Reading the operating hours counter
for the charcoal filter
To check the percentage of time set
already used:
^
Press the On/Off control to switch the
fan on.
^
Press and hold the charcoal filter
control.
One or more of the indicator lamps for
the
-
/
+
controls will flash.
The number of flashing lamps shows
the percentage of the operating time
which has already been used up.
1 lamp
=
25 %
2 lamps
=
50 %
3 lamps
=
75 %
4 lamps
= 100 %
The number of operating hours used
remains in the memory, even when the
appliance is switched off or there is a
power cut.