ELECTRICAL WARNINGS

Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified persons in order to avoid a hazard. 

Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire 

or electric shock. 

Do not

 pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can 

damage it, which can lead to fire or electric shock.

Do not

 modify the length of the power supply cord or use an extension cord to power the unit. 

Do not 

share the electrical outlet with other appliances. Improper or insufficient power supply can cause fire or electrical 

shock.Always install circuit breaker and a dedicated power circuit.

Do not

 use the socket if it is loose or damaged.

Do not

 place heavy object on the power cord and ensure that the cord is not compressed.

There is danger of fire or electric shock.

If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker.

Isolate supply by taking the power-plug out or disconnect the power supply to the unit, contacta qualified service 

technician. 

The product must be properly grounded at the time of installation, or electrical shock may occur.

For all electrical work, follow all local and national wiring standards, regulations, and the Electrical Connection Diagram 

located on the top panel of the unit. 

If connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm clearances in all poles, 

and have a leakage current that may exceed 10mA, the residual current device(RCD) having a rated residual operating 

current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring 

rules.

This unit is earthed through the power cord, make sure that the unit is correctly grounded. The wall outlet(Air-break 

switch) should be provided with reliable earth wire.

The unit should be provided with an individual circuit and the circuit breaker/fuse rating should be the same as that 

of the power cord and wall outlet. Power cord conductors are distinguished  according to the color as shown in Wiring 

Diagram located on the top of the machine.  

 WARNINGS FOR PRODUCT INSTALLATION

 

1. Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, 

    electrical shock, or fire.

2. Installation must be performed according to the installation instructions. Improper installation can cause water leakage, 

    electrical shock, or fire. (In North America,installation must be performed in accordance with the requirement of NEC  

    and CEC by authorized personnel only.)

3. Contact an authorized service technician for repair or maintenance of this unit. This appliance shall be installed in acc-

    ordance with national wiring regulations.

4. Only use the included accessories, parts, and specified parts for installation. Using non-standard parts can cause water 

    leakage, electrical shock, fire, and can cause the unit to fail. 

5. Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot support the unit’s 

    weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.

6. Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to your 

    home and property. 

7. For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any combustible materials.

8. 

Do not

 install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates aro-

    und the unit, it may cause fire.

9. 

Do not 

turn on the power until all work has been completed.

10. When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinsta-

      llation of the unit.

11. How to install the appliance to its support, please read the information for details in "Installation instructions" section.                

 

 

 

 

   

   

TAKE NOTE OF FUSE SPECIFICATIONS

Wall outlet

Air-break switch

The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent 

protection. The specifications of the fuse are printed on the circuit board ,such as 

T3.15A/250V(or 350V), etc, 


Содержание MWF09HB4

Страница 1: ...ation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Please check the applicable mode...

Страница 2: ...ispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take...

Страница 3: ...or a prolonged period of time If the air conditioner is used together with burners or other heating devices thoroughly ventilate the room to avoid oxygen deficiency Safety Precautions Do not allow chi...

Страница 4: ...ircuit breaker fuse rating should be the same as that of the power cord and wall outlet Power cord conductors are distinguished according to the color as shown in Wiring Diagram located on the top of...

Страница 5: ...opical models Cooling operation Heating operation Outdoor Temperature Outdoor Temperature Indoor Temperature Indoor Temperature To further optimize the performance of your unit do the following Keep d...

Страница 6: ...ressed the temperature decreases as follows 1 Celsius Scale Minimum Setting 17 16 TIMER on some models When the unit is on press the Timer button will initiate the Auto stop program the TIMER OFF indi...

Страница 7: ...louver and move to the desired position see Fig D For some units the connecting rod of the louver is provided with a convex block it can be moved between the three grooves on the left side of frame a...

Страница 8: ...ter as dust dirt particles can contribute to equipment failure Model A If your filter has a small air freshening filter optional it can be installed at any of the four positions install it at the post...

Страница 9: ...educe the cooling and heating efficiency of the air conditioner 4 Install the unit a little obliquely downward to outside not to leak the condensed water into the room about 5 7mm 5 Install the unit w...

Страница 10: ...6 Model D 1 Remove one screw securing the chassis fixing bracket then take down the chassis fixing bracket see Fig 5D 2 Remove four screws located on both sides and the back of the cabinet as shown in...

Страница 11: ...gher number and then immediately turning back to a colder number Wait approximately 3 minutes Listen for compressor to start Air from unit does not feel cold enough Air conditioner cooling but room is...

Страница 12: ...deepth of the panel may be slightly different So the dimension of D is for reference only 5000 6000 445x320x415 450x346x535 450x346x535 450x346x585 450x346x585 560x400x640 600x380x560 660x428x680 660...

Страница 13: ...CS465 R031D E AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION Thank you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner...

Страница 14: ...nt the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer Handling the remote controller 2 2...

Страница 15: ......

Страница 16: ...range of 16 C 31 C in 1 C increments 4 Press the FAN button to select the fan speed in three steps Low Med or High Press the ON OFF button to start the air conditioner 2 Fan In the Fan mode you are no...

Страница 17: ...depending on models NOTE To set Auto start time the unit must be in the Off position To set Auto stop time the unit must be in the On postion To set the Auto start time 1 Push the TIMER button when th...

Отзывы: