Connection for air extraction
39
Condensate trap
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur.
Condensate traps are available for
125 mm or 150 mm ducting.
When installing a condensate trap,
ensure that it is positioned vertically
and, if possible, directly above the
exhaust socket.
The arrow on the housing indicates
the direction of airflow.
The condensate trap will be integrated
in rangehoods which are designed to be
connected to an external motor
(...EXT models).
Silencer
To achieve even further reductions in
noise levels, a special silencer (optional
accessory) can be fitted in the ducting
system.
Air extraction mode
The silencer not only reduces noise
from the motor outside the house, but
also sounds from outside (e.g. traffic
noise). For this reason, the silencer
must be positioned as close as possible
to the ducting exit
.
Содержание DA 2510
Страница 14: ...Guide to the appliance 14 ...
Страница 32: ...Installation 32 Assembly parts ...
Страница 34: ...Installation 34 Appliance dimensions The drawing is not to scale ...
Страница 35: ...Installation 35 The drawing is not to scale ...
Страница 48: ...M Nr 10 572 860 03 en AU NZ DA 2550 DA 2570 DA 2510 DA 2550 EXT DA 2570 EXT ...