TROUBLESHOOTING   

Troubleshooting Tips   

Save time and money! Review the chart below first and you may not need to call for service. 

 

You may hear a pinging noise caused by water being picked up and thrown against the condenser on 
rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

 

 

You may hear the thermostat click when the compressor cycles on and off.

 

 

Water will collect in the base pan during high humidity or on rainy days .The water may overflow and drip 
from the outdoor side of the unit.

 

 

The fan may continue to operate when the compressor has cycled off. 

 

Problem

 

Possible Causes

 

What To Do

 

Air conditioner 

does not start

 

 

The air conditioner is 
unplugged.

 

 

Make sure the air conditioner plug is pushed 

completely into the outlet and switched on. 

 

The fuse is blown/ 
circuit

 

breaker is 

tripped.

 

 

Check the house fuse/circuit breaker box and 

replace the fuse or reset the breaker. 

 

Power failure.

 

 

If power failure occurs, switch off and 

disconnect /unplug the power cord. When power 

is restored, reconnect (plug in) the power cord, 

switch on the power and wait 3 minutes to 

restart the air conditioner to prevent tripping of 

the compressor overload. 

Air conditioner 

does  not  cool 

enough

 

 

Airflow is restricted. 

 

Make sure there are no curtains, blinds, or 

furniture blocking the front of the air conditioner. 

 

The air filter is dirty. 

 

Clean the filter at least every 2 weeks. 

 

See the operating instructions section. 

 

The room may have 

been hot. 

 

When the air conditioner is first turned on you 

need to allow time for the room to cool down. 

 

Cold air is escaping. 

 

Check for open furnace floor registers and cold 

air returns. 

 

Set the air conditioner's vent to the closed 

position. 

 

Cooling coils have iced 

up. 

 

See Air Conditioner Freezing Up below. 

Air conditioner 

freezing up

 

 

Ice blocks the air flow 

and stops the air 

conditioner from cooling 

the room. 

 

Set the fan at MED or HIGH until the ice melts. 

Noise  when  unit 

is cooling 

 

Air movement sound.   

 

Sound of fan hitting 

water-moisture removal 

system.   

 

Window vibration - poor 

installation.   

 

This is normal. If too loud, turn selector to lower 

FAN setting. 

 

This is normal when humidity is high. Close 

doors, windows and registers. 

 

Refer to installation instructions or check with 

installer. 

 

 

 

Содержание MWH-07CM3X1

Страница 1: ...AIR CONDITIONER R410A Owner s Manual Installation Manual Model MWH 07CM3X1 MWH 09CM3X1 MWH 12CM3X1 MWH 18CM3X1 MWH 24CM3U1 Before using your air conditioner please read this manual carefully and keep...

Страница 2: ...troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all ENVIRONMENT From 31 December 2018 the disposal licensing control import and expo...

Страница 3: ...ance with national wiring regulations If connecting power to fixed wiring an all pole disconnection device which has at least 3mm clearances in all poles and have a leakage current that may exceed 10m...

Страница 4: ...erate with wet hands or in damp environment Do not direct airflow at room occupants only It may cause electric shock or due to heat generation It may cause electric shock This could damage your health...

Страница 5: ...ion with windows opened may cause wetting of indoor and soaking of household furniture It may cause electric shock and damage It may cause failure of product or fire Do not place obstacles around air...

Страница 6: ...om when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Usage...

Страница 7: ...through the power cord see Fig 2 Please contact the manufacturer or its service agent or a similar qualified person if you want to replace it 3 Be sure that the unit being correctly grounded The wall...

Страница 8: ...ally start and stop the compressor in order to maintain the desired set temperature Rotate the thermostat selector clockwise for higher cool settings Higher cool settings will provide lower room tempe...

Страница 9: ...e controls featured in this manual are representative of many available models Your model may offer slightly different features The desired cool setting is selected by rotating the knob to the right t...

Страница 10: ...air alternately to obtain comfortable cooling The vertical louvers may be stopped at any position when the AUTO SWING switch is turned OFF For the units without AUTO SWING feature manually To adjust v...

Страница 11: ...pside 3 Clean the filter with warm soapy water The water should be below 40O C to prevent distortion of the filter 4 Rinse off and gently shake off excess water from the filter Allow the filter to dry...

Страница 12: ...y onto the bottom of cabinet by screws Connect an extension drain hose locally purchased to the outlet of drain tray Installation procedures of back drainage Fit the seal provided as accessory onto th...

Страница 13: ...condensed water into the room about 10mm or 1 4 bubble with level 5 Install the unit with its bottom portion 75 150cm above the floor level 6 The power cord must be connected to an independent circui...

Страница 14: ...m sealing strips on the housing remain in position 2 Connect the air conditioner to the power and position excess cord length beneath the air conditioner base 3 Engage the chassis fixing brackets into...

Страница 15: ...four kinds of removing the frame Remove the two screws on the left and right chassis fixing brackets then remove the two chassis fixing brackets as shown in Fig 3A Remove one screw on the chassis fixi...

Страница 16: ...ith the temperature sensor cable See Fig 9 2 Fix the screws on the frame See Fig 3A 3B 3C 3D Step 5 Install the air filter and front panel 1 Install the air filter into the frame s slot from upside to...

Страница 17: ...ower is restored reconnect plug in the power cord switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Air conditioner does not cool eno...

Страница 18: ...346x585 3 1 5 MWH 09CM3X1 450x346x585 3 1 5 MWH 12CM3X1 600x380x560 3 1 5 MWH 18CM3X1 660x428x680 3 2 5 MWH 24CM3U1 660x428x780 3 2 5 Minimum nominal cross sectional area of conductors Nominal cross s...

Страница 19: ...18 1 20 2 23 3 24 4 28 5 33 6 34 2018 12 31...

Страница 20: ...19 3mm 10mA RCD 30mA EN IEC...

Страница 21: ...20...

Страница 22: ...21...

Страница 23: ...22 1 2 3 4 5 6 1 2 3 1 2 3 18 43 17 32...

Страница 24: ...23 1 2 3 4 5 6 7 8 9 1 1 2 2 3 4 5 E N L 1 2 1 1 1 1 8 1 2 1 4 8 2 18000Btu h 2 4 PVC L...

Страница 25: ...24 THERMOSTAT Cooler min med max or number 1 12 1 12 SELECTOR Fan low med high Cool low med high AUTO SWING OFF ON Wait 3 minutes before Re starting 3 THERMOSTAT max min test...

Страница 26: ...25 THERMOSTAT med min med max min max SELECTOR OFF HIGH COOL MED COOL LOW COOL HIGH FAN MED FAN LOW FAN FAN MED SELECTOR LOW COOL HIGH COOL LOW COOL HIGH COOL...

Страница 27: ...26 CLOSE OPEN AUTO SWING ON AUTO SWING OFF CLOSE OPEN CLOSE OPEN...

Страница 28: ...27 1 2 3 40 C 4...

Страница 29: ...28 1 2 15 3 50 4 10 1 4 5 75 150 6 A B 5...

Страница 30: ...29 1 2 3 4 5 6 1 1 2 2 45 45 B 1 2 3A...

Страница 31: ...30 1 3A 3B 3C 3D 2 4 1 5 2 6 3 7 4 8 5 5 3B 3C 3D 4 5 6 7 10 9 8...

Страница 32: ...31 1 9 2 3A 3B 3C 3D 1 2 2 10 1 1 1C 2C 2 3C 2 600 380 560 1 5C 6C 3 1 4C 1C 4C 5C 6C 2C 3C...

Страница 33: ...32 1 2 3 90...

Страница 34: ...33 3...

Страница 35: ...m MWH 07CM3X1 450x346x585 3 1 5 MWH 09CM3X1 450x346x585 3 1 5 MWH 12CM3X1 600x380x560 3 1 5 MWH 18CM3X1 660x428x680 3 2 5 MWH 24CM3U1 660x428x780 3 2 5 mm2 A 0 75 3 and 6 1 0 6 and 10 1 5 10 and 16 2...

Страница 36: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details 16120300A22272 Version 202006...

Отзывы: