background image

The filters should be regularly
cleaned, or changed, as appropri-

ate. 
Saturated filters are a fire hazard.

Under no circumstances use a
steam cleaner to clean this ap-

pliance. 
Pressurised steam could give rise to a
short circuit or cause permanent dam-
age to the surface and components, for
which the manufacturer of the cooker
hood cannot accept any responsibility.

In countries where there are areas
which may be subject to infesta-

tion by cockroaches or other vermin,
pay particular attention to keeping the
appliance and its surroundings in a
clean condition at all times. Any dam-
age which may be caused by cock-
roaches or other vermin will not be
covered by the appliance guarantee.

Installation

The distance between the top of
the hob and the bottom of the

cooker hood must measure at least:

– 45 cm above electric hobs
– 65 cm above gas hobs

The distance of 65 cm between
the cooker hood and a gas hob is

a minimum, which is only permissible if
the nominal heat ratings given in the fol-
lowing table are not exceeded:

Gas cooker

maximum

nominal rating

one burner

2.7 kW

all burners

7.5 kW

oven

3.5 kW

Gas hob

maximum 

nominal rating

one burner

3.5 kW

all burners

10.3 kW

Gas hob with ceramic cover plate

The data given for the maximum nominal (heat)
ratings do not apply to a gas hob with a ceramic
cover plate. In this case it is essential to refer to
the hob manufacturer’s data. 

Safety regulations prohibit the fit-
ting of a cooker hood over solid

fuel stoves.

All ducting, pipework and fittings
must be of non-flammable ma-

terial.  These can be obtained from the
Miele Spare Parts department or from
builders’ merchants.

The appliance must not be con-
nected to a chimney or vent flue

which is in use.  Neither should it be
connected to ducting which ventilates
rooms with fireplaces.

If exhaust air is to be extracted into
a chimney or ventilation duct no

longer used for other purposes, take
professional advice.

Warning and safety instructions 

6

Содержание DA 68

Страница 1: ... instructions for cooker hood DA 68 DA 68 EXT It is essential to read these operating instructions before Q installing or using the machine to avoid the risk of accident or damage to the machine M Nr 05 035 290 ...

Страница 2: ...ons 10 Cleaning and care Housing 11 Grease filter 11 Active charcoal filters 12 Changing the compact light or starter 13 After sales service 14 Electrical connection 15 Technical data 16 Appliance dimensions 17 Installation Fitting the non return cap 18 Fitting the adaptor 18 Building in 19 Removing the appliance 19 Connection for air extraction 20 Connection for air recirculation 22 Connection to...

Страница 3: ... away please ensure they are of fered for recycling Disposal of your old appliance Old appliances contain materials which can be reclaimed or recycled Please contact your dealer your waste collec tion centre or scrap merchant about potential recycling schemes Ensure that the appliance presents no danger to children while being stored for disposal See the appropriate sec tion in the Warning and Saf...

Страница 4: ...ance of these instructions Technical safety Before connecting the cooker hood to the mains supply make sure that the voltage and frequency de tails given on the data plate corre spond with the on site electricity sup ply If in doubt consult a qualified electrician The electrical safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective eart...

Страница 5: ...e cooker hood To avoid the danger of fire do not flambé or grill dishes When switched on the cooker hood could draw flames into the filter Fat particles drawn into the cooker hood present a fire hazard When using the cooker hood over a gas hob ensure that any burners in use are always covered by a pan otherwise flames could be drawn up by the suction of the cooker hood parts of which could then be...

Страница 6: ...en the cooker hood and a gas hob is a minimum which is only permissible if the nominal heat ratings given in the fol lowing table are not exceeded Gas cooker maximum nominal rating one burner 2 7 kW all burners 7 5 kW oven 3 5 kW Gas hob maximum nominal rating one burner 3 5 kW all burners 10 3 kW Gas hob with ceramic cover plate The data given for the maximum nominal heat ratings do not apply to ...

Страница 7: ...r can only be switched on when the heating appliance is switched off or vice versa NB The overall ventilation condition of the dwelling must be taken into ac count If in any doubt the advice of a competent builder or for gas a Corgi installer must be sought If the cooker hood is operated in recir culation mode only with active char coal filters these restrictions do not apply Only for appliances w...

Страница 8: ...f the appliance b Sliding switch for hob lighting c Sliding switch for the fan d Sliding switch for the power setting e Grease filter f Grease filter retaining clip g Lighting for hob Description of the appliance 8 ...

Страница 9: ...ow to medium level is usually enough For frying or cooking food with a strong aroma the IS intensive level is recommended To operate Set the sliding switch for the fan at 1 After cooking If the air still needs to be cleared after cooking we recommend letting the cooker hood continue to run for a fur ther ten minutes To switch off Set the sliding switch for the fan at 0 Switching the lighting on an...

Страница 10: ...r the cooking smells to be blown di rectly outside Air recirculation The air is drawn in and cleaned first by the grease filter In addition it is then cleaned by the two active charcoal fil ters The cleaned air is then recircu lated back into the kitchen through a vent in the top of the cooker hood Before using the cooker hood for the first time ensure that the active charcoal filters are in place...

Страница 11: ...a little mild detergent has been added Dry using a soft cloth Never use cleaning agents contain ing soda acids chlorides or ab rasive substances as these can damage the surface material Grease filter The re usable metal grease filter in the appliance removes solid particles from the kitchen vapours grease dust etc preventing soiling of the cooker hood Clean the grease filter when it looks dirty an...

Страница 12: ...cessible hous ing to prevent the risk of these catch ing fire When putting the grease filter back ensure that the retention clip faces to wards the hob Should the filter be replaced upside down insert a small screwdriver blade into the slits to disengage the clip Do not let the filter fall on to the hob below Active charcoal filters If the cooker hood is connected for air recirculation two active ...

Страница 13: ...ble Ensure curent is not restored to the appliance while maintenance or re pair work is being carried out Unscrew the fixing screws on the glass cover holders When doing this push the glass cover upwards so that it does not fall on the hob surface Take off the glass cover holders Take out the glass cover guiding it downwards at an angle Carefully swivel the light tube out of the bracket downwards ...

Страница 14: ...t Your Dealer or Your nearest Service Dept see address on the back page When contacting the Service Depart ment please quote the Model and Ser ial number of your machine appliance both of which are given on the data plate which is visible on removing the grease filter s After sales service 14 ...

Страница 15: ...cted to the termi nal in the plug which is marked with the letter E or by the earth symbol z or col oured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red WARNING THIS APPLIANCE MUST BE EA...

Страница 16: ... rating IRL ZA 10 A Connection cable 1 5 m Fan power Air extraction system ø 125 mm Air extraction according to DIN 44971 Extraction Level 1 3 190 390 m3 h Level IS 500 m3 h Recirculation Level 1 3 160 255 m3 h Level IS 300 m3 h unrestricted Level 1 3 230 410 m3 h Level IS 540 m3 h Electrical connection 16 ...

Страница 17: ...Appliance dimensions Appliance dimensions 17 ...

Страница 18: ...g the non return flap for air extraction mode only not for EXT models Locate the non return flap in the ex haust socket so that you can open the flaps upwards Turn the non return flap slightly anti clockwise to secure it Fitting the adaptor not for EXT models Take the largest adaptor possible The larger the diameter the higher the exhaust suction and the quieter the running noise Put one of the ad...

Страница 19: ...y out the further connection for air extraction or for recirculation Finally insert the plug into the elec tricity supply socket Removing the appliance Disconnect the cooker hood from the electricity supply by removing the plug and with EXT models removing the connector for the lead to the ex ternal fan Remove the extraction ducting from the exhaust stub Unscrew the fixing screws and remove the co...

Страница 20: ... be less than 100 mm The use of flat ducting also reduces the air extraction efficiency The use of extraction ducting with a diameter of less than 100 mm and of flat ducting increases the noise level of the cooker hood Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connect...

Страница 21: ... to be addressed In addition to suitable insulation for the exhaust ducting we recommend the in stallation of a condensate trap which will collect the water and evaporate it Condensate traps are available from Miele Spare Parts department Please note that the condensate trap should be installed vertically and as directly above the exhaust socket of the cooker hood as possible Connection for air ex...

Страница 22: ...ectional grille through the hole in the unit onto the exhaust connection of the cooker hood so that the air out let points in the desired direction NB on no account should it point to wards the wall Screw the directional grille to the unit with two screws If a panel is to be used to extend the wall unit or the cooker hood shaft to the ceiling a suitable cutout must be made in the panel Connection ...

Страница 23: ...125 mm diameter As an alterna tive to this an exhaust ducting of 150 mm diameter can be purchased and connected In this case use a sharp knife to cut off the exhaust stub at the join The non return flap is integrated with these models Electrical connection is made via a con necting lead with plug and coupling Separate fitting instructions are sup plied with the external fan Connection to an extern...

Страница 24: ...Alteration rights reserved 001 D 0998 This paper consists of cellulose which has been bleached without the use of chlorine ...

Отзывы: