background image

 

 

 

 

 

 

 

 

(5)

 

Insert the all wires to the main PCB and install it inside the main body.

 

(6)

 

Install the back cover of the machine body with four screws..

 

(7) 

Install the LED PCB on the guide duct socket, place the wires in right place. 

(8) 

Connect the two plastic quick connectors and one metal component to the black wire, then place all 

wires correctly, install the handle cover to the machine cavity assembly. 

(9) 

Combine the machine cavity assembly and upcover assembly, fixed them three screws. 

(10) 

Place the key PCB on the switch bracket, then Install it into the hole. 

 

 

Содержание V19P13A20Q0C

Страница 1: ...020 This document is published to be used for after sales service only The content are subject to change without prior notice In interest of user safety the appliance should be restored to its origina...

Страница 2: ...Assembly Disassembly 6 2 2 1 Assembly of machine cavity 6 2 2 2 Assembly of Dust Cup 9 2 2 3 Disassembly 9 2 3 Error issue Trouble Shooting 9 2 3 1 Issue 1 Vacuum Cleaner Cannot Work 9 2 3 2 Issue 2...

Страница 3: ...y attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death There are special components used in this equipment...

Страница 4: ...til it clicks into place 2 Align the hand vacuum E with the top of the extension pole G and push down until it clicks into place The stick vac is now fully assembled and ready to use Note Different mo...

Страница 5: ...5 SERVICE 1 System Diagram 1 1 Components Note Different models have different components please refer to the instruction manual for specific models...

Страница 6: ...he seal ring on the battery pack bracket 2 Combine the motor assembly and the battery assembly 3 Install the seal ring on the motor and install it inside the machine cavity 4 Place the black wire in r...

Страница 7: ...7...

Страница 8: ...e duct socket place the wires in right place 8 Connect the two plastic quick connectors and one metal component to the black wire then place all wires correctly install the handle cover to the machine...

Страница 9: ...f assemble it 2 3 Error Issue Trouble Shooting 2 3 1 Issue 1 Vacuum Cleaner Cannot Work The power source is abnormal The circuit connection is loosen or short circuit N Tight the connection or change...

Страница 10: ...on can stop the vacuum cleaner The circuit connection is loosen or short circuit N Tight the connection or change the wire Y The PCB cannot work N The motor has circuit problems N Stop the vacuum clea...

Страница 11: ...ot tightly or broken There is block in the hose N Clean the hose Y There is block in the suction mouth N The temperature is too high N Reinstall the seal ring or replace a new one Y Clean the suction...

Страница 12: ...connection is loosen or short circuit N Tight the connection or change the wire Y The vacuum cleaner is used to clean liquid or metal materials N The motor is burnt N Change a new power source Y It s...

Страница 13: ...ver is broken or loose N Replace a new Dust bag cup Y Fix it tightly or replace a new front cover Y Note All maintenance should be done by professional engineers ATTACHED FILES LIST 1 Exploded View 2...