12
HARDWARE INSTALLATION
Be certain to follow standard anti-static procedures when handling any of Midian’s products. Due to the design of
the options connector in the radio it is necessary to install two wires from the SVR-1-KW2 to the Kenwood radio.
PTT:
In order to be able to automatically key the radio it is necessary to install a wire from the point shown in the
picture below to a point in the radio as discussed in the installation instructions for the desired model radio.
COR:
In order to start recording the SVR-1 can look for COR or VOX. Midian recommends using COR rather than
VOX. COR is not brought up to the options connector so it is necessary to run a wire from the point shown in the
picture above to a point in the radio as discussed in the installation instructions for the desired model radio.
SVR-1-KW2 PTT Pad
Empty pad of R46
SVR-1-KW2 COR Pad