background image

In the event of a fault which you cannot
correct yourself, or if the appliance is
under guarantee, please contact:

– your Miele Dealer

or

– the Miele Service Department

(see back cover for contact details).

When contacting the Service
Department, please quote the model
and serial number of your appliance
These are shown on the data plate
which is visible when the vapour plates
are removed.

Please note that telephone calls may
be monitored and recorded for
training purposes.

After sales service

36

Содержание DA 489-4

Страница 1: ...ion instructions Cooker hood DA 489 4 DA 489 4 EXT To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time GiWOZ M Nr 06 958 270 ...

Страница 2: ... Housing 19 General notes 19 Important for appliances with stainless steel housing 19 Vapour plates and grease filter 20 Glass surfaces 23 Fitting and replacing the charcoal filter 23 Changing the halogen lamps 25 Appliance dimensions 26 Safety distance between hob and cooker hood S 27 Installation 28 Connection for air extraction 31 Condensate trap 32 Silencer 32 Electrical connection 33 Operatio...

Страница 3: ...als which if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Please do not therefore dispose of your old appliance with your household waste Please dispose of it at your local community waste collection recycling centre and ensure that it presents no danger to children ...

Страница 4: ...ectrician if in any doubt The electrical safety of this appliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national safety regulations It is most important that this basic safety requirement is present and tested regularly and where there is in any doubt the household wiring system should be inspected by...

Страница 5: ...od To avoid the danger of fire do not flambé or grill over an open flame under the cooker hood When switched on the cooker hood could draw flames into the filter Fat particles drawn into the cooker hood present a fire hazard When using the cooker hood over a gas hob ensure that any burners in use are always covered by a pan Switch the cooking zone off when a pan is removed even for a short time Re...

Страница 6: ...ling film polystyrene and plastic wrappings must be kept out of the reach of babies and young children Danger of suffocation Dispose of or recycle all packaging safely as soon as possible Installation The distance betwen the top of the cooker hob and the bottom of the cooker hood glass canopy must measure at least 350 mm unless a greater distance is specified by the manufacturer If more than one a...

Страница 7: ...e starved of oxygen impairing combustion Harmful gases could be drawn out of the chimney or extraction ducting back into the room with potentially fatal consequences In order to ensure safe operation and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously an underpressure in the room of 0 04 mbar...

Страница 8: ...take fan or open a motorised inlet flap when it is switched on The cooker hood can be set up to automatically switch off a heating appliance which also depends on the air from the room when it is switched on The Miele DSM 400 control module offers the possibility of combining other components with the cooker hood see Operation with Control module DSM 400 It is available to purchase as an optional ...

Страница 9: ...conversion kit and charcoal filter see Technical Data The air is drawn in and cleaned first by the vapour plates and the grease filter and then by a charcoal filter The cleaned air is then recirculated back into the kitchen through grilles in the top of the cooker hood extension piece Charcoal filters are available to order through your Dealer or the Miele Spare Parts Department See back cover for...

Страница 10: ...Guide to the appliance 10 ...

Страница 11: ...ontrol lights up when the vapour plates and grease filter need to be cleaned The touch control is used to reset the operating hours counter every time the grease filter and vapour plates are cleaned see Cleaning and care It can also be used to check and alter the operating hours counter oTouch control for the charcoal filter The indicator lamp for the charcoal filter lights up when the charcoal fi...

Страница 12: ... to III green indicator lamps are usually sufficient for normal cooking Intensive setting When frying or cooking food with a strong aroma you may wish to select the Intensive setting level IV yellow indicator lamp for a short period Automatic switch off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III To set ...

Страница 13: ...sable to run the fan for a few minutes after cooking has finished to neutralise any lingering odours in the air whether you are using air extraction or recirculation mode The fan can be set to switch off automatically after either 5 or 15 minutes After cooking has finished press the run on option control whilst the fan is still running Press once The fan will switch off after 5 minutes left hand i...

Страница 14: ...ol in The brightness will gradually dim until you release the control Press the control in again to increase the brightness to the level required and then release it If you keep the control pressed in the light will continually change between bright and dim To switch the hob lighting off Press the hob lighting control briefly to switch the lighting off The indicator lamp will go out Safety cut out...

Страница 15: ...ours counter must be reset To do this press and hold the grease filter control for approx 3 seconds while the fan is switched on The indicator lamp for the control will go out Reading the grease filter operating hours counter To check the percentage of time set already used Press the On Off control to switch the fan on Press and hold the grease filter control One or more of the indicator lamps for...

Страница 16: ...the filter and make cleaning more difficult Press the On Off control to switch the fan off Press the run on option control and the grease filter control at the same time The indicator lamp for the grease filter control and one of the indicator lamps will flash The indicator lamps show the time which has been set 1st lamp from the left 20 hours 2nd lamp from the left 30 hours 3rd lamp from the left...

Страница 17: ...the charcoal filter controls at the same time The indicator lamp for the charcoal filter control and one of the lamps above the controls will flash The control lamps show the time which has been set 1st lamp from the left 120 hours 2nd lamp from the left 180 hours 3rd lamp from the left 240 hours 4th lamp from the left deactivated Use the controls to select the desired time Confirm the selection b...

Страница 18: ...he fan is switched on The indicator lamp for the control will go out Reading the charcoal filter operating hours counter To check the percentage of time set already used Press the On Off control to switch the fan on Press and hold the charcoal filter control One or more of the indicator lamps for the controls will flash The number of flashing lamps shows the percentage of the operating time which ...

Страница 19: ...ng soda acids chlorides or solvents abrasive cleaning agents e g powder cleaners or cream cleaners and abrasive sponges as well as pot scourers or sponges which have been used previously with abrasive cleaning agents These will damage the surface material Please observe the instructions below for cleaning the stainless steel housing the controls and glass surfaces Important for appliances with sta...

Страница 20: ...ting off and allow to cool down before removing the vapour plates to avoid any risk of burning yourself on the lighting To avoid damaging the filter or the hob below make sure you hold the filter securely at all times when handling it First remove the vapour plate in the middle To do this pull the vapour plate out of its holder at the bottom 1 then press on the top and bring it down to remove it 2...

Страница 21: ... pH value higher than 7 such as powder cleaners cream cleaners or abrasive all purpose cleaning agents oven sprays Cleaning the grease filter in the dishwasher Place the filter with the short side upright in the lower basket and wash in a 65 programme using a mild dishwasher detergent ensuring the spray arm is not obstructed Avoid alkaline dishwasher detergents with a pH value higher than 7 Depend...

Страница 22: ...lace at the bottom Fit the middle vapour plate into the slots at the top 1 then click into place at the bottom 2 After replacing the grease filter press the grease filter control for approx 3 seconds to reset the operating hours counter The indicator lamp will go out If the vapour plates and grease filter are cleaned before the operating hours counter has reached its maximum the grease filter touc...

Страница 23: ...eplacing the charcoal filter If the cooker hood is connected for recirculation a charcoal filter must be inserted in addition to the grease filter This is designed to absorb cooking odours It is fitted in the canopy above the grease filter New filters can be purchased from your Miele dealer or from the Miele Spare Parts Department See back cover for contact details and Technical data for the model...

Страница 24: ...ast every 6 months Used charcoal filters can be disposed of with the normal household waste After fitting the new charcoal filter press the charcoal filter touch control for approx 3 seconds to reset the operating hours counter The charcoal filter indicator lamp will go out If the charcoal filter is replaced before the operating hours counter has reached its maximum the charcoal filter touch contr...

Страница 25: ... surface and damage it Please follow the manufacturer s instructions Remove the cover to the lamp To do this loosen the screws to the left and right of the cover unhook the lamp cover and take it downwards and off To avoid damaging the lighting or the hob below make sure you hold the lamp cover and halogen lamps securely at all times when handling them Pull the halogen lamp out of its socket Gentl...

Страница 26: ...s The shaded area represents the wall or ceiling area for the vent cut out for fitting the connection socket and on EXT models for feeding the connection cable through to the external motor For recirculation mode only a connection socket needs to be fitted Connection for air extraction C 150 mm or C 125 mm with reducing collar Appliance dimensions 26 ...

Страница 27: ...ety instructions Account should also be taken of the height of the person who will be using the hood most often The person should have sufficient space to work comfortably at the hob and also be able to reach the hood controls with ease If positioned too high extraction will be inefficient If you want the top of the cooker hood to be mounted flush with the ceiling make sure there is adequate space...

Страница 28: ...Assembly parts Installation 28 ...

Страница 29: ...ble aluminium hose the conversion kit is not supplied with the cooker hood but is available as an optional extra See Technical data Installation instructions 8 large headed screws 5 x 40 mm and 8 x S 8 plugs for securing the retaining plates and the appliance unit The screws and plugs are designed for use in solid walls For other types of wall construction alternative fixings will be required Make...

Страница 30: ...ion sheet for instructions on how to install this appliance Protective foil on stainless steel appliances Some of the housing components have protective foil around them to prevent them being damaged during transport Please remove this foil before fitting the housing components It can be peeled off easily Dismantling Should the appliance ever need to be dismantled follow the installation instructi...

Страница 31: ...s than 150 mm or if flat ducting is used the noise level of the cooker hood will increase and extraction will be less efficient Only reduce the diameter of the ducting if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable materi...

Страница 32: ...ect and evaporate any condensate which may occur Condensate traps are available for C 125 mm or C 150 mm ducting When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection The arrow on the housing indicates the direction of air flow Silencer optional accessory for EXT models only To achieve even further reductions in noise levels...

Страница 33: ...ble isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and relays according to EN 60 335 If the switch is not accessible after installation depending o...

Страница 34: ...he room through an open window that ventilation is not impaired by a closed blind or curtain If the control module is disconnected in order to operate the cooker hood without the window contact switch e g after moving house the cooker hood electronics must be reset by a Miele service technician Potential free connection This enables a further appliance to be controlled by the switch setting on the...

Страница 35: ... Installation The tower needs to be removed before the control module can be fitted to the fan unit A fixing bracket is required for fitting the control module This is available as an optional accessory M Nr 8363350 The control module is supplied with its own detailed operating and installation instructions Operation with DSM 400 control module 35 ...

Страница 36: ...Service Department see back cover for contact details When contacting the Service Department please quote the model and serial number of your appliance These are shown on the data plate which is visible when the vapour plates are removed Please note that telephone calls may be monitored and recorded for training purposes After sales service 36 ...

Страница 37: ...raction system C 125 mm Level I 180 m3 h Level II 280 m3 h Level III 380 m3 h Level IV Intensive Setting 580 m3 h Unrestricted 690 m3 h Recirculation with charcoal filter Level I 150 m3 h Level II 210 m3 h Level III 330 m3 h Level IV Intensive Setting 490 m3 h Special accessory for recirculation mode Conversion kit DUW 20 Miele charcoal filter DKF 12 For EXT models the connected load and extractio...

Страница 38: ...38 ...

Страница 39: ...39 ...

Страница 40: ...Alteration rights reserved 3906 M Nr 06 958 270 00 gb GB ...