![Miele CS 1028 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/miele/cs-1028/cs-1028_operating-and-installation-instructions_234178051.webp)
To check the first intake of air
e
Retaining nut
f
Air intake sleeve
Gap X
must
measure:
For Town Gas:
4 mm
For Natural Gas:
6 mm
For Liquid Petroleum Gas :
5 mm
If it does not:
– Loosen the retaining nut, adjust the
air intake sleeve, and tighten the
retaining nut again.
– Finally secure the jet against
inadvertent loosening with sealing
wax.
– Reassemble the hob in the reverse
order.
The flame must not go out on the lowest
setting, or when the control is turned
quickly from a high to a low setting.
On the highest setting the flame must
have a distinctive and visible core.
Conversion to another type of gas