Connection to the gas supply, or conversion from one type of gas to
another, should only be undertaken by an registered gas installer
employed
by Registered Gas Contractor
under the gas safety regulations (Registration
of Gas Installers and Gas Contractors).
When converting to a different type of gas, the main burner jet and the small
burner jets have to be changed.
Nominal rating at high setting
Gas type
kW
Town Gas (10 mbar)
Natural Gas (20 mbar)
Liquid Petroleum Gas (29 mbar)
8.00
8.00
7.50 / 546 g/h
Nominal rating at low setting
Gas type
kW
Town Gas (10 mbar)
Natural Gas (20 mbar)
Liquid Petroleum Gas (29 mbar)
1.8
1.8
1.8
Screw in the new jets according to the following table.
Jet table
Main jet*
C
Low setting jet
C
Town Gas
3.60
1.85
Natural Gas
2.00
0.92
Liquid Petroleum Gas
1.35
0.70
* The jet markings refer to 1/100 mm of the jet diameter.
Conversion to another type of gas
48