Reprograming the grease filter timer
The grease filter timer is preset to 30
hours. This time can be lengthend or
shortend to 20, 30, 40 or 50 hours.
– A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally. Otherwise grease
which has accumulated over a long
period of time will harden on the
filters making cleaning more difficult.
^
Press the On/Off button to turn off the
fan.
^
Press the Delayed Shut Down and
the grease filter buttons at the same
time.
The indicator for the grease filter and
one of the
_
indicators will flash.
The lit
_
indicator shows the
programmed time:
1
st
indicator from the left = 20 hours
2
nd
indicator from the left = 30 hours
3
rd
indicator from the left = 40 hours
4
th
indicator from the left = 50 hours
^
Use the
_
button to select the
desired time.
^
Store the selection by pressing the
grease filter button.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the “old”
data.