background image

Chapter 9: Settings

DSS-5000 

Email

Displays all entered email addresses.  Addresses 

can be added, edited, and deleted (Admin Only).  

Entered email accounts are added to the email 

address book.  Frequently used email addresses can 

be selected from the displayed address list rather 

than being re-typed each time.

Add Address

Server Settings

Edit Address

Address Book

Delete Selected 
Address

Send Test Email

Add Address (Admin Only)

1. Tap 

 to add an email address.

2. Use the displayed keypad to enter the contact name and

email address.

3. Tap Add to add the address to the email list or Cancel to

exit and return to the email list.

Edit Address (Admin Only)

1. Select a displayed email address by tapping it.
2. Tap 

 to edit the address.

3. Use the displayed keypad to edit the contact name and

email address.

4. Tap Add to add the address to the email list or Cancel to

exit and return to the email list.

Deleting An Address (Admin Only)

1. Select the email address by tapping it.
2. Tap

 to delete the address and tap Yes to confirm or 

Cancel to exit and return to the email list.

Server Settings

Enter and edit the email settings for sending outgoing email.
1. Tap 

 to access the email sever settings.

2. Tap 

 to enter or modify existing server settings includ-

ing Host, Port, Login, Password, SMTP Authorization, En-

able TLS, and From Email Address information.

3. Tap 

 to clear all server settings.

4. Tap 

 to return to the email Address Book.

User Settings (Admin Only)

Modify Usernames and Passwords..

Edit Users

User Settings

Delete Users

User Management

User Management (Admin Only)

1. Tap 

 to access User Management functions.

1. Tap 

 to display the current logged in Admin user.

2. Select a displayed user by tapping it.
3. Tap 

 to edit the Username, Password, and User Type 

(Standard or Admin).

4. Tap 

X

 when complete to return to the User Management

screen.

5. Tap 

 to delete the selected user and Yes to confirm.

Language Settings

Use the Language & Input function to select the 

default system language used by the tool.  User 

defaults also include Test Results, Email, and Print 

languages.

System Language

Select the default standard language for the analyzer to use on 

the Controller.

Test Result Language

Select the default language for the analyzer to use for all tests 

and results displayed on the Controller.

Email Language

Select the default standard language for the analyzer to use for 

all tests and results sent via email.

Print Language

Select the default standard language for the analyzer to use for 

all tests and results printed using a networked printer.

Содержание DSS-5000

Страница 1: ...Guide DSS 5000 Battery Diagnostic Service System For testing 6 and 12 volt automotive 12 volt and 24 volt charging systems...

Страница 2: ...iately with a mixture of water and baking soda Always wear proper safety glasses or face shield when working with or around batteries Keep hair hands and clothing as well as the analyzer cords and cab...

Страница 3: ...or updating and servicing the Control ler when a WiFi network is not available Power Supply Connection Tester Pod Accessory Connector Optional For connecting an optional accessory ex Amp Clamp DMM Cab...

Страница 4: ...er to a voltage source greater than 30 Vdc Connect the clamps to the tester the red clamp to the positive terminal and the black clamp to the negative terminal If you connect the clamps in the wrong p...

Страница 5: ...hen select from one of the displayed detected networks To manually add a network tap the plus sign again Follow the on screen instructions to select the Network SSID Security and IP Settings Tap Next...

Страница 6: ...le Test For testing out of vehicle customer batteries for possible return After New Battery Install For testing newly installed batteries in a vehicle Also includes vehicle electronics reset informati...

Страница 7: ...7 8 9 0 W E R T Y U P A S D F G H J K L Z X C V B N M Back Next Thedisplayeddigitcounterwillcountupthealphanumeric characters as they are being entered on the keypad Yr Make Model Use the scrolling l...

Страница 8: ...required standards Good Battery Unknown Reserve Battery meets or exceeds required standards Good Recharge Good Battery Battery is good but low on charge Fully charge the battery for optimal performan...

Страница 9: ...8V 7 86V 11 61V Cranking Current 623 9A 0A Send Results Done Test Results Starter Test Test Results Starter Decision Action Cranking Normal The starter voltage is normal and the battery is fully charg...

Страница 10: ...se or heavily corroded clean or replace the cable and retest HIGH OUTPUT Alternator voltage to the battery exceeds normal limits of a functioning regulator Check for loose and normal ground connection...

Страница 11: ...ng of CCA 100 to 3000 IEC A International Electrotechnical Commission 100 to 1000 EN A Europa Norm 100 to 1700 EN2 A Europa Norm 100 to 1700 Battery Rating Enter the Battery Rating Units value 4 Align...

Страница 12: ...el Use the scrolling lists to select the manufacture date manufacturer and vehicle model Once entered a list of matching previously tested vehicles is displayed Search Library 93 Vehicle Year 3 vehicl...

Страница 13: ...ttery meets or exceeds required standards Test again in 90 days or at next service opportunity Send Results System Test Done Test Results Battery 93 2005 Honda Civic 1HGEM225X5Lxxxxxx 4 10 2017 2 54 P...

Страница 14: ...If no Amp Clamp is being used begin the System Test at Step 4 2 Tap Continue to zero out the clamp or Skip if the Amp Clamp is not being used 3 With the engine and electrical loads off place the Amp...

Страница 15: ...when engine is running Check all alternator connections including to the battery Clean or replace if necessary and retest If the belts and connections are in good working condition replace alternator...

Страница 16: ...meter measures voltage between two points in a circuit The voltmeter is connected in parallel with the circuit AC Volt Meter 93 0 17 V AC 1 Connect the DMM test lead to the accessories port on the Dia...

Страница 17: ...ange and display the measurement 5 When finished press END 6 Tap Back to return to the Digital Multimeter screen Diode Drop The diode test measures the voltage drop across components such as diodes Di...

Страница 18: ...0 05 2 120 Vrms Vac 0 24 Vac rms 0 01 Vac 0 1 3 120 Vrms Adc 0 70 A 0 01 A 3 of reading 1A 1000 Arms 0 700 A 0 1 A 3 of reading 1A 1000 Arms Aac 0 70 A 0 01 A 3 of reading 1A 1000 Arms 0 700 A 0 1A 3...

Страница 19: ...Failed Replace Battery Aborted Badcell Short Replace Invalid Test Remote Post Aborted 24V Side Post Out Of Balance Totals By Test Type Displays test totals by test type HD Battery Pack Test After New...

Страница 20: ...include non critical Notifications Unread Critical Messages Read Critical Messages 1 Tap Messages on the Main Menu screen Messages 93 Critical 1 2 BMIS Authentication failed Check login credentials A...

Страница 21: ...WiFi Self Diagnostics WiFi Printer Self Diagnostics CVG Self Diagnostics Tester Pod Self Diagnostics Display Self Diagnostics Touchscreen Self Diagnostics WiFi Self Diagnostics Tests connectivity to t...

Страница 22: ...tup function detects and displays a list of connected and available WiFi and Bluetooth printers NOTE WiFi network communication must be suc cessfully established before a printer or printers can be de...

Страница 23: ...il sever settings 2 Tap to enter or modify existing server settings includ ing Host Port Login Password SMTP Authorization En able TLS and From Email Address information 3 Tap to clear all server sett...

Страница 24: ...Log into a BMIS account Shop Information Admin Only Access default Shop Information including Store Name address and phone number Also access battery test defaults including rating temperature units a...

Страница 25: ...d Add Tester Pod 1 Tap to add a device 2 Move the device to be linked within 30 feet of the Control ler turn on the device then tap 3 A list of detected devices is displayed Tap next to the desired de...

Страница 26: ...nostic Device Version CVG 2 Device Version No Device Configured OS Version Factory Preset Use this function to return the tool to the original as built configuration including all history and test set...

Страница 27: ...ation Single Battery or Dual Batteries Battery Application Automotive Marine Powersport Group 31 Commercial 4D 8D Lawn and Garden Battery Post Top Post Side Post Dual Post Test Location Top Post Side...

Страница 28: ...era Hold Steady Hold Controller steady when scanning the VIN barcode This allows the user to clearly see the bar code and allows the camera to focus on it Acquire VIN 93 Flashlight Fill the viewfinder...

Отзывы: