20
RADIO PROGRAMMING
VX-350
:
For the VX-350 radio programming software CE-86 v1.01 or higher must be used.
Read the radio with the option board installed. Select “Common” from the menu and then “Option”. The “Option
Unit” should be read as “FVP-35”.
Under the “Common” heading select “Key Function” to set which key will control the Emergency ANI or Lone
Worker on/off. Program the desired button to “Option Switch” or “Option Switch 2”.
Download the program to the radio.
VX-410 & VX-420
:
For the VX-410 & VX-420 radio programming software CE-64 v1.00 or higher must be used.
Read the radio with the option board installed. Select “Common” from the menu and then “Option”. Set the
“Option Board” to “Encryption (Hi Level)”.
Under the “Common” heading select “Key Function” to set which key will control the Emergency ANI or Lone
Worker on/off. Set the “Side 1” or “Side 2” Key to “ACC 1”. Press or Press & Hold may be used. The assigned
button will then control the Emergency ANI. On full keypad versions the A, B, C, or D button may be used.
In the main screen, in the “ENCR” column, every channel must have the flag checked. NOTE: This does not
provide encryption on a per channel basis. On this screen, the “SQ” column must have a figure greater than “0”.
Download the program to the radio.
VX-450 & VX-460
:
For the VX-450 & VX-460 radio programming software CE-115 v1.01 or higher must be used.
Read the radio with the option board installed. Select “Common” from the menu and then “Option”. The “Option
Unit” should be read as “FVP-35”.
Under the “Common” heading select “Key Function” to set which key will control the Emergency ANI or Lone
Worker on/off. Set the mode select button to “Option Switch 1”.
Download the program to the radio.
VX-600 & VX-900
:
For the VX-600 & VX-900 radio programming software CE-39 v1.04 or higher must be used.
Read the radio with the option board installed. Select “Common” from the menu and then “Miscellaneous”. Set
the “Encryption Type” to “Hi Level”. This will also change the “Encryption Device” setting under “Common” >
“Option” to “Yes”.
Under the “Common” heading select “Key Function” to set which key will control the Emergency ANI or Lone
Worker on/off. Set the “TOP SEL Key” (top orange button), “SIDE SEL Key” (top side button), or the A, B, C, or D
(keypad models only) button to “ACC1”. The assigned button will then control the Emergency ANI.
In the main screen, in the “ENCR” column, every channel must have the flag checked. NOTE: This does not
provide encryption on a per channel basis.
Download the program to the radio.