3
Power off
Remove DC12V adapter.
Note:
1.
At 1
st
to 5
th
second after power on, the device will be in engineering test mode.
2.
Remove and supply the power; the device is at off state by default. Need to be turned on to use.
3.
On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.
Network Joining
Never joined the network
Turn on the device to search the network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
Turn on the device to search the previous network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
(when the device is on)
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send
request. Note: Suggest to remove batteries if the device is not used to save power.
Suggest to check the device verification information on the gateway or consult your
platform server provider.
Function Key
Press and hold for 5
seconds
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
Press once
The device is in the network: the green indicator flashes once and sends a report
The device is not in the network: the green indicator remains off
5. Data Report
The device will immediately send a version package report and a report data with temperature and humidity and voltage values.
The device sends data in the default configuration before any configuration is done.
Maximum time: Max Interval
Note:
The real data sending cycle is programmed before shipment. There is no minimum time supported.
R718PA4 defaults Max Interval = 60min.
R718PA4 reports the hydrogen sulfide H
2
S concentration value.
The data parsing reported by the device is referenced by the
MiDoMet
LoraWAN Application Command document and
www.midosmart.com
Report Configuration:
Description
Device
Cmd
ID
DeviceType
PayLoadData
ConfigReportRe
q
R718PA4
0x01
0x57
MinTime(2bytes Unit:s)
MaxTime(2bytes
Unit:s)
Reserved
ConfigReportRs
p
0x81
Status(0x00_success)
Reserved (8Bytes,Fixed 0x00)
ReadConfigRepo
rtReq
0x02
Reserved (9Bytes,Fixed 0x00)
ReadConfigRepo
rtRsp
0x82
MinTime(2bytes Unit:s)
MaxTime(2bytes
Unit:s)
Reserved
Report Configuration Example
: