This electric water heater should be installed at the place without sunshine or rain spray.
Please cut off power supply if not use for long time.
Please blow down the water for about 10 seconds to drain away the impurities in the pipe before
connecting the water source to the electric water heater to avoid blockage of water heater.
If long time no use the unit, check the water heater first before use. Electrify after the water
flows out stably.
Do not spray water to air switch or heater body directly, to avoid moist.
Please cut off the power in the weather of thunder and rain to avoid damaging the water heater.
If not use for long period of time, please cut off water inlet to prolong the lifespan of the water
heater.
Check the power cord connecting terminals frequently to make sure that they are well and
reliably contacted, no overheating phenomenon, and grounding is good or not.
Disassembly shower head and sealing ring with filter to clean periodically.
DECLARATION:
this water heater can only be maintained by authorized service personnel,
incorrect installation and using method may cause serious injury or loss of property.
●
●
●
●
●
●
●
●
5. MAINTENANCE
WARNING
Do cut off power supply before maintenance, to avoid danger like electric shock.
!
4.5 To Adjust Water Temperature
Rotate the handle of water flow adjusting valve to adjust to proper water flow. Adjust power by rotating
knob, clockwise rotate, power will be increased and water temperature increase accordingly or vice
versa.
NOTE
For first time using, ensure electrify after the unit is filled fully with water and there is
stable water flow comes out from shower head.
The electric water heater may be damaged if the water hardness is too high. To
guarantee the normal service life, please install and put it into use on condition that the
local water hardness is less than 450mg/L (CaCO3).
The water pressure is increased when Pump is started; Rotate Pump knob to adjust water pressure,
rotate clockwise, water pressure is increased and vice versa.
4.7 To Adjust Water Pressure (For MWH-38P3 & MWH-38P3-RS)
If the water flow is small and power is high while using the unit, outlet water temperature is rather
high; the unit will stop heating automatically. At this time, please lower the power and adjust the
water flow faster in order to avoid inconsistency of water temperature.
4.8 Use After Overheating Protection
9
When the unit is working under normal condition, press “PUMP”, The pump will start immediately and
has been working until the water flow insufficient 1.2L/min for more than 3 seconds.