ENVIROMENTAL SPECIFICATIONS
Operating Temperature Range
-30
°
C / +60
°
C
Storage Temperature Range
-40
°
C / +85
°
C
Humidity
% 95, 50
°
C
ESD
IEC 801- 2KV
Water and Dust Protection
IP65, MIL-STD
MILITARY STANDARDS 810C/D/E/F
MIL-STD 810C
MIL-STD 810D
MIL-STD 810E
MIL-STD 810F
Method
Proc./
Cat.
Method
Proc./
Cat.
Method
Proc./
Cat.
Method
Proc./
Cat.
Low Pressure
500.1 I 500.2 II 500.3 II 500.4 II
High Temperature
501.1 I,
II 501.2
I/A1,
II/A1
501.3
I/A1,
II/A1
501.4
I/Hot,
II/Hot
Low Temperature
502.1 I 502.2
I/C1,
II/C2
502.3
I/C1,
II/C2
502.4
I/C1,
II/C2
Temperature
Shock
503.1 – 503.2
I/A1-C2
503.3
I/A1-C2
503.4
I/Hot-C2
Solar Radiation
505.1 II 505.2 I 505.3 I 505.4 I
Rain
506.1 I,
II 506.2 I,
II 506.3 I,
II 506.4 I,
III
Humidity
507.1 II 507.2 II 507.3 II 507.4 –
Salt Fog
509.1 – 509.2 – 509.3 – 509.4 –
Sand and Dust
510.1
I
510.2
I, II
510.3
I, II
510.4
I, II
Vibration
514.2
VIII/F,
XI/H
514.3 I/10, II/3 514.4 I/10, II/3 514.5 I/24, II/5
Shock
516.2
I, II
516.3
I, IV
516.4
I, IV
516.5
I, IV