Troubleshooting

 

Problem

Possible Causes

Dust is emitted from 
either the indoor or 
outdoor unit  

The unit may accumulate dust during extended periods of non-use, which 
will be emitted when the unit is turned on. This can be mitigated by covering 
the unit during long periods of inactivity.  

The unit emits a 
bad odor  

The unit may absorb odors from the environment (such as furniture, cooking, 
cigarettes, etc.) which will be emitted during operations. 
The unit’s filters have become moldy and should be cleaned.

The fan of the 

outdoor unit 

does not operate  

During operation, the fan speed is controlled to optimize product operation.

Troubleshooting Tips

When troubles occur, please check the following points before contacting a repair company. 

Problem

Possible Causes

Solution

The unit 
is not 
working 

Power failure

Wait for the power to be restored

The power switch is off

Turn on the power

The fuse is burned out

Replace the fuse

Remote control batteries are dead

Replace the remote control batteries

The unit’s 3-minute protection has 

been activated 

Wait three minutes after restarting the unit 

Poor cooling 
performance 

Temperature setting may be higher 

than the ambient room temperature  Lower the temperature setting
The heat exchanger on the indoor 

or outdoor unit is dirty 

Clean the affected heat exchanger

The air filter is dirty

Remove the filter and clean it according 

to instructions

The air inlet or outlet of either unit 

is blocked

Turn the unit off, remove the obstruction 

and turn it back on 

Doors and windows are open

Make sure that all doors and windows are 

closed while operating the unit 

Excessive heat is generated by 

sunlight

Close windows and curtains during 

periods of high heat or bright sunshine 

Low refrigerant due to leak or 

long-term use

Check for leaks, re-seal if necessary and 

top off refrigerant 

The unit 
starts and 
stops 
frequently 

There’s too much or too little 

refrigerant in the system  

Check for leaks and recharge the system 

with refrigerant  

There is air, incompressible gas or 

foreign material in the refrigeration 

system.  

Evacuate and recharge the system with 

refrigerant

System circuit is blocked

Determine which circuit is blocked and replace 

the malfunctioning piece of equipment 

The compressor is broken

Replace the compressor

The voltage is too high or too low

Install a manostat to regulate the voltage

Poor heating 
performance 

The outdoor temperature is lower 

than 7°C (44.5°F) 

Check for leaks and recharge the system 

with refrigerant 

Cold air is entering through doors 

and windows

Make sure that all doors and windows are 

closed during use  

Low refrigerant due to leak or 

long-term use

Check for leaks, re-seal if necessary and 

top off refrigerant 

Содержание QSBPQ4U-020AEN

Страница 1: ...NG TYPE AIR CONDITIONER Owner s Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Floor Standing Type ...

Страница 2: ...Indoor Unit Parts and Major Functions 05 Manual Operations 07 Table of Contents Owner s Manual SAFETY FIRST Safety Precautions 04 1 2 3 ...

Страница 3: ... a Unit Maintenance 08 b How to Clean the Air Filter 08 c Repairing Refrigerant Leaks 09 d Preparation for Periods of Non use 09 Troubleshooting 10 a Common Problems 10 b Troubleshooting Tips 11 European Disposal Guidelines 13 4 5 6 ...

Страница 4: ... may result in death The appliance must be installed in accordance with national regulations Failure to observe a caution may result in injury or equipment damage WARNING CAUTION DO NOT place items that might be affected by moisture damage under the indoor unit Condensation can occur at a relative humidity of 80 DO NOT expose heat producing appliances to cold air or place them under the indoor uni...

Страница 5: ...may malfunction or become less efficient COOL Mode HEAT mode DRY mode Indoor Temperature 17 32 C 62 90 F 0 30 C 32 86 F 17 32 C 62 90 F Outdoor Temperature 0 50 C 32 122 F 15 24 C 5 76 F 0 50 C 32 122 F 15 50 C 5 122 F low temperature cooling models Indoor Unit Parts And Major Functions Drain hose Refrigerant connecting pipe Display panel Air inlet with air filter in it Air flow louver at air outl...

Страница 6: ... in the room DO NOT place objects near the air inlet and outlet of the unit Set a timer and use the built in SLEEP ECONOMY mode if applicable If you don t plan to use the unit for a long time remove the batteries from the remote control Clean the air filter every two weeks Adjust louvers properly and avoid direct airflow Louver Angle Memory Function Optional Some models are designed with a louver ...

Страница 7: ... unit turns off and the remote control is re enabled Infrared receiver Timer indicator PRE DEF pre heating defrost indicator Operation indicator Adjusting Air Flow Direction CAUTIONS Do not try to adjust the horizontal louver by hand This may cause damage the mechanism and result in condensation forming on the air outlets Manual button Manual Swing Press Air Direction to fix the louver at a desire...

Страница 8: ...er or other solvents to clean the unit They can cause the plastic surface to crack or deform DO NOT wash the unit under running water Doing so creates an electrical hazard DO NOT use water hotter than 40 C 104 F to clean the front panel This can cause the panel to become deformed or discolored Clean the unit using a damp lint free cloth and neutral detergent Dry the unit with a dry lint free cloth...

Страница 9: ... after Extended Non Use 1 Remove any obstacles blocking the vents of both the indoor and outdoor units 2 Clean the air filter and the front grille of the indoor unit Reinstall the clean dry air filter in its original position 3 Turn on the main power switch at least 12 hours prior to operating the unit Storing the Unit While Not In Use 1 Run the appliance on FAN mode for 12 hours in a warm room to...

Страница 10: ... its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature has been reached at which point the unit turns off the compressor The unit will resume operating when the temperature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned...

Страница 11: ... indoor or outdoor unit is dirty Clean the affected heat exchanger The air filter is dirty Remove the filter and clean it according to instructions The air inlet or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat is generated by sunlight C...

Страница 12: ...lfunction 9 Off E8 9 Other twin model malfunction 10 Off E9 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error 4 On F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5 On F4 15 Outdoor fan speed DC fan motor only malfunction 6 On F5 16 T2b sensor error 7 On...

Страница 13: ...pal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will also take back the old appliance free of charge Sell the appliance to certified scrap metal dealers NOTE Disposing of this applia...

Страница 14: ... Page 14 QSBPZU 023AEN 16122600000003 20160606 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Страница 15: ... Page 15 ...

Страница 16: ... Page 16 ...

Страница 17: ... Page 17 ...

Страница 18: ... Page 18 ...

Отзывы: