![Miele DA 262 i Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/miele/da-262-i/da-262-i_operating-instructions-manual_237023008.webp)
Installation
The distance between the top of
the hob and the bottom of the
cooker hood (when the vapour guide is
completely retracted) must measure at
least:
– 45 cm above electric hobs
– 65 cm above gas hobs.
(
Australia:
60 cm for electric and gas
hobs)
Only for U.K.:
The distance of
65 cm between the cooker hood
and a gas hob is a minimum, which is
only permissible if the nominal heat
ratings given in the table below are not
exceeded:
Gas cooker
maximum
nominal rating
one burner
2.7 kW
all burners
7.5 kW
oven
3.5 kW
Gas hob
maximum
nominal rating
one burner
3.5 kW
all burners
10.3 kW
Gas hob with ceramic cover plate
The data given for maximum nominal (heat)
ratings do not aply to a gas hob with a ceramic
cover plate. In this case it is essential to refer to
the hob manufacturer’s data.
Safety regulations prohibit the fit-
ting of a cooker hood over solid
fuel stoves.
All ducting, pipework and fittings
must be of non-flammable ma-
terial. These can be obtained from the
Miele Spare Parts department or from
builders’ merchants.
The appliance must not be con-
nected to a chimney or vent flue
which is in use. Neither should it be
connected to ducting which ventilates
rooms with fireplaces.
If exhaust air is to be extracted into
a chimney or ventilation duct no
longer used for other purposes, take
professional advice.
Warning and Safety instructions
8
Содержание DA 262 i
Страница 1: ...DA 262 i DA 272 i DA 292 i Q ä Operating instructions S Istruzione d uso M Nr 05 128 470 ...
Страница 50: ...50 ...
Страница 51: ...51 ...
Страница 52: ...Alteration rights reserved Salvo modifiche 44 000 GB AUS NZ ZA I 2998 ...