The shaded area represents the
wall or ceiling area for the vent
cut-out, for feeding the connection ca-
ble through to an external fan and for
fitting the connection socket.
(For recirculation mode the connection
socket may only be fitted in a wall
area).
Connection for air extraction
C
150 mm
or
C
125 mm with reducing collar.
Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
The
minimum safety distance
be-
tween the top of the cooker / hob
and the bottom of the cooker hood
should be at least
– 450 mm above an electric hob or
cooker,
– 650 mm above a gas hob or
cooker,
– 650 mm above an open grill
from our range.
See "Warning and Safety instruc-
tions" for further information.
A distance of 650 mm above electric
cookers / hobs may be preferable to
give more working space.
Dimension S
When deciding dimension
S
ensure
that the minimum specified safety dis-
tance between the hob / cooker and the
cooker hood is maintained. If the hood
is fitted flush to the ceiling make sure
that the remaining distance to the ceil-
ing is not greater or less than appliance
height
H
.
Extraction
H
= 734 – 984 mm
Recirculation
H
= 854 – 1084 mm
Appliance dimensions
25