manualshive.com logo in svg
background image

Installation

28

Installation recommendations

– We also recommend a distance of at

least 25 ¹/₂" (650 mm) above electric

cooktops to provide more workspace

and easier cooking under the hood.

– When selecting an installation height,

always take the user height into

consideration. Users should have

ample space to work comfortably on

the cooktop and reach the ventilation

hood controls with ease.

– Please note that the greater the

distance from the cooktop, the less

effective the hood is at drawing in the

cooking vapors.

– To achieve optimal vapor extraction,

make sure that the hood covers the

cooktop. The hood should be

positioned centrally over the

cooktop, not to the side or rear.

– The cooktop should be no wider than

the hood. Preferably, it should be

narrower.

– The mounting area must be easily

accessible. The ventilation hood

should be easy to reach and

disassemble in case a service call is

necessary. This should be taken into

consideration when planning the

position of cupboards, shelves,

ceilings or decorative elements in the

vicinity of the ventilation hood.

Drilling diagram for wall

mounting

When drilling, please follow the

directions contained on the

accompanying installation sheet.

When installing a custom back wall

with pre-drilled holes, please refer to

the drilling distances in the drawing

above (screws 

 ³/₁₆" (5 mm)).

* The dimension for the middle wall

bracket is variable. It will depend on the

position of the wall vent and the socket.

It should be set as low as possible.

Содержание DA 399-6

Страница 1: ...s DA398 6 DA399 6 en CA Installation repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions ...

Страница 2: ...installing the housing components It can be peeled off easily without any additional tools Installation Instructions Please refer to the accompanying installation sheet for instructions on how to install the appliance Disassembly If the device ever needs to be disassembled follow the installation sheet instructions in reverse order A lever is provided to assist with the removal of the chimney Unsc...

Страница 3: ...Installation 24 Installation parts ...

Страница 4: ...for recirculation mode contains diverter aluminum hose and hose clamps not contained in scope of delivery available as optional accessory see Technical Data 8 screws x 2 5 x 60 mm 8 plugs x 2 8 x 50 mm for attaching to the wall not for use in USA CDN The screws and plugs are designed for use in solid walls only Use different fasteners for other wall construction types Make sure that the wall can s...

Страница 5: ...Installation 26 Appliance dimensions The drawing is not to scale a Extraction b Recirculation c Air vent positioned at top for recirculation ...

Страница 6: ...tion contained in the IMPORTANT SAFETY INSTRUCTIONS section Minimum distance S Cooking appliance Miele appliance Non Miele appliance Electric Induction cooktop 24 610 mm Electric grill deep fat fryer electric 26 660 mm Multi burner gas cooktop 43 000 BTU hr 12 6 W no burner 15 000 BTU hr 4 5 kW 26 660 mm 30 760 mm Multi burner gas cooktop 73 800 BTU hr 21 6 W no burner 16 500 BTU hr 4 8 kW 30 760 ...

Страница 7: ...r the cooktop not to the side or rear The cooktop should be no wider than the hood Preferably it should be narrower The mounting area must be easily accessible The ventilation hood should be easy to reach and disassemble in case a service call is necessary This should be taken into consideration when planning the position of cupboards shelves ceilings or decorative elements in the vicinity of the ...

Страница 8: ...Installation diagram To install a plywood backing Determine and mark the location of the retaining plate for the canopy as outlined on the Installation diagram Make a cutting line 3 76 mm above and 3 76 mm below the outline of the retaining plate Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line along the center of...

Страница 9: ...t be smaller than that of the exhaust connector The exhaust duct should be as short and straight as possible If elbows are needed make sure they have a large radius The exhaust duct itself must not be kinked or compressed Make sure that all connections are secure and airtight Remember that any constriction of the airflow will reduce extraction performance and increase operating noise If the exhaus...

Страница 10: ...sitioned vertically and if possible directly above the hood outlet duct collar The arrow on the housing indicates the direction of airflow Reducing Collar optional accessory If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed It reduces the air flow to less than 400 CFM Check local building codes for max CF...

Страница 11: ...ult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED The hood comes equipped with a power cord with a NEMA 5 15 molded plug for connection to a 120 VAC 60 Hz 15 A power outlet Grounding Instructions WARNING Improper grounding can result in a risk of electric shock This appliance must be grounded In the event of an electrical short circuit ...

Страница 12: ...Technical Service Department is listed at the back of these instructions When contacting Miele please state the model and serial number of your ventilation hood These can be found on the data plate Location of the data plate The data plate is visible once you have removed the grease filters Warranty For further information please refer to your warranty booklet ...

Страница 13: ...l connected load 450 W Voltage Frequency 120 V AC 60 Hz Fuse rating 15 A Power cord length 2 5 ft 0 75 m Weight DA 398 6 55 3 lbs 25 1 kg DA 399 6 57 2 lbs 26 kg Optional accessories for recirculation mode Recirculation kit DUW 20 and OdorFree Charcoal Filter DKF 12 ...

Страница 14: ...e Canada Importer Miele Limited Headquarters and Miele Centre 800 843 7231 609 419 9898 609 419 4298 Technical Service Support Nationwide Phone Fax TechnicalService mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca 800 999 1360 888 586 8056 Customer Care Centre Phone customercare miele ca 800 565 6435 905 532 2272 Germany Manufacturer Miele Cie KG Carl Miele Straße 29 33332 Güters...

Страница 15: ...M Nr 09 968 240 02 en US DA 398 6 DA 399 6 ...

Отзывы: