3.2.4 Service Guidance
E-6
Magnetron
1/2_6
Magnetron
over current
The current
measured by
the current
sensing
transformer
was outside
of tolerance.
Display error
message
Shorted
magnetron
E-8
Magnetron
1/2_8
Magnetron
current is too
low
The current
measured by
the current
sensing
transformer
was outside
of tolerance
Microwave
Inverter is
operating
above
temperature
Display error
message
13
Check the sensor
terminal CN7 is loose
Replug the
terminal
Change the
sensor
Change the
sensor
Replace the fuse 3
Replace the heater
Replace the
SRB relay
Replace the SSR
Reset the
thermostate
Change the
SRB
Change the
SRB
E17
E01
E02
The SRB
is bad
The SRB
is bad
The sensor
is bad
The sensor
is bad
Sensor Open
Check the thermostat
is reset
Check the SRB relay
RLY11 is normal
Check the SSR
terminal is normal
Check the heater
is normal
Check the fuse 3
is working
Sensor Short
Measure whether t
he sensor resistance
is normal
The temperature
of the cavity
is abnormal
Measure whether
the sensor resistance
is normal
Yes
Yes
Yes
Not
Not
Not
Not
Not
Not
Replace the
TFT or SRB
Replug the
terminal
CB
The TFT or SRB
is bad
The terminal
is loose
Abnormal
communication
Check the signal
wires of the
TFT Screen and
SRB(CN9)
is loose
Yes
Not
Not
Not
Содержание TJE17GS7-S00N0A
Страница 1: ...Commercial High Speed Oven SERVICE MANUAL TJE17GS7 S00N0A Oven Capacity 18 Liter 208 240v 60hz 6000w...
Страница 27: ...5 3 Overview View left hand side View right hand side 25...
Страница 28: ...View Baseplate side View Top side 26...
Страница 42: ...6 3 Circuit diagrams TJE17G S00N0A wiring diagram 208V 240 60Hz 40...
Страница 46: ......