CPX-950
www.midtronicseurope.com
Midtronics BV Hoofdveste 6-8 3992DG Houten
24
25
8 – Maintenance & Troubleshooting
Appendix B: Test Results Decision Tables
CPX-950
Battery Test Results
Decision
Cranking
Health
Reserve
Capacity
SOH Message
Good
Battery
Good
Good
The battery shows good cranking performance. Test the battery again
at next service opportunity.
Good
Recharge
Good
Recharge
The battery shows good cranking performance but low charge.
Fully charge the battery for optimal performance and life. Check the
starting and charging systems for causes of low charge.
Charge &
Retest
Charge
and Retest
Charge the battery and retest to determine condition.
Replace
Battery
Good
Warning
The battery shows good cranking performance but low reserve
capacity performance. Low reserve capacity will compromise the
battery's ability to provide power to the vehicle and hold a charge
over time.
Good
Recharge
The battery shows good cranking performance but low charge
and low reserve capacity performance. Low reserve capacity will
compromise the battery's ability to provide power to the vehicle and
hold a charge over time. Check the starting and charging systems for
causes of low charge.
Charge
and Retest
The battery shows low charge and low reserve capacity performance.
Low reserve capacity will compromise the battery's ability to provide
power to the vehicle and hold a charge over time.
Warning
The battery shows low cranking performance. Replace the battery to
prevent a no-start situation in your vehicle.
Warning
The battery shows low cranking performance. Replace the battery to
prevent a no-start situation in your vehicle.
Frozen
Battery
Thaw the battery and retest. Do NOT charge the battery!.
Appendix B: Test Results Decision Tables
4.
Remove the discharged batteries.
5.
Insert new batteries as shown. Make sure the positive and negative terminals are positioned
correctly.
6.
Reposition the door on the battery compartment.
7.
Reinsert and tighten the screw.
Warning: Behind the AA batteries you find a sticker. Behind this a button cell is located, which once
removed means a recallibration is needed at a Midtronics Service Center.