MIV V4+ Indoor Units 

 

DM16-01.01.02-09en 

 

Floor Standing Type MVF-A-VA1 MVB-A-VA1 

1. Feature 

1.1 

Exposed & Concealed type 

 

 

 

Air intake from front (F4 series) 

Air intake from below (F5 series) 

 

1.2 

Lower noise 

Flat shape air outlet, three speeds adjustment. Smoother airflow with less turbulence. 
Adoption of the built-in Fujikoki brand electronical expansion valve, ensures precise flow control, as well as 
lower modulation noise when EXV operating. 

1.3 

Easy Installation 

Floor standing types can be hung on the wall or installed on the floor. The former can make cleaning and 
maintenance  much  more  easily.  Running  the  piping  from  the  back  allows  the  unit  to  be  hung  on  walls. 
Cleaning under the unit, where dust tends to accumulate, is considerably easier. 

1.4 

Easy maintenance 

Filter  is  equipped  as  standard  accessory;  and  it  can  be  removed  and  cleaned  easily  due  to  Midea’s 
sophisticated design as well as the removable blades. 
Streamlined appearance makes it much more harmonious with the decoration. All metal parts are made of 
commercial grade galvanized steel, providing maximum protection against corrosion. 

1.5 

Auto restart 

When the indoor unit is powered off, it will auto restart when powered on again after 3 minutes and operate in 
the original state. 

 

 

Содержание MVB22A-VA1

Страница 1: ...02 09en Service manual MIV V4 Indoor units Floor Standing MVF22A VA1 MVF28A VA1 MVF36A VA1 MVF45A VA1 MVF56A VA1 MVF71A VA1 MVF80A VA1 MVB22A VA1 MVB28A VA1 MVB36A VA1 MVB45A VA1 MVB56A VA1 MVB71A VA1...

Страница 2: ...ts Floor Standing Type MVF A VA1 MVB A VA1 1 Floor Standing 1 Feature 2 2 Specifications 3 3 Dimensions 6 4 Service Spaces 8 5 Piping Diagrams 9 6 Wiring Diagrams 10 7 Capacity Tables 11 8 Electrical...

Страница 3: ...he floor The former can make cleaning and maintenance much more easily Running the piping from the back allows the unit to be hung on walls Cleaning under the unit where dust tends to accumulate is co...

Страница 4: ...ndoor external static pressure H Pa 12 12 12 Indoor noise level Hi Mid Lo F4 dB A 36 33 29 36 33 29 37 34 30 F5 36 33 29 36 33 29 37 34 30 Indoor unit Dimension W H D F4 mm 1000 569 225 1000 569 225 1...

Страница 5: ...pressure H Pa 12 12 Indoor noise level H M L F4 dB A 37 34 30 41 35 31 F5 37 34 30 41 35 31 Indoor unit Dimension W H D F4 mm 1200 596 225 1500 596 225 F5 1200 677 220 1500 677 220 Packing W H D F4 mm...

Страница 6: ...rnal static pressure H Pa 12 12 Indoor noise level H M L F4 dB A 44 39 33 44 39 33 F5 44 39 33 44 39 33 Indoor unit Dimension W H D F4 mm 1500 596 225 1500 596 225 F5 1500 677 220 1500 677 220 Packing...

Страница 7: ...ront Mountinghole 4 Liquidside connector Gasside connector EXV Airoutletgrille Left Cover Right Cover Airinletgrille A B C D E F G H I 4 11 4 18 138 149 5 149 5 J Unit mm MODEL MVF A VA1 A B C D E F G...

Страница 8: ...hole 4 Air inlet grille Liquid side connector Gas side connector EXV Air outlet grille Left Cover Right Cover A B C D E F G H I J 149 5 149 5 4 11 4 18 Unit mm MODEL MVB A VA1 A B C D E F G H I J 22 1...

Страница 9: ...floor F5 series Vertical unit with casing with air intake from below and air outlet on top for installation on a wall or on feet on the floor Required clearance for above 2 versions Additionally it is...

Страница 10: ...DM16 01 01 02 09en MIV V4 Indoor Units Floor Standing Type MVF A VA1 MVB A VA1 9 5 Piping Diagrams flare nut flare nut T2B gas side motor heat exchanger fan EXV liquid side T2 T1...

Страница 11: ...MIV V4 Indoor Units DM16 01 01 02 09en 10 Floor Standing Type MVF A VA1 MVB A VA1 6 Wiring Diagrams...

Страница 12: ...1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 21 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 23 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 25 0 1 9 1 6 2 3 1 8 2 6...

Страница 13: ...6 3 0 5 3 3 3 5 6 3 4 5 9 3 5 6 2 3 4 6 2 3 2 35 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 9 3 5 6 0 3 3 6 0 3 1 37 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 9 3 5 5 9 3 2 6 0 3 1 39 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6...

Страница 14: ...5 8 9 5 2 8 8 4 8 33 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 4 5 5 8 8 5 2 8 8 4 8 35 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 4 5 5 8 6 5 1 8 6 4 8 37 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 3 5 4 8 4 5 0 8 6 4...

Страница 15: ...2 14 2 14 2 14 2 14 2 14 11 00 10 50 2 24 2 24 2 24 2 24 2 24 2 24 10 00 9 50 2 34 2 34 2 34 2 34 2 34 2 34 9 10 8 50 2 40 2 40 2 40 2 40 2 40 2 40 7 60 7 00 2 43 2 43 2 43 2 43 2 43 2 43 5 60 5 00 2...

Страница 16: ...20 3 00 5 92 5 92 5 92 5 92 5 80 5 29 4 10 5 00 6 11 6 11 6 11 6 11 5 80 5 29 6 00 7 00 6 30 6 30 6 30 6 11 5 80 5 29 7 90 9 00 6 49 6 49 6 30 6 11 5 80 5 29 9 80 11 00 6 68 6 68 6 30 6 11 5 80 5 29...

Страница 17: ...70 0 00 8 01 8 01 8 01 8 01 8 01 7 56 2 20 3 00 8 46 8 46 8 46 8 46 8 28 7 56 4 10 5 00 8 73 8 73 8 73 8 73 8 28 7 56 6 00 7 00 9 00 9 00 9 00 8 73 8 28 7 56 7 90 9 00 9 27 9 27 9 00 8 73 8 28 7 56 9...

Страница 18: ...0 220 240V 198 254 0 3 5 0 049 0 24 MVB36A VA1 50 220 240V 198 254 0 3 5 0 049 0 24 MVF45A VA1 50 220 240V 198 254 0 4 5 0 06 0 3 MVB45A VA1 50 220 240V 198 254 0 4 5 0 06 0 3 MVF56A VA1 50 220 240V 1...

Страница 19: ...i anechoic chamber conversion value measured at a point 1m in front of the unit at a height of 1 5m 9 2 Test value Model Sound test value dB A H M L MVF22A VA1 36 33 29 MVB22A VA1 36 33 29 MVF28A VA1...

Страница 20: ...sure level dB 0dB 0 0002 bar Audibility limits of continuous white sound Octave band center frequency Hz Sound pressure level dB 0dB 0 0002 bar A udibility lim its of continuous white sound O ctave ba...

Отзывы: