Electrical connection
89
Hardwired electrical connection
It is possible to hardwire this appliance
to an existing power cable.
CAUTION: Before servicing, discon‐
nect the power supply by either re‐
moving the fuse, shutting off the
power main or manually "tripping"
the circuit breaker.
Installation work and repairs should
only be performed by a qualified
technician in accordance with all ap‐
plicable codes and standards. Re‐
pairs and service by unqualified per‐
sons could be dangerous and the
manufacturer cannot be held re‐
sponsible.
Before connecting the appliance to
the power supply, make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply. This da‐
ta must correspond to prevent ma‐
chine damage. Consult an electrician
if in doubt.
GROUNDING INSTRUCTIONS
THIS APPLIANCE MUST BE
GROUNDED.
This appliance must be connected to a
grounded metal, permanent wiring sys‐
tem, or an equipment-grounding con‐
ductor must be run with the circuit con‐
ductors and connected to the equip‐
ment-grounding terminal or lead on the
appliance.
Prior to making a hardwire connec‐
tion to the terminal, remove the pow‐
ercord. Otherwise there will be a risk
of electric shock from the attached
plug.
An existing flexible supply cord or cable
shall have a minimum thickness of
AWG 14.
120 V, 60 Hz, 15 A fuse rating
Black wire (live): connect to L
White wire (neutral): connect to N
Green wire (ground): connect to
After attaching the permanent power
supply cord, check that all screws on
the terminal block and the strain re‐
lief are tightened.