounding system Installation and repairs should only be performed by qualified and trained personnel Repairs by unquali fied personnel could be dangerous Do not connect the appliance to the main electrical supply using an extension cord Extension cords do not guarantee the required safety of the ap pliance Before servicing disconnect the pow...

Страница 7: ... it be connected to duct ing which ventilates rooms with fire places If exhaust air is to be vented into a chimney or ventilation duct no longer serving other purposes seek professional advice Ensure there is sufficient ventilation in the room when the extractor is in operation When using the extractor at the same time as other heating appliances which depend on the air in the room e g gas oil or ...

Страница 8: ...ff the ap pliance as close to the housing as possible The plug and cord should be disposed of and not used elsewhere in the house electric shock hazard Text highlighted in boxes is of par ticular importance and should be read in conjunction with the warning and safety instructions Warning and safety instructions 8 ...

Страница 9: ...ing to cook Turn the control knob f clockwise Select a power setting strong enough to clear the air Setting 1 for normal operation Setting 2 for removing heavy cooking odors After cooking Turn the control knob counter clock wise to 0 Operation 9 ...

Страница 10: ...e appliance If this does happen the Service Department will have to be called to clean the appliance as the fan casing will need to be dis mantled Loosen both screws on the grease fil ter and remove the drip tray Clean the grease filter the ventilation grill and the drip tray By hand in a solution of hot water and detergent using a nylon brush or In a dishwasher the grease filter the ventilation g...

Страница 11: ...e contact Your Miele Dealer or The Miele Service Department Space for enclosed data plate The address of the nearest Service De partment is given on the back page When contacting the Service Depart ment please quote the Model and Ser ial No of the appliance After Sales Service 11 ...

Страница 12: ...4 ft cord ready for connection to a 120 VAC 60 Hz power supply Connec tion should be made in an appropriate junction box The rated load is 110 W Fuse rating is 10 A Important The wires of the power cord are color coded as follows Green Yellow ground Blue neutral Brown live As the colors of the wires in the power supply cord of this appliance may not correspond with the colors of the wires in your ...

Страница 13: ...Appliance dimensions 3 3 8 20 3 16 14 3 16 19 5 16 3 1 16 Appliance dimensions 13 ...

Страница 14: ...ie KM 93 2 combinations 23 16 195 16 23 16 Depth in mm Width Dimen sion B in mm 2 zone Combiset 1 combiset 2 combisets 3 combisets 4 combisets 5 combisets 490 490 490 490 490 265 558 851 1144 1437 4 zone Combiset 1 combisets 2 combisets 3 combisets 490 490 490 560 1143 1728 Combination One 2 zone one 4 zone Two 2 zone one 4 zone Three 2 zone one 4 zone One 2 zone two 4 zone Two 2 zone two 4 zone 4...

Страница 15: ...trac tor and connect the appliance to the power supply When installing more than one com biset a stainless steel spacer bar must be placed between units It is supplied with its own installation instructions Depth in inches Width Dimen sion B in inches 2 zone Combiset 1 combiset 2 combisets 3 combisets 4 combisets 5 combisets 19 5 16 19 5 16 19 5 16 19 5 16 19 5 16 10 7 16 22 33 1 2 45 1 16 56 9 16...

Страница 16: ...Installation should only be per formed out by a suitably qualified and trained person The exhaust ducting should be as short and straight as possible The use of angled pipes should be avoided as this will reduce the air flow of the extractor Only use ducting made of non flammable material The exhaust ducting may be angled either to the left right or downwards If the ducting is run beneath the cabi...

Страница 17: ...ner beneath the oil drain valve An opening of at least 135 mm 5 5 16 diameter must be cut in the kitchen cabinet in order to allow the exhaust ducting to pass through Mount the fan so that the impeller cannot be inadvertently reached by hand The exhaust ducting should be at tached to the exhaust connection using the supplied hose clamp E 10 1 4 5 1 2 F 13 5 1 8 D 7 1 2 8 1 4 Exhaust connections 17...

Страница 18: ...tions in temperature the problem of sweating or condensation will have to be addressed The exhaust ducting may need to be in sulated Example Wall vent 1 Flexible 90 bend 2 Flexible pipe 3 Flexible 45 bend 4 1 1 m 0 3 m 1 0 m 0 2 m 43 12 39 8 Total pipe length 2 6 m 81 2 With a total pipe length of 81 2 ft 102 the exhaust is within the effec tive range Air flow rates Setting 1 240 m3 h 145 CFM Sett...

Страница 19: ...19 ...

Страница 20: ...Alteration rights reserved 22 001 CDN USA 4698 ...

Отзывы: