Mido R718PA4 Скачать руководство пользователя страница 4

3

 

Power off

 

Remove DC12V adapter.

 

Note:

 

1.

At 1

st 

to 5

th 

second after power on, the device will be in engineering test mode.

2.

Remove and supply the power; the device is at off state by default. Need to be turned on to use.

3.

On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor

inductance and other energy storage components.

Network Joining

Never joined the network

 

Turn on the device to search the network to join.

 

The green indicator stays on for 5 seconds: success

 

The green indicator remains off: fail

 

Had joined the network

 

Turn on the device to search the previous network to join.

 

The green indicator stays on for 5 seconds: success

 

The green indicator remains off: fail

 

Fail to join the network

 

(when the device is on)

 

First two mins: wake up every 15 seconds to send request.

 

After two mins: enter sleeping mode and wake up every 15 minutes to send 
request. Note: Suggest to remove batteries if the device is not used to save power. 
Suggest to check the device verification information on the gateway or consult your 
platform server provider.

 

Function Key

Press and hold for 5 
seconds

 

Restore to factory setting / Turn off

 

The green indicator flashes for 20 times: success

 

The green indicator remains off: fail

 

Press once

 

The device is in the network: the green indicator flashes once and sends a report

 

The device is not in the network: the green indicator remains off

 

5. Data Report

The device will immediately send a version package report and a report data with temperature and humidity and voltage values. 

The device sends data in the default configuration before any configuration is done.

 

Maximum time: Max Interval

 

Note:

 

The real data sending cycle is programmed before shipment. There is no minimum time supported.

 

R718PA4 defaults Max Interval = 60min.

 

R718PA4 reports the hydrogen sulfide H

2

S concentration value.

 

The data parsing reported by the device is referenced by the 

MiDoMet

 LoraWAN Application Command document and 

www.midosmart.com

 

Report Configuration:

 

Description

 

Device

 

Cmd

 

ID

 

DeviceType

 

PayLoadData

 

ConfigReportRe 

q

 

R718PA4

 

0x01

 

0x57

 

MinTime(2bytes Unit:s)

 

MaxTime(2bytes 
Unit:s)

 

Reserved

 

ConfigReportRs 

p

 

0x81

 

Status(0x00_success)

 

Reserved (8Bytes,Fixed 0x00)

 

ReadConfigRepo 

rtReq

 

0x02

 

Reserved (9Bytes,Fixed 0x00)

 

ReadConfigRepo 

rtRsp

 

0x82

 

MinTime(2bytes Unit:s)

 

MaxTime(2bytes 
Unit:s)

 

Reserved

 

Report Configuration Example

:

 

(1) Report configuration parameters

Отзывы: