background image

         

WARNING

 

 

Plug in power plug properly. Otherwise, it may cause electric shock or fire due to excess heat 
generation. 

 

Do not operate or stop the unit by inserting or pulling out the power plug. It may cause electric 
shock or fire due to heat generation. 

 

Do not damage or use an unspecified power cord. It may cause electric shock or fire. If the 
power cord is damaged, it must be replaced by the manufacturer or an authorized service 
centre or a similarly qualified person in order to avoid a hazard. 

 

Do not modify power cord length or share the outlet with other appliances. It may cause electric 
shock or fire due to heat generation. 

 

Do not operate with wet hands or in damp environment. It may cause electric shock. 

 

Unplug the unit or disconnect the power supply to the unit, if strange sounds, smell, or smoke 
comes from it. It may cause fire and electric shock. 

 

Do not use the socket if it is loose or damaged. It may cause fire and electric shock. 

 

Leave the door closed while the air conditioner is running. It is not designed to cool the entire 
house. 

 

Do not use the power cord close to heating appliances. It may cause fire and electric shock. 

 

Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, 
thinner, etc. It may cause an explosion or fire. 

 

Ventilate room before operating air conditioner if there is a gas leakage from another appliance. 
It may cause explosion, fire and burns. 

 

Do not disassemble or modify unit. It may cause failure and electric shock. 

 

The appliance shall be installed in accordance with national wiring regulations. 

 

If connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm 
clearances in all poles, and have a leakage current that may exceed 10mA, the residual current 
device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection 
must be incorporated in the fixed wiring in accordance with the wiring rules. 

 

This appliance can be used by children aged from 8 years and above and persons with 

reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning use of the appliance in a safe way and understand 
the hazards involved. Children shall not play the appliance. Cleaning and user maintenance 
shall not be made by children without supervision. (EN Standard requirements) 

 

This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety. (IEC Standard requirements) 

 

Children should be supervised to ensure that they do not play with the appliance. 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard. 

 

The appliance shall be installed in accordance with national wiring regulations. 

 

Do not operate this appliance in a wet room such as a bathroom or laundry room. 

 

The appliance with electric heater shall have at least 1-meter space to the combustible 
materials. 

 

Contact the authorized service technician for repair or maintenance of this unit. 

 

 

Содержание MWH-07CM3X1

Страница 1: ...AIR CONDITIONER R410A Owner s Manual Installation Manual Model MWH 07CM3X1 MWH 09CM3X1 MWH 12CM3X1 MWH 18CM3X1 MWH 24CM3U1 Before using your air conditioner please read this manual carefully and keep...

Страница 2: ...troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all ENVIRONMENT From 31 December 2018 the disposal licensing control import and expo...

Страница 3: ...ance with national wiring regulations If connecting power to fixed wiring an all pole disconnection device which has at least 3mm clearances in all poles and have a leakage current that may exceed 10m...

Страница 4: ...erate with wet hands or in damp environment Do not direct airflow at room occupants only It may cause electric shock or due to heat generation It may cause electric shock This could damage your health...

Страница 5: ...ion with windows opened may cause wetting of indoor and soaking of household furniture It may cause electric shock and damage It may cause failure of product or fire Do not place obstacles around air...

Страница 6: ...om when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Usage...

Страница 7: ...through the power cord see Fig 2 Please contact the manufacturer or its service agent or a similar qualified person if you want to replace it 3 Be sure that the unit being correctly grounded The wall...

Страница 8: ...ally start and stop the compressor in order to maintain the desired set temperature Rotate the thermostat selector clockwise for higher cool settings Higher cool settings will provide lower room tempe...

Страница 9: ...e controls featured in this manual are representative of many available models Your model may offer slightly different features The desired cool setting is selected by rotating the knob to the right t...

Страница 10: ...air alternately to obtain comfortable cooling The vertical louvers may be stopped at any position when the AUTO SWING switch is turned OFF For the units without AUTO SWING feature manually To adjust v...

Страница 11: ...pside 3 Clean the filter with warm soapy water The water should be below 40O C to prevent distortion of the filter 4 Rinse off and gently shake off excess water from the filter Allow the filter to dry...

Страница 12: ...y onto the bottom of cabinet by screws Connect an extension drain hose locally purchased to the outlet of drain tray Installation procedures of back drainage Fit the seal provided as accessory onto th...

Страница 13: ...condensed water into the room about 10mm or 1 4 bubble with level 5 Install the unit with its bottom portion 75 150cm above the floor level 6 The power cord must be connected to an independent circui...

Страница 14: ...m sealing strips on the housing remain in position 2 Connect the air conditioner to the power and position excess cord length beneath the air conditioner base 3 Engage the chassis fixing brackets into...

Страница 15: ...four kinds of removing the frame Remove the two screws on the left and right chassis fixing brackets then remove the two chassis fixing brackets as shown in Fig 3A Remove one screw on the chassis fixi...

Страница 16: ...ith the temperature sensor cable See Fig 9 2 Fix the screws on the frame See Fig 3A 3B 3C 3D Step 5 Install the air filter and front panel 1 Install the air filter into the frame s slot from upside to...

Страница 17: ...ower is restored reconnect plug in the power cord switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Air conditioner does not cool eno...

Страница 18: ...346x585 3 1 5 MWH 09CM3X1 450x346x585 3 1 5 MWH 12CM3X1 600x380x560 3 1 5 MWH 18CM3X1 660x428x680 3 2 5 MWH 24CM3U1 660x428x780 3 2 5 Minimum nominal cross sectional area of conductors Nominal cross s...

Страница 19: ...18 1 20 2 23 3 24 4 28 5 33 6 34 2018 12 31...

Страница 20: ...19 3mm 10mA RCD 30mA EN IEC...

Страница 21: ...20...

Страница 22: ...21...

Страница 23: ...22 1 2 3 4 5 6 1 2 3 1 2 3 18 43 17 32...

Страница 24: ...23 1 2 3 4 5 6 7 8 9 1 1 2 2 3 4 5 E N L 1 2 1 1 1 1 8 1 2 1 4 8 2 18000Btu h 2 4 PVC L...

Страница 25: ...24 THERMOSTAT Cooler min med max or number 1 12 1 12 SELECTOR Fan low med high Cool low med high AUTO SWING OFF ON Wait 3 minutes before Re starting 3 THERMOSTAT max min test...

Страница 26: ...25 THERMOSTAT med min med max min max SELECTOR OFF HIGH COOL MED COOL LOW COOL HIGH FAN MED FAN LOW FAN FAN MED SELECTOR LOW COOL HIGH COOL LOW COOL HIGH COOL...

Страница 27: ...26 CLOSE OPEN AUTO SWING ON AUTO SWING OFF CLOSE OPEN CLOSE OPEN...

Страница 28: ...27 1 2 3 40 C 4...

Страница 29: ...28 1 2 15 3 50 4 10 1 4 5 75 150 6 A B 5...

Страница 30: ...29 1 2 3 4 5 6 1 1 2 2 45 45 B 1 2 3A...

Страница 31: ...30 1 3A 3B 3C 3D 2 4 1 5 2 6 3 7 4 8 5 5 3B 3C 3D 4 5 6 7 10 9 8...

Страница 32: ...31 1 9 2 3A 3B 3C 3D 1 2 2 10 1 1 1C 2C 2 3C 2 600 380 560 1 5C 6C 3 1 4C 1C 4C 5C 6C 2C 3C...

Страница 33: ...32 1 2 3 90...

Страница 34: ...33 3...

Страница 35: ...m MWH 07CM3X1 450x346x585 3 1 5 MWH 09CM3X1 450x346x585 3 1 5 MWH 12CM3X1 600x380x560 3 1 5 MWH 18CM3X1 660x428x680 3 2 5 MWH 24CM3U1 660x428x780 3 2 5 mm2 A 0 75 3 and 6 1 0 6 and 10 1 5 10 and 16 2...

Страница 36: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details 16120300A22272 Version 202006...

Отзывы: