background image

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

Page 

2

Quick Reference Guide

167-000840EN-B

October 2018

www.midtronics.com

Corporate Headquarters

 

Willowbrook, IL USA

 

Phone:          1.630.323.2800
Canadian Inquiries

 

Toll Free:            +1 1 866 592 8052

 

 

Midtronics b.v.

European Headquarters

Houten, The Netherlands 

 

Serving Europe, Africa, the Middle

East, and The Netherlands

 

Phone:               +31 306 868 150

 

Midtronics China

 

China Operations

 

Shenzhen, China

 

Phone:   +86 755 2374 1010

 

 

 

Midtronics India

Navi Mumbai, India

Phone:     +91 22 2756 4103/1513

 

 

Contact Corporate Headquarters

Phone:                 +1.630.323.2800

Asia/Pacífic (excluding China)

4.  Temperature

 - Hold sensor 6 to 12 inches over battery & se-

lect 

Capture

.

5.  VIN Capture

 - (optional) Scan VIN bar code, usually located 

in the right corner of the vehicle’s front windshield or on the 

driver’s side door frame.

Manual Entry

: Use the on-screen keypad to manually type 

the 17-digit VIN and tap 

Next

.

6.  Battery Test Setup

 - Edit vehicle and battery information 

based on the VIN & select 

Start

.

Application

Automotive, 4D/8D, Group 31

Battery Post

Top Post, Side Post

Battery Type

Flooded, EFB, AGM Spiral, AGM, Gel

Battery Units

CCA, MCA, CA, DIN, SAE, EN, EN2

Battery Rating Hold 

 or 

 to increase scrolling speed.

Battery Test Results

Send test results via 

email.

Continue to System 

Test

6

Print test results

Return to Main Menu

Icons are color-coded to indicate status.

  Battery Test

  Starter Test

  Alternator Test

Green:

All test parameters 

were completed and 

have passed.

Red:

The battery has 

failed the test.

Yellow:

Some test parameters 

may require further 

testing.

Gray:

Insufficent data to 

perform the test.

Refer to Appendix B: Decision Tables in the User Manual for a 

complete explaination of all possible test results.

System Test

1.  Start the vehicle’s engine and let it idle.
2.  Ensure all accessories (High Beam headlights/ventilation 

blower etc.) are off and select 

Next

.

The analyzer tests the alternator output.

3.  When prompted, rev and hold the engine to between 2000 

to 3000 rpm.
The analyzer tests the alternator output again.

4.  When prompted Idle the engine and and select 

Next

.

5.  Turn on the high beam headlights and ventilation blower.
6.  Select 

Next

.

The analyzer tests the alternator output.

7.  When prompted, rev and hold the engine to between 2000 

to 3000 rpm.
The analyzer tests the alternator output again.

8.  When prompted Idle the engine and and select 

Next

.

System Test Results

Test Results - Summary

Good Battery

Cranking Normal

Charging Normal

Send Results

Done

Test Results - Summary

The Test Results - Summary screen is displayed following a 

System Test.  Select the Battery, Cranking, or Alternator Test to 

view detailed test results for each part of the test.
To send the test results to a configured printer or via email select 

Send Results.  

To return to the Home Screen, select 

Done

 to the 

Main Menu.
Tap the icons at the top of the screen to view specific test results.
Refer to Appendix B: Decision Tables in the User Manual for a 

complete explaination of all possible test results.