background image

 

 

Contents 

 

50Hz  R410A  ON/OFF  SERIES 

Service Manual 2017 

 

 

 

 

Содержание MUE-48CRN1-RB4

Страница 1: ...Contents i 50Hz R410A ON OFF SERIES Service Manual 2017 ...

Страница 2: ......

Страница 3: ...nformation 1 Part 2 Indoor Units 8 Part 3 Outdoor Units 167 Part 4 Installation 189 Part 5 Electrical Control System 231 The specifications designs and information in this book are subject to change without notice for product improvement ...

Страница 4: ......

Страница 5: ...General Information General Information 1 Part 1 General Information 1 Model Lists 2 2 External Appearance 5 2 1 Indoor Units 5 2 2 Outdoor Units 6 3 Nomenclature 7 ...

Страница 6: ... Floor standing Cooling only Cooling and heating J2 Floor standing Cooling and heating S2 Floor standing Cooling only S4 Floor standing Cooling and heating Cooling only E2 Floor standing Cooling and heating 1 2 Outdoor Units Universal Outdoor unit Model Compressor type Compressor Brand Matched indoor units Heat Pump MOBA30U 12HN1 Q ROTARY GMCC MCA3 12HRN1 Q MUE 12HRN1 Q MTB 12HWN1 Q MOBA30U 18HN1 ...

Страница 7: ...0U 24CN1 QB9 ROTARY GMCC MCD 24CRN1 QB9 MFS2 24CRN1 QB7 MFS4 24CRN1 QB8 MOCA31U 24CN1 QB9 ROTARY GMCC MFS4 24CRN1 QB9 MOCA30U 24CN1 Q ROTARY GMCC MTB 24CWN1 Q MUE 24CRN1 Q MCD 24CRN1 Q MFGA 24CRN1 Q MFM 24CRN1 Q MTI 24CWN1 Q MOD30U 30CN1 Q ROTARY Shanghai Hitachi MCD 30CRN1 QB4 MTB 30CWN1 QB4 MUE 30CRN1 QB4 MTI 30CWN1 Q MOD30U 36CN1 Q ROTARY Shanghai Hitachi MUE 36CRN1 QB4 MCD 36CRN1 QB4 MTB 36CWN...

Страница 8: ...Model Lists 4 General Information MUE 60CRN1 R MTB 60CWN1 R MTI 60CWN1 R ...

Страница 9: ...Indoor Units Compact Four way cassette A5 Middle static pressure duct pressure duct standing standing External Appearance way cassette A5 Middle static pressure duct Super A6 Middle static pressure duct Ceiling floor type M Floor E2 Floor Super slim 4 way Cassette A6 Middle static pressure duct Ceiling floor type M Floor standing E2 Floor standing way Cassette A6 Middle static pressure duct Ceilin...

Страница 10: ...oor Units External Appearance standing 2 2 Outdoor Units Single fan outdoor unit Single fan outdoor unit Single fan outdoor unit S4 Floor S4 Floor standing Double fan outdoor unit standing Double fan outdoor unit General Information Double fan outdoor unit General Information General Information ...

Страница 11: ...ed Time A Time A Designed B Time B Designed C Time C Designed D Time D Designed Product Category C Cassette Type V AHU Type T Duct Type F Console Type U Ceiling Floor Type H High Static Pressure Duct Type Midea 3 2 Outdoor Unit M O T4 D30 U 36 H D N1 R RC4 Energy Efficiency Code Power Supply Q 220 240V 1N 50HZ R 380 420V 3N 50Hz N 220 230V 1N 60Hz D 220V 3N 60Hz C 380 420v 3N 60HZ Refrigerant N1 R...

Страница 12: ... 9 Super slim Cassette Type 19 A5 Duct Type 37 A6 Duct Type 57 High Static Pressure Duct Type 77 Ceiling Floor Type 94 GA Floor standing Type 110 M Floor standing Type 119 J2 Floor standing Type 129 S2 Floor standing Type 138 S4 Floor standing Type 147 E2 Floor standing Type 158 ...

Страница 13: ...ure Distributions Reference Data Wiring Diagrams Electric Characteristics Sound Levels The Specification of Power Field Wiring elocity and Temperature Distributions Reference Data Electric Characteristics The Specification of Power Four way Cassette elocity and Temperature Distributions Reference Data way Cassette elocity and Temperature Distributions Reference Data way Cassette Type Compact eloci...

Страница 14: ...ing air outlet design affords comfortable feeling it s just smaller than the ceiling board so it s very easy for installation and will not damage the decoration The panel size is 647 50 647mm The hooks are designed in the four corners of the body which can save installation space box is simply and safely built inside the indoor unit It s convenient for installation and maintenance Can check the co...

Страница 15: ...Four 2 Four way Cassette Type Compact Dimensions 2 way Cassette Type Compact Dimensions way Cassette Type Compact Dimensions Dimensions 11 ...

Страница 16: ...Service Space 12 3 Service Space 12 Service Space 3 Service Space Service Space Four way Cassette Type way Cassette Type way Cassette Type Compact Compact ...

Страница 17: ...ce Data Air Velocity and Temperature Distributions Reference Data Air Velocity and T Air Velocity and Temperature Distributions Reference Data Air Velocity and T Air Velocity and Temperature Distributions Reference Data Air Velocity and Temperature Distributions Reference Data Air Velocity and Temperature Distributions Reference Data emperature Distributions Reference Data Air Velocity and Tempera...

Страница 18: ...rams 14 Wiring Diagrams 5 MCA3 12HRN1 MCA3 12CRN1 Wiring Diagrams Wiring Diagrams 12HRN1 Q MCA3 12CRN1 QB6 MCA3 Wiring Diagrams Q MCA3 18HRN1 Q MCA3 18CRN1 Q 18CRN1 QB5 Four way Cassette Type way Cassette Type way Cassette Type Compact Compact ...

Страница 19: ...ote MFA Max Fuse Amps A Model 12CRN1 QB6 12HRN1 Q 18CRN1 QB5 18HRN1 Q Electric Characteristics Hz 12CRN1 QB6 50 12HRN1 Q 50 18CRN1 QB5 50 18HRN1 Q 50 MFA Max Fuse Amps A QB6 QB5 Indoor Units Voltage 220 240V 220 240V 220 240V 220 240V 1 4m Microphone H 40 42 46 48 Indoor Units Min 198V 198V 198V 198V 1 4m Microphone Noise level dB A M 36 38 39 41 Power Supply Max MFA 254V 16 254V 16 254V 16 254V 1...

Страница 20: ...ntroller 9 Remote controller holder 10 Mounting screw ST2 9 10 11 Alkaline dry batteries AM4 12 Owner s manual 13 Installation manual 1 Expansible hook 2 Installation hook Installation paper board let pipe sheath let pipe clasp 6 Tightening band 7 Drain joint 8 Remote controller 9 Remote controller holder 10 Mounting screw ST2 9 10 11 Alkaline dry batteries AM4 12 Owner s manual 13 Installation ma...

Страница 21: ...er Wiring Strong Weak Electric Signal The Specification of Power Phase Frequency and Voltage Circuit Breaker Fuse A Indoor Unit Power Wiring mm 2 Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal Frequency and Voltage Outdoor Unit Power Wiring Electric Signal Weak Electric Signal MCA3 12CRN1 MCA3 18CRN1 1 phase 220 240V 50Hz 20 16 3 2 5 2 5 3 2 5 2 0 75 2 0 5 12CR...

Страница 22: ...Indoor Units 18 10 Indoor Units 18 Field Wiring 10 Field Wiring Field Wiring Four way Cassette Type way Cassette Type way Cassette Type Compact Compact ...

Страница 23: ... slim Cassette Type 19 Super slim Cassette Type 1 Features 20 2 Dimensions 23 3 Service Space 24 4 Wiring Diagrams 25 5 Electric Characteristics 30 6 Sound Levels 31 7 Accessories 32 8 The Specification of Power 33 9 Field Wiring 34 ...

Страница 24: ...comfort air blowing is possible Auto lifting panel design more convenient to clean and maintain the filter optional 1 2 Fresh air intake function Fresh air fulfills air quality more healthy and comfortable Ventilation motor is optional to increase the effect of fresh air 1 3Optional ionizer generator Ionizer generator is optional to get refreshing air to your room New air intake ...

Страница 25: ...tor Ionizer can be switched on or off by remote controller When pressing the Clean Air button on the remote controller Ionizer will work and the Reserve external air duct more flexible for the air supply Due to the improvement of structure more convenient to repair or replace the draining pump Ventilation motor connector Ionizer can be switched on or off by remote controller When pressing the Clea...

Страница 26: ...als for the connection of alarm lamp and Alarm lamp in draining pump to make sure condensed water drain out reliably Terminals for alarm lamp and long distance on Reserve terminals for the connection of alarm lamp and Long in draining pump to make sure condensed water drain out reliably distance on off controller connection are Reserve terminals for the connection of alarm lamp and long distance o...

Страница 27: ...port 680 780 780 680 136 126 91 196 132 A A B A A B A A B A B Service hole for draining pump Fresh air intake 75 55 80 80 4 install hanger Gas side Liquid side E parts box 135 90 Panel Body 92 92 92 92 D D 92 92 D D D D 92 92 92 92 92 92 92 92 D D Unit mm Model A B C D 18 24 160 75 205 50 30 48 160 95 245 60 60 160 95 287 60 ...

Страница 28: ...Service Space 24 Super slim Cassette Type 3 Service Space 1000mm 1000mm 1000mm 1000m m ...

Страница 29: ...Wiring Diagrams Super slim Cassette Type 25 4 Wiring Diagrams MCD 18HRN1 Q MCD 24HRN1 Q MCD 36HRN1 Q ...

Страница 30: ...Indoor Units 26 Super slim Cassette Type MCD 36HRN1 R ...

Страница 31: ...Wiring Diagrams Super slim Cassette Type 27 MCD 48HRN1 R MCD 60HRN1 R ...

Страница 32: ...Indoor Units 28 Super slim Cassette Type MCD 18CRN1 Q MCD 18CRN1 QC0 MCD 24CRN1 Q MCD 24CRN1 QB9 MCD 30CRN1 QB4 MCD 36CRN1 QB4 MCD 36CRN1 QB6 ...

Страница 33: ...Wiring Diagrams Super slim Cassette Type 29 MCD 36CRN1 RB4 MCD 48CRN1 RB4 MCD 60CRN1 R MCD 48CRN1 RB4 ...

Страница 34: ...R 50 380 415V 342V 436V 25 MCD 60HRN1 R 50 380 415V 342V 436V 25 MCD 18CRN1 Q 50 220 240V 198V 254V 20 MCD 18CRN1 QC0 50 220 240V 198V 254V 20 MCD 24CRN1 QB9 50 220 240V 198V 254V 25 MCD 24CRN1 Q 50 220 240V 198V 254V 25 MCD 30CRN1 QB4 50 220 240V 198V 254V 40 MCD 36CRN1 QB4 50 220 240V 198V 254V 40 MCD 36CRN1 QB6 50 220 240V 198V 254V MCD 36CRN1 RB4 50 380 415V 342V 436V 20 MCD 48CRN1 RB4 50 380 ...

Страница 35: ...2 48 45 MCD 36HRN1 R 52 48 45 MCD 48HRN1 R 53 48 44 MCD 60HRN1 R 53 48 44 MCD 24CRN1 QB9 51 48 44 MCD 18CRN1 Q 42 49 37 MCD 18CRN1 QC0 40 37 33 MCD 24CRN1 Q 48 43 38 MCD 30CRN1 QB4 54 50 46 MCD 36CRN1 QB4 54 50 47 MCD 36CRN1 RB4 53 50 47 MCD 36CRN1 QB6 52 49 45 MCD 48CRN1 RB4 22022511000996 53 51 50 MCD 48CRN1 RB4 22022511001076 54 52 50 MCD 60CRN1 R 55 53 51 ...

Страница 36: ... Out let pipe sheath 1 Out let pipe clasp 1 Remote controller Its Frame Remote controller Its Frame 1 Remote controller holder 1 Mounting screw ST2 9 10 C H 2 Remote controller manual 1 Alkaline dry batteries AM4 2 Others Owner s manual 1 Installation manual 1 Network wires 1 Installation accessory The product you have might not be provided the following accessories Expansible hook 4 Installation ...

Страница 37: ...f Power Phase Frequency and Voltage Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal 1 Frequency and Ground Wiring Outdoor Unit Power Strong Electric Weak Electric Signal 2 0 75 Phase Frequency and Voltage Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal Frequency and Voltage Ground Wiring Outdoor Unit Power Strong Electric Sign...

Страница 38: ...Indoor Units 34 Super slim Cassette Type 9 Field Wiring MCD 18HRN1 Q MCD 18CRN1 Q MCD 18CRN1 QC0 MCD 24CRN1 QB9 MCD 36CRN1 QB4 ...

Страница 39: ...Field Wiring Super slim Cassette Type 35 MCD 24HRN1 Q MCD 24CRN1 Q MCD 30CRN1 QB4 MCD 36HRN1 Q MCD 36CRN1 QB6 ...

Страница 40: ...Indoor Units 36 Super slim Cassette Type MCD 36HRN1 R MCD 36CRN1 RB4 MCD 48CRN1 RB4 MCD 60CRN1 R MCD 48HRN1 R MCD 60HRN1 R ...

Страница 41: ...pe 37 A5 Duct Type 1 Features 38 2 Dimensions 41 3 Service Space 42 4 Wiring Diagrams 43 5 Static Pressure 47 6 Electric Characteristics 50 7 Sound Levels 51 8 Accessories 52 9 The Specification of Power 53 10 Field Wiring 54 ...

Страница 42: ... in rear side or Replace the motor or centrifugal fan Remove the ventilated panel firstly Remove a half of blower housing and centrifugal fan Directly remove two bolts and then replace the motor or centrifugal fan easily Air intake from rear Standard Front Board Canvas Air Passage Filter Panel for easy installation Easy Installation Two air inlet styles Bottom side or Rear side Air inlet from rear...

Страница 43: ... central control ports off ports and central control ports can connect the cable of an on off control function or group control function in drain pump can lift the water to 750mm upmost It s convenient to install drainage piping under off ports Central control ports off and central control ports off ports and central control ports can connect the cable of an on off control function or group contro...

Страница 44: ...de when the chips Wired Controller Standard The standard indoor unit can be controlled by wired controller There is a display board with a receiver in the E box Move out the display and fix it in other place even m The unit will realized remoter control er and the display board can display the error code or production code when the chips Remote Controller Optional The standard indoor unit can be c...

Страница 45: ...uct without filter Unit mm Model Btu h Outline dimension mm Air outlet opening size Air return opening size Size of install hanger Size of refrigerant pipe A B C D E F G H I J K L M H1 H2 W1 W2 9K 12K 700 210 635 570 65 493 35 119 595 200 80 740 350 120 143 95 150 18K 920 210 635 570 65 713 35 119 815 200 80 960 350 120 143 95 150 24K 920 270 635 570 65 713 35 179 815 260 20 960 350 120 143 95 150...

Страница 46: ...Service Space 42 Duct Type 3 Service Space Ensure enough space required for installation and maintenance ...

Страница 47: ...Wiring Diagrams A5 Duct Type 43 4 Wiring Diagrams MTB 12HWN1 Q MTB 18HWN1 Q MTB 24HWN1 Q ...

Страница 48: ...Wiring Diagrams 44 Duct Type MTB 09CWN1 Q MTB 12CWN1 QB6 MTB 18CWN1 QB5 MTB 24CWN1 Q MTB 30CWN1 QB4 MTB 36CWN1 QB4 ...

Страница 49: ...Wiring Diagrams A5 Duct Type 45 MTB 36CWN1 QB6 MTB 36CWN1 RB4 MTB 48CWN1 R MTB 60CWN1 R ...

Страница 50: ...Wiring Diagrams 46 Duct Type MTB 48HWN1 R MTB 60HWN1 R ...

Страница 51: ...0 55 60 Air flow rate m3 h External static pressure Pa 9K 12K 0 200 400 600 800 1000 1200 0 5 10 15 20 25 30 35 40 45 50 55 60 Air flow rate m3 h External static pressure Pa 18K 0 200 400 600 800 1000 1200 1400 1600 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Air flow rate m3 h External static pressure Pa 24K ...

Страница 52: ...80 Air flow rate m3 h External static pressure Pa 30K 0 500 1000 1500 2000 2500 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Air flow rate m3 h External static pressure Pa 36K 0 500 1000 1500 2000 2500 3000 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Air flow rate m3 h External static pressure Pa 48K ...

Страница 53: ...Static Pressure A5 Duct Type 49 0 500 1000 1500 2000 2500 3000 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Air flow rate m3 h External static pressure Pa 60K ...

Страница 54: ...2V 436V 25 MTB 60HWN1 R 50 380 415V 342V 436V 25 MTB 09CWN1 Q 50 220 240V 198V 254V 20 MTB 12CWN1 QB6 50 220 240V 198V 254V 20 MTB 18CWN1 QB5 50 220 240V 198V 254V 20 MTB 24CWN1 Q 50 220 240V 198V 254V 25 MTB 30CWN1 QB4 50 220 240V 198V 254V 40 MTB 36CWN1 QB4 50 220 240V 198V 254V 40 MTB 36CWN1 QB6 50 220 240V 198V 254V MTB 36CWN1 RB4 50 380 415V 342V 436V 20 MTB 48CWN1 R 50 380 415V 342V 436V 25 ...

Страница 55: ...TB 12HWN1 Q 40 36 32 MTB 18HWN1 Q 43 37 36 MTB 24HWN1 Q 45 40 38 MTB 48HWN1 R 50 45 40 MTB 60HWN1 R 47 40 38 MTB 09CWN1 Q 39 34 32 MTB 12CWN1 QB6 38 34 32 MTB 18CWN1 QB5 40 34 33 MTB 24CWN1 Q 43 34 31 MTB 30CWN1 QB4 49 40 38 MTB 36CWN1 QB4 51 43 40 MTB 36CWN1 QB6 50 41 40 MTB 36CWN1 RB4 51 45 43 MTB 48CWN1 R 50 44 42 MTB 60CWN1 R 52 46 44 ...

Страница 56: ...cessories Name Shape Quantity Tubing Fittings Soundproof insulation sheath 2 Binding tape 1 Seal sponge 1 Drainpipe Fittings Drain joint 1 Seal ring 1 Wire controller Wire controller 1 others Owner s manual 1 Installation manual 1 ...

Страница 57: ...or Connecting Wiring mm 2 Phase Frequency and Voltage Indoor Unit Power Wiring mm 2 Indoor Outdoor Connecting Wiring Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal The Specification of Power 9 1 phase Frequency and 25 20 3 1 5 Ground Wiring 1 5 Outdoor Unit 3 1 5 Strong Electric Weak Electric Phase Frequency and Voltage Ground Wiring Outdoor Unit Power Wiring S...

Страница 58: ...Field Wiring 54 Duct Type 10 Field Wiring MTB 09CWN1 Q MTB 12CWN1 QB6 MTB 18CWN1 QB5 ...

Страница 59: ...Field Wiring A5 Duct Type 55 MTB 12HWN1 Q MTB 18HWN1 Q MTB 24HWN1 Q MTB 24CWN1 Q MTB 30CWN1 QB4 MTB 36CWN1 QB4 ...

Страница 60: ...Field Wiring 56 Duct Type MTB 36CWN1 QB6 MTB 36CWN1 RB4 MTB 48CWN1 R MTB 60CWN1 R MTB 48HWN1 R MTB 60HWN1 R ...

Страница 61: ...pe 57 A6 Duct Type 1 Features 58 2 Dimensions 61 3 Service Space 62 4 Wiring Diagrams 63 5 Static Pressure 68 6 Electric Characteristics 70 7 Sound Levels 71 8 Accessories 72 9 The Specification of Power 73 10 Field Wiring 74 ...

Страница 62: ...nit 1 2 Installation accessories Optional Front Board Canvas Air Passage Filter Panel for easy installation Air Intake Way Bottom side or Rear side The frame size of air inlet in rear and bottom is the same It s very easy to switch to match different Standard The industry Lowest height is designed to be fitted into tight roof spaces 36K unit 300mm Front Board Canvas Air Passage Filter Panel for ea...

Страница 63: ...side or bottom side With a larger window design once the motor and the blower wheels have been detached heat exchanger and water receiver tray in behind can be seen very clearly Dust can be easily removed from the inside by vacuum 1 5 Easy maintenance A6 duct allows operators maintenance the motor from the bottom more easily compare with that on the top A6 duct has big space for maintenance at the...

Страница 64: ...in pump Optional in drain pump can lift the water to 750mm upmost in drain pump can lift the water to 750mm upmost in drain pump can lift the water to 750mm upmost in drain pump can lift the water to 750mm upmost which widens the drainage piping range which widens the drainage piping range which widens the drainage piping range Max 750mm Duct Type which widens the drainage piping range Duct Type ...

Страница 65: ...size Air return opening size Size of install hanger Size of refrigerant pipe A B C D E F G H I J K L M H1 H2 W1 W2 18K 880 210 674 600 140 706 50 136 782 190 40 920 508 78 148 88 112 24K 36K 1100 249 774 700 140 926 50 175 1001 228 5 1140 598 80 150 130 155 48K 60K 1200 300 874 800 123 1044 50 227 1101 280 5 1240 697 80 150 185 210 ...

Страница 66: ...tion and maintenance The ceiling is horizontal and its structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The connecting pipe and drainpipe could be extracted out easily There is no direct radiation from heater ...

Страница 67: ...Wiring Diagrams A6 Duct Type 63 4 Wiring Diagrams MTI 18HWN1 Q MTI 24HWN1 Q ...

Страница 68: ...Wiring Diagrams 64 Duct Type MTI 30HWN1 Q MTI 36HWN1 Q MTI 36HWN1 R ...

Страница 69: ...Wiring Diagrams A6 Duct Type 65 MTI 60HWN1 R MTI 18CWN1 Q ...

Страница 70: ...Wiring Diagrams 66 Duct Type MTI 24CWN1 Q MTI 30CWN1 Q ...

Страница 71: ...Wiring Diagrams A6 Duct Type 67 MTI 36CWN1 R MTI 60CWN1 R MTI 48CWN1 R ...

Страница 72: ...8K 24K MTI 30CWN1 Q 0 200 400 600 800 1000 1200 0 10 20 30 40 50 60 70 80 90 100 Air flow rate m h External Static Pressure Pa 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 20 40 60 80 100 120 140 160 Air flow rate m h External Static Pressure Pa ...

Страница 73: ... 36K 48K 60K 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 20 40 60 80 100 120 140 160 Air flow rate m h External Static Pressure Pa 0 500 1000 1500 2000 2500 3000 3500 0 20 40 60 80 100 120 140 160 Air flow rate m h External Static Pressure Pa ...

Страница 74: ...V 254V 25 MTI 30HWN1 Q 50 220 240V 198V 254V MTI 36HWN1 Q 50 220 240V 198V 254V MTI 36HWN1 R 50 220 240V 198V 254V MTI 60HWN1 R 50 220 240V 198V 254V MTI 18CWN1 Q 50 220 240V 198V 254V 20 MTI 24CWN1 Q 50 220 240V 198V 254V MTI 30CWN1 Q 50 220 240V 198V 254V MTI 36CWN1 R 50 220 240V 198V 254V MTI 48CWN1 R 50 220 240V 198V 254V MTI 60CWN1 R 50 220 240V 198V 254V Note MFA Max Fuse Amps A ...

Страница 75: ...uct Duct Model Noise level dB A H M L MTI 18HWN1 Q 44 42 40 MTI 24HWN1 Q 44 41 38 MTI 30HWN1 Q 50 44 40 MTI 36HWN1 Q 49 43 39 MTI 36HWN1 R 49 43 40 MTI 60HWN1 R 58 53 49 MTI 18CWN1 Q 46 42 40 MTI 24CWN1 Q 42 39 37 MTI 30CWN1 Q 49 43 38 MTI 36CWN1 R 46 41 37 MTI 48CWN1 R 54 51 49 MTI 60CWN1 R 56 52 48 ...

Страница 76: ...e Shape Quantity Tubing Fittings Soundproof insulation sheath 2 Binding tape 1 Seal sponge 1 Drainpipe Fittings for cooling heating units Drain joint 1 Seal ring 1 Wire controller Wire controller 1 others Owner s manual 1 Installation manual 1 ...

Страница 77: ...e Indoor Unit Power Wiring mm 2 Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal 18 1 phase Frequency 25 20 Unit Power Wiring 3 2 5 Ground 2 5 Outdoor 3 2 5 Electric 2 1 0 Electric 2 0 75 2 0 5 The Specification of Power 18 1 phase Frequency and 25 20 3 2 5 2 5 Outdoor Unit 3 2 5 Strong Electric Weak Electric 18 24 phase 1 phase 220 240V 50Hz 25 20 32 25 3 2 5 3 ...

Страница 78: ...Field Wiring 74 Duct Type 10 Field Wiring MTI 18HWN1 Q MTI 24HWN1 Q ...

Страница 79: ...Field Wiring A6 Duct Type 75 MTI 30HWN1 Q MTI 36HWN1 Q MTI 24CWN1 Q MTI 30CWN1 Q MTI 36HWN1 R MTI 36CWN1 R MTI 48CWN1 R MTI 60HWN1 R ...

Страница 80: ...Field Wiring 76 Duct Type MTI 18CWN1 Q MTI 48HWN1 R MTI 60CWN1 R ...

Страница 81: ...pe 77 High Static Pressure Duct Type 1 Features 78 2 Dimensions 80 3 Service Space 81 4 Wiring Diagrams 82 5 Static Pressure 87 6 Electric Characteristics 88 7 Sound Levels 89 8 Accessories 90 9 The Specification of Power 91 10 Field Wiring 92 ...

Страница 82: ...pecially recommended for spacious and large rooms like large stores and factories The unit can be opened from top or bottom The air outlet flange is isolated from either top panel or base panel which makes the maintenance much easier when connecting duct Different solutions for any shape room by using kinds of air distribution ducts The filter can be easily removed or installed from the rear side ...

Страница 83: ...Features High Static Pressure Duct Type 79 ...

Страница 84: ...n Size of mounted lug Air outlet opening size Air inlet opening size A B C D E F G H I J K L M N O 24 525 900 270 397 936 844 185 160 780 120 851 226 215 665 110 36 525 1110 270 397 1146 1054 185 220 960 120 1061 226 315 875 110 48 60 625 1200 380 495 1236 1000 253 270 900 170 1145 334 325 925 130 ...

Страница 85: ...rvice Space High Static Pressure Duct Type 81 3 Service Space Ensure enough space required for installation and maintenance 500mm or more 600mm or more Indoor unit 600mmx600mm Maintenance and repair space ...

Страница 86: ...Wiring Diagrams 82 High Static Pressure Duct Type 4 Wiring Diagrams MHG 24HWN1 Q ...

Страница 87: ...Wiring Diagrams High Static Pressure Duct Type 83 MHG 36HWN1 R MHG 36HWN1 Q ...

Страница 88: ...Wiring Diagrams 84 High Static Pressure Duct Type ...

Страница 89: ...Wiring Diagrams High Static Pressure Duct Type 85 MHG 48HWN1 R ...

Страница 90: ...Wiring Diagrams 86 High Static Pressure Duct Type MHG 60HWN1 R ...

Страница 91: ...20 Air flow rate m3 h External static pressure Pa 24K 0 500 1000 1500 2000 2500 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Air flow rate m3 h External static pressure Pa 36K 0 500 1000 1500 2000 2500 3000 3500 4000 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Air flow rate m3 h External static pressure Pa 48 60K ...

Страница 92: ...acteristics Model Indoor Unit Power Supply Hz Voltage Min Max MFA MHG 24HWN1 Q 50 220 240V 198V 254V 25 MHG 36HWN1 R 50 220 240V 198V 254V MHG 36HWN1 Q 50 220 240V 198V 254V MHG 48HWN1 R 50 380 415V 342V 436V 25 MHG 60HWN1 R 50 380 415V 342V 436V 25 Notes MFA Max Fuse Amps A ...

Страница 93: ...re Duct Type 89 7 Sound Levels Suction Discharge Microphone 1 5m Concealed Duct Type Duct Duct Model Noise level dB A H M L MHG 24HWN1 Q 48 42 38 MHG 36HWN1 R 55 52 50 MHG 36HWN1 Q 54 51 49 MHG 48HWN1 R 51 49 46 MHG 60HWN1 R 52 50 48 ...

Страница 94: ...er Its Frame Wired controller Owner Wired controller Owner Installation manual Soundproof insulation sheath Drain joint Seal ring Wired controller Owner s manual of Wired controller Owner s manual Installation manual Name Soundproof insulation sheath Wired controller s manual of wired controller Wired controller installation manual s manual Installation manual Soundproof insulation sheath wired co...

Страница 95: ...door Unit Power Wiring mm2 Indoor Outdoor Connecting Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal The Specification of Power Frequency and Voltage Ground Wiring Outdoor Unit Power Strong Electric Signal Weak Electric Signal 24 1 phase Frequency and Voltage 220 240V 50Hz 32 25 3 2 5 2 5 Outdoor Unit Power 3 2 5 3 1 0 2 0 2 36 1 phase 240V 50Hz 50 40 4 0 3 4 0 ...

Страница 96: ...Field Wiring 92 High Static Pressure Duct Type 10 Field Wiring MHG 24HWN1 Q MHG 36HWN1 R ...

Страница 97: ...Field Wiring High Static Pressure Duct Type 93 MHG 36HWN1 Q MHG 48HWN1 R MHG 60HWN1 R ...

Страница 98: ...eiling Floor Type Ceiling Floor Type 1 Features 95 2 Dimensions 96 3 Service Space 97 4 Wiring Diagram 98 5 Electric Characteristics 103 6 Sound Levels 104 7 Accessories 105 8 The Specification of Power 106 9 Field Wiring 107 ...

Страница 99: ...ng 1 3 Two direction auto swing vertical horizontal and wide angle air flow Air flow directional control minimizes the air resistance and produces wilder air flow to vertical direction The range of horizontal air discharge is widened which secures wider air flow distribution to provide more comfortable air circulation no matter where the unit is set up 1 4 Three level fan speed more humanism desig...

Страница 100: ...sions A B 220 222 C 120 2 40 120 140 2 33 Wiring connection port 204 94 Fresh air intake Drain discharge port Refrigerant pipe hole Hanging arm D Capacity Btu h A B C D 12 24K 1068 675 235 983 30 36K 1285 675 235 1200 48 60K 1650 675 235 1565 ...

Страница 101: ...Service Space Ceiling Floor Type 97 3 Service Space ...

Страница 102: ...Wiring Diagram 98 Ceiling Floor Type 4 Wiring Diagram MUE 12HRN1 Q MUE 18HRN1 Q MUE 24HRN1 Q MUE 30HRN1 Q ...

Страница 103: ...Wiring Diagram Ceiling Floor Type 99 MUE 36HRN1 R MUE 36HRN1 Q ...

Страница 104: ...Wiring Diagram 100 Ceiling Floor Type MUE 48HRN1 R MUE 60HRN1 R MUE 18CRN1 QB5 ...

Страница 105: ...Wiring Diagram Ceiling Floor Type 101 MUE 24CRN1 Q MUE 30CRN1 QB4 MUE 36CRN1 QB4 MUE 36CRN1 QB6 ...

Страница 106: ...Wiring Diagram 102 Ceiling Floor Type MUE 36CRN1 RB4 MUE 48CRN1 RB4 MUE 60CRN1 R ...

Страница 107: ...E 36HRN1 Q 50 220 240V 198V 242V MUE 36HRN1 R 50 220 240V 198V 242V MUE 48HRN1 R 50 380 415V 342V 436V 25 MUE 60HRN1 R 50 380 415V 342V 436V 25 MUE 18CRN1 QB5 50 220 240V 198V 242V 20 MUE 24CRN1 Q 50 220 240V 198V 242V 25 MUE 30CRN1 QB4 50 220 240V 198V 242V 40 MUE 36CRN1 QB4 50 220 240V 198V 242V 40 MUE 36CRN1 QB6 50 220 240V 198V 242V MUE 36CRN1 RB4 50 380 415V 342V 436V 20 MUE 48CRN1 RB4 50 380...

Страница 108: ...N1 Q 37 33 30 MUE 18HRN1 Q 53 48 43 MUE 24HRN1 Q 54 48 44 MUE 30HRN1 Q 54 49 45 MUE 36HRN1 Q 54 49 46 MUE 36HRN1 R 54 50 47 MUE 48HRN1 R 53 48 44 MUE 60HRN1 R 55 49 46 MUE 18CRN1 QB5 52 48 44 MUE 24CRN1 Q 52 47 44 MUE 30CRN1 QB4 53 49 46 MUE 36CRN1 QB4 55 52 48 MUE 36CRN1 QB6 54 50 46 MUE 36CRN1 RB4 54 50 46 MUE 48CRN1 RB4 57 53 50 MUE 60CRN1 R 58 55 52 ...

Страница 109: ...unting screw ST2 9 10 4 Alkaline dry batteries AM4 5 Owner s manual 6 Installation manual 7 Remote controller manual Remote controller 2 Remote controller holder 3 Mounting screw ST2 9 10 4 Alkaline dry batteries AM4 5 Owner s manual 6 Installation manual 7 Remote controller manual 2 Remote controller holder 3 Mounting screw ST2 9 10 C H 4 Alkaline dry batteries AM4 7 Remote controller manual Acce...

Страница 110: ...ignal Weak Electric Signal Indoor Unit Power Wiring mm 2 Indoor Outdoor Connecting Wiring mm2 Phase Frequency and Voltage Indoor Unit Power Wiring mm2 Ground Wiring Outdoor Unit Power Wiring Strong Electric Signal Weak Electric Signal The Specification of Power 1 Frequency and Ground Wiring Outdoor Unit Power Strong Electric Weak Electric Signal 2 0 75 1 Frequency and Ground Wiring Outdoor Unit Po...

Страница 111: ...Field Wiring Ceiling Floor Type 107 9 Field Wiring MUE 18CRN1 QB5 MUE 12HRN1 Q MUE 18HRN1 Q ...

Страница 112: ...Field Wiring 108 Ceiling Floor Type MUE 24HRN1 Q MUE 24CRN1 Q MUE 30CRN1 QB4 MUE 36CRN1 QB4 MUE 36HRN1 R ...

Страница 113: ...Field Wiring Ceiling Floor Type 109 MUE 30HRN1 Q MUE 36HRN1 Q MUE 36CRN1 QB6 MUE 36CRN1 RB4 MUE 48CRN1 RB4 MUE 60CRN1 R MUE 48HRN1 R MUE 60HRN1 R ...

Страница 114: ...teristics Sound Levels Accessories The Specification of Power Features Dimensions Service Space Wiring Diagrams Electric Characteristics Sound Levels Accessories The Specification of Power GA Wiring Diagrams Electric Characteristics The Specification of Power Floor The Specification of Power Floor standing Type GA Floor standing Type GA Floor standing Type standing Type 111 112 113 114 116 116 117...

Страница 115: ...sed automatically to prevent the dust Big LCD display easy to read and to operate Optional GA1 GA2 panel healthy filter and auto Adopts simple and bright style panel GA series are suitable for most different space and show in good When press OFF to turn off the unit the air outlet louver can be closed automatically to prevent the dust Big LCD display easy to read and to operate Optional GA1 GA2 pa...

Страница 116: ... Dimensions 112 Dimensions 2 Model Dimensions Dimension Model 18 24 48 60 Dimension 24 48 60 Dimension W mm 510 550 610 W mm 10 550 610 D mm 240 350 390 GA Floor H mm 1695 1800 1925 GA Floor standing type standing type ...

Страница 117: ...GA Floor 3 GA Floor standing type Service Space 3 standing type Service Space Service Space Service Space 113 Service Space 113 ...

Страница 118: ...ing Diagrams 114 4 MFGA MFGA Wiring Diagrams 114 Wiring Diagrams 4 MFGA 24ARN1 MFGA 18CRN1 Wiring Diagrams Wiring Diagrams 24ARN1 Q 18CRN1 QB6 Wiring Diagrams GA Floor GA Floor standing type standing type ...

Страница 119: ...GA Floor standing type 115 MFGA 24CRN1 Q MFGA 48CRN1 RB4 MFGA 60CRN1 R ...

Страница 120: ...FGA 24ARN1 MFGA 24CRN1 MFGA 48CRN1 MFGA 60CRN1 Electric Characteristics Hz QB6 50 Q 50 Q 50 RB4 50 R 50 MFA Max Fuse Amps A Model 18CRN1 QB6 24ARN1 Q 24CRN1 Q 48CRN1 RB4 60CRN1 R Indoor Units Voltage 220 240V 220 240V 380 415V 380 415V 380 415V 1m Noise level dB A H 48 52 52 56 52 Indoor Units Min 240V 198V 240V 198V 415V 342V 415V 342V 415V 342V 1m Microphone Noise level dB A Power Supply Max MFA...

Страница 121: ...ction Ring Remote Battery Remote Controller Remote controller manual User s manual Installation manual Remote controller holder Optional parts Ratproof board on some models Band on some models Drain Hose on some models Connection Cables on some models Putty on some models Part Name tapping Screw 3 9 25 Sleeve Cover Sound Heat Insulation Sleeves protection Ring Remote Controller Remote controller m...

Страница 122: ...upply 220 240V 50Hz 220 240V 50Hz 380 415V 50Hz NOTE The cable size and the current of the fuse or switch are determined by the maximum current the nameplate which located on the side panel of the unit Please refer to the Power supply Input Rated Amp Switch Fuse A 50Hz 50Hz 50Hz NOTE The cable size and the current of the fuse or switch are determined by the maximum current the nameplate which loca...

Страница 123: ... M Floor standing Type 119 M Floor standing Type 1 Features 120 2 Dimensions 121 3 Service Space 122 4 Wiring Diagrams 123 5 Electric Characteristics 125 6 Sound Levels 126 7 Accessories 127 8 The Specification of Power 128 ...

Страница 124: ...ght touch buttons make the operation easy clear and precise 1 4 Comfortable Air Flow Long distance air supply 3D air distribution Vertical and horizontal louvers auto swing optional 1 5 Fresh Air Optional A fresh air inlet can be customized on the return air channel When the indoor fan runs the fresh air will be sucked inside through the fresh air pipe which makes the air more clear and healthy 1 ...

Страница 125: ...Dimensions M Floor standing Type 121 11 Dimensions Dimension Model W mm D mm H mm 24 500 315 1700 48 550 418 1824 60 600 455 1934 H W D ...

Страница 126: ...Service Space 122 M Floor standing Type 12 Service Space ...

Страница 127: ...Wiring Diagrams M Floor standing Type 123 13 Wiring Diagrams MFM 24ARN1 Q MFM 24CRN1 Q ...

Страница 128: ...Wiring Diagrams 124 M Floor standing Type MFM 48CRN1 RB4 MFM 60CRN1 R ...

Страница 129: ...ectric Characteristics Model Indoor Units Power Supply Hz Voltage Min Max MFA MFM 24ARN1 Q 50 220 240V 198V 254V 25 MFM 24CRN1 Q 50 220 240V 198V 254V 25 MFM 48CRN1 RB4 50 380 415V 342V 436V 25 MFM 60CRN1 R 50 380 415V 342V 436V 25 Notes MFA Max Fuse Amps A ...

Страница 130: ...Sound Levels 126 M Floor standing Type 15 Sound Levels 1m 1m Microphone Model Noise level dB A H L MFM 24ARN1 Q 49 43 MFM 24CRN1 Q 49 44 MFM 48CRN1 RB4 53 49 MFM 60CRN1 R 54 50 ...

Страница 131: ...hole protection Ring Remote Battery Remote Controller Remote controller manual User s manual Installation manual Remote controller holder Optional parts Ratproof board on some models Band on some models Drain Hose on some models Connection Cables on some models Putty on some models Part Name tapping Screw 3 9 25 Sleeve Cover Sound Heat Insulation Sleeves protection Ring Remote Controller Remote co...

Страница 132: ...ize 24000Btu h 220 240V 50Hz 32 25 2 5 mm 3 3 mm for with PTC 48000 60000Btu h 380 415V 50Hz 32 25 2 5 mm NOTE The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse and switch ...

Страница 133: ...J2 Floor standing Type 129 J2 Floor standing Type 1 Features 130 2 Dimensions 131 3 Service Space 132 4 Wiring Diagrams 133 5 Electric Characteristics 134 6 Sound Levels 135 7 Accessories 136 8 The Specification of Power 137 ...

Страница 134: ...losed automatically to prevent the dust falling in 1 3 New Control Panel Big bright VLED display with touch switch makes a easy and clearly control 1 4 New Packaging The improved indoor unit packaging is designed to endure harsh logistics conditions to keep the unit intact to customers 1 5 Comfortable Air Flow Long distance air supply 3D air distribution Vertical and horizontal louvers auto swing ...

Страница 135: ...Dimensions J2 Floor standing Type 131 2 Dimensions Dimension Mode W mm D mm H mm 24 500 290 1700 48 540 410 1825 ...

Страница 136: ...Service Space 132 J2 Floor standing Type 3 Service Space ...

Страница 137: ...The Specification of Power J2 Floor standing Type 133 4 Wiring Diagrams MFJ 24ARN1 Q MFJ 48ARN1 R ...

Страница 138: ...ristics 134 J2 Floor standing Type 5 Electric Characteristics Model Indoor Units Power Supply Hz Voltage Min Max MFA MFJ 24ARN1 Q 50 220 240V 198V 242V 25 MFJ 48ARN1 R 50 380 415V 342V 436V 25 Notes MFA Max Fuse Amps A ...

Страница 139: ...The Specification of Power J2 Floor standing Type 135 6 Sound Levels 1m 1m Microphone Model Noise level dB A H L MFJ 24ARN1 Q 49 44 MFJ 48ARN1 R 54 50 ...

Страница 140: ...ing Remote Battery Remote Controller Remote controller User s manual Installation manual Remote controller holder Optional parts Ratproof board on some models Band on some models Drain Hose on some models Connection Cables on some models Putty on some models Part Name tapping Screw 3 9 25 Sleeve Cover Sound Heat Insulation Sleeves protection Ring Remote Controller Remote controller manual Installa...

Страница 141: ...tu h 220 240V 50Hz 32 25 2 5 mm 3 3 mm for with PTC 48000 60000Btu h 380 415V 50Hz 32 25 2 5 mm 4 0 mm for with PTC NOTE The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse and switch ...

Страница 142: ...138 S2 Floor standing Type S2 Floor standing Type 1 Features 139 2 Dimensions 140 3 Service Space 141 4 Wiring Diagrams 142 5 Electric Characteristics 143 6 Sound Levels 144 7 Accessories 145 8 The Specification of Power 146 ...

Страница 143: ...distance air supply 3D air distribution Vertical and horizontal louvers auto swing 1 5 Double Air Filters Optional Various healthy filters are optional Adopts simple and bright style panel S2 series are suitable for most different space and show in good information very clearly the operation easy clear and precise 3D air distribution Vertical and horizontal louvers auto swing Various healthy filte...

Страница 144: ...Dimensions 140 S2 Floor standing Type 2 Dimensions Dimension Mode W mm D mm H mm 24 500 230 1680 48 540 379 1775 ...

Страница 145: ...Service Space S2 Floor standing Type 141 3 Service Space ...

Страница 146: ...Wiring Diagrams 142 S2 Floor standing Type 4 Wiring Diagrams MFS2 24CRN1 QB7 MFS2 48CRN1 RB4 ...

Страница 147: ...Power S2 Floor standing Type 143 5 Electric Characteristics Model Indoor Units Power Supply Hz Voltage Min Max MFA MFS2 24CRN1 QB7 50 220 240V 198V 254V 25 MFS2 48CRN1 RB4 50 380 415V 342V 254V 25 Notes MFA Max Fuse Amps A ...

Страница 148: ...Sound Levels 144 S2 Floor standing Type 6 Sound Levels 1m 1m Microphone Model Noise level dB A H L MFS2 24CRN1 QB7 48 44 MFS2 48CRN1 RB4 56 54 ...

Страница 149: ...ote Battery Remote Controller Remote controller manual User s manual Installation manual Remote controller holder Optional parts Ratproof board on some models Band on some models Drain Hose on some models Connection Cables on some Putty on some models Part Name tapping Screw 3 9 25 Sleeve Cover Sound Heat Insulation Sleeves protection Ring Remote Controller controller manual Installation manual Re...

Страница 150: ...d Size 24000Btu h 220 240V 50Hz 32 25 2 5 mm 3 3 mm for with PTC 48000Btu h 380 415V 50Hz 32 25 2 5 mm NOTE The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse and switch ...

Страница 151: ...S4 Floor standing Type 147 S4 Floor standing Type 1 Features 148 2 Dimensions 149 3 Service Space 150 4 Wiring Diagrams 151 5 Electric Characteristics 154 6 Sound Levels 155 7 Accessories 156 8 The Specification of Power 157 ...

Страница 152: ... Control Panel Big bright LED display with big buttons makes a easy and clearly control 1 3 Dust proof Air Outlet When press OFF to turn off the unit the air outlet louver can be closed automatically to prevent the dust falling in 1 5 New Packaging The improved indoor unit packaging is designed to endure harsh logistics conditions to keep the unit intact to customers ...

Страница 153: ...Dimensions S4 Floor standing Type 149 2 Dimensions Dimension Mode W mm D mm H mm 24 500 255 1660 48 540 370 1780 ...

Страница 154: ...Service Space 150 S4 Floor standing Type 3 Service Space ...

Страница 155: ...Wiring Diagrams S4 Floor standing Type 151 4 Wiring Diagrams MFS4 24ARN1 Q MFS4 48ARN1 R MFS4 24CRN1 QB8 ...

Страница 156: ...Wiring Diagrams 152 S4 Floor standing Type MFS4 24CRN1 QB9 ...

Страница 157: ...Wiring Diagrams S4 Floor standing Type 153 MFS4 48CRN1 RB8 ...

Страница 158: ...Model Indoor Units Power Supply Hz Voltage Min Max MFA MFS4 24ARN1 Q 50 220 240V 198V 254V 25 MFS4 48ARN1 R 50 380 415V 342V 436V 25 MFS4 24CRN1 QB8 50 220 240V 198V 254V 25 MFS4 24CRN1 QB9 50 220 240V 198V 254V 25 MFS4 48CRN1 RB8 50 380 415V 342V 436V 25 Notes MFA Max Fuse Amps A ...

Страница 159: ...ound Levels S4 Floor standing Type 155 6 Sound Levels 1m 1m Microphone Model Noise level dB A H L MFS4 24ARN1 Q 52 47 MFS4 48ARN1 R 58 54 MFS4 24CRN1 QB8 54 49 MFS4 24CRN1 QB9 52 45 MFS4 48CRN1 RB8 56 53 ...

Страница 160: ...ote Battery Remote Controller Remote controller manual User s manual Installation manual Remote controller holder Optional parts Ratproof board on some models Band on some models Drain Hose on some models Connection Cables on some models Putty on some models Part Name tapping Screw 3 9 25 Sleeve Cover Sound Heat Insulation Sleeves Remote Controller Remote controller manual Installation manual Remo...

Страница 161: ...00Btu h 220 240V 50Hz 32 25 2 5 mm 3 3 mm for with PTC 48000Btu h 380 415V 50Hz 32 25 2 5 mm 4 0 mm for with PTC NOTE The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse and switch ...

Страница 162: ...158 E2 Floor standing Type E2 Floor standing Type 1 Features 159 2 Dimensions 160 3 Service Space 161 4 Wiring Diagrams 162 5 Electric Characteristics 163 6 Sound Levels 164 7 Accessories 165 8 The Specification of Power 166 ...

Страница 163: ...e suitable for using in big Big bright LED display with touch switch makes a easy and clearly control The LED in the air outlet of E series floor standing unit displays two colors Red color indicates warm airflow in heating mode while green light in dictates cooling air in cooling mode indoor unit packaging is designed to endure harsh logistics conditions to keep the unit Heat Cool Big air volume ...

Страница 164: ...Dimensions 160 E2 Floor standing Type 2 Dimensions Dimension Mode W mm D mm H mm 60 605 385 1895 ...

Страница 165: ...Service Space E2 Floor standing Type 161 3 Service Space ...

Страница 166: ...Wiring Diagrams 162 E2 Floor standing Type 4 Wiring Diagrams MFE 60ARN1 R ...

Страница 167: ...Electric Characteristics E2 Floor standing Type 163 5 Electric Characteristics Model Indoor Units Power Supply Hz Voltage Min Max MFA MFE 60ARN1 R 50 380 415V 342V 436V Note MFA Max Fuse Amps A ...

Страница 168: ...Sound Levels 164 E2 Floor standing Type 6 Sound Levels 1m 1m Microphone Model Noise level dB A H L MFE 60ARN1 R 59 54 ...

Страница 169: ...e protection Ring Remote Battery Remote Controller Remote controller User s manual Installation manual Remote controller holder Optional parts Ratproof board on some models Band on some models Drain Hose on some models Connection Cables on some models Putty on some models Part Name tapping Screw 3 9 25 Sleeve Cover Sound Heat Insulation Sleeves protection Ring Remote Controller Remote controller m...

Страница 170: ...ch Fuse A Power Cord Size 60000Btu h 380 415V 50Hz 32 25 2 5 mm 4 0 mm for with PTC NOTE The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse and switch ...

Страница 171: ...tdoor Units Outdoor Units 167 Part 3 Outdoor Units 1 Dimensions 168 2 Service Space 171 3 Piping Diagrams 172 4 Wiring Diagrams 177 5 Electric Characteristics 186 6 Operation Limits 187 7 Sound Levels 188 ...

Страница 172: ...N1 Q 770 300 555 840 487 298 MOCA30U 24HN1 Q 845 363 702 914 540 350 MOCA30U 24CN1 QB9 845 363 702 914 540 350 MOCA30U 24CN1 Q 845 363 702 914 540 350 MOD30U 30CN1 Q 946 410 810 1030 673 403 MOD30U 30HN1 Q 946 410 810 1030 673 403 MOD30U 36CN1 Q 946 410 810 1030 673 403 MOD30U 36CN1 R 946 410 810 1030 673 403 MOD32U 36CN1 QB6 946 410 810 1030 673 403 MOD32U 36CN1 RB6 946 410 810 1030 673 403 MOD31...

Страница 173: ...mensions Outdoor Units 169 Model Unit mm W D H W1 A B MODU 48CN1 R 900 350 1170 985 590 378 MOU 48HN1 R 900 350 1170 985 590 378 MODU 60CN1 R 900 350 1170 985 590 378 MOUA 60HN1 R 900 350 1170 985 590 378 ...

Страница 174: ...Dimensions 170 Outdoor Units Model Unit mm W D H W1 A B MOE30U 60HN1 R 952 415 1333 1045 634 404 ...

Страница 175: ...Service Space Outdoor Units 171 12 Service Space More than 60cm More than 30cm More than 60cm More than 200cm Air inlet Air inlet More than 30cm Air outlet Wall or obstacle Maintain channel ...

Страница 176: ...NGE CONDENSER COMPRESSOR CAPILIARY TUBE T2 Evaporator temp sensor T1 Room temp sensor MOBA30U 12HN1 Q MOBA30U 18HN1 Q LIQUID SIDE GAS SIDE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR 2 WAY VALVE 3 WAY VALVE 4 WAY VALVE COOLING HEATING T2 Evaporator temp sensor T1 Room temp sensor T3 Condenser temp sensor ACCUMULATOR INDOOR OUTDOOR CHECK VALVE Heating Model only CAPILIARY TUBE ...

Страница 177: ... temp sensor T3 Condenser temp sensor ACCUMULATOR INDOOR OUTDOOR MOD31U 36HN1 Q MOD31U 36HN1 R MOU 48HN1 R 22023016000194 MOE30U 60HN1 R Throttle orifice LIQUID SIDE GAS SIDE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER Compressor 2 WAY VALVE 3 WAY VALVE 4 WAY VALVE COOLING HEATING T2 Evaporator temp sensor T1 Room temp sensor Accumulator T5 Discharge temp sensor High pressure switch Low press...

Страница 178: ...Room temp sensor T3 Condenser temp sensor T5 Discharge temp sensor High pressure switch T4 Ambient temp sensor Low pressure switch INDOOR OUTDOOR CHECK VALVE Heating Model only CAPILLARY TUBE MOCA30U 24CN1 QB9 MOCA30U 24CN1 Q MOD30U 30CN1 Q MOD30U 36CN1 Q MOCA31U 24CN1 QB9 MOD32U 36CN1 RB6 INDOOR OUTDOOR LIQUID SIDE GAS SIDE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR T2 Evaporator...

Страница 179: ...XCHANGE CONDENSER COMPRESSOR T2 Evaporator temp sensor T1 Room temp sensor High pressure switch Throttle orifice MOD32U 36CN1 QB6 INDOOR OUTDOOR LIQUID SIDE GAS SIDE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR T2 Evaporator temp sensor T1 Room temp sensor High pressure switch Throttle orifice T5 Discharge temp sensor ...

Страница 180: ...OOR LIQUID SIDE GAS SIDE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR T2 Evaporator temp sensor T1 Roomtemp sensor Throttle orifice T3 Condenser temp sensor T5 Discharge temp sensor High pressure switch Low pressure switch ACCUMULATOR T4 Ambient temp sensor ...

Страница 181: ...Wiring Diagrams Outdoor Units 177 14 Wiring Diagrams MOBA30U 12HN1 Q MOBA30U 18HN1 Q MOCA30U 24HN1 Q ...

Страница 182: ...Wiring Diagrams 178 Outdoor Units MOD30U 30HN1 Q MOD31U 36HN1 Q ...

Страница 183: ...Wiring Diagrams Outdoor Units 179 MOD31U 36HN1 R MOU 48HN1 R ...

Страница 184: ...Wiring Diagrams 180 Outdoor Units MOE30U 60HN1 R MOUA 60HN1 R ...

Страница 185: ...Wiring Diagrams Outdoor Units 181 MOAB30U 09CN1 Q MOBA30U 12CN1 QB6 MOBA30U 18CN1 Q MOCA30U 24CN1 Q MOCA30U 18CN1 QC0 ...

Страница 186: ...Wiring Diagrams 182 Outdoor Units MOCA30U 24CN1 QB9 MOCA31U 24CN1 QB9 MOD30U 30CN1 Q MOD30U 36CN1 Q ...

Страница 187: ...Wiring Diagrams Outdoor Units 183 MOD30U 36CN1 R ...

Страница 188: ...Wiring Diagrams 184 Outdoor Units MOD32U 36CN1 QB6 MOD32U 36CN1 RB6 MOD30U 48CN1 RB4 ...

Страница 189: ...Wiring Diagrams Outdoor Units 185 MODU 48CN1 R MODU 60CN1 R ...

Страница 190: ...54V MOCA30U 24CN1 QB9 50 220 240V 198V 254V MOCA30U 24CN1 Q 50 220 240V 198V 254V MOD30U 30CN1 Q 50 220 240V 198V 254V MOD30U 30HN1 Q 50 220 240V 198V 254V MOD31U 36HN1 Q 50 220 240V 198V 254V 40 MOD30U 36CN1 Q 50 220 240V 198V 254V MOD30U 36CN1 R 50 380 415V 342V 436V MOD32U 36CN1 RB6 50 380 415V 342V 436V MOD32U 36CN1 QB6 50 220 240V 198V 254V 40 MOD31U 36HN1 R 50 380 415V 342V 436V 20 MOD30U 48...

Страница 191: ...tdoor temperature 18 43 7 24 7 43 For the models with low temperature cooling system 10 15 25 30 35 20 15 20 25 30 35 40 45 Indoor temperature WB Outdoor temperature DB STD Cooling 43 17 32 10 5 0 5 10 18 7 With Low Ambient Cooling System 10 15 25 30 20 15 20 25 Indoor temperature WB Outdoor temperature DB Heating 10 5 0 5 10 24 7 0 5 STD ...

Страница 192: ... 56 MOBA30U 18CN1 Q 62 MOCA30U 18CN1 QC0 58 MOCA31U 24CN1 QB9 61 MOBA30U 18HN1 Q 62 MOCA30U 24HN1 Q 62 MOCA30U 24CN1 QB9 61 MOCA30U 24CN1 Q 61 MOD30U 30CN1 Q 61 MOD30U 30HN1 Q 64 MOD31U 36HN1 Q 63 MOD30U 36CN1 Q 66 MOD32U 36CN1 RB6 63 MOD32U 36CN1 QB6 62 MOD30U 36CN1 R 66 MOD31U 36HN1 R 64 MOD30U 48CN1 RB4 68 MODU 48CN1 R 62 MOU 48HN1 R 63 MODU 60CN1 R 65 MOE30U 60HN1 R 62 MOUA 60HN1 R 63 ...

Страница 193: ... unit installation 192 4 Outdoor unit installation Side Discharge Unit 221 5 Refrigerant pipe installation 222 6 Drainage pipe installation 223 7 Vacuum Drying and Leakage Checking 227 8 Additional refrigerant charge 228 9 Engineering of insulation 228 10 Engineering of electrical wiring 229 11 Test operation 230 ...

Страница 194: ... Wiring connection and electric safety checking Test operation Refrigerant pipe installation and insulation Drainage pipe installation and insulation Indoor unit installation location selection Outdoor unit installation location selection Indoor unit installation Outdoor unit installation Refrigerant pipe installation and insulation Drainage pipe installation and insulation ...

Страница 195: ...on The place shall easily support the outdoor unit s weight Locate the outdoor unit as close to indoor unit as possible The piping length and height drop can not exceed the allowable value The place where the noise vibration and outlet air do not disturb the neighbors There is enough room for installation and maintenance The air outlet and the air inlet are not impeded and not face the strong wind...

Страница 196: ...ion 3 1 1 Service space for indoor unit 3 1 2 Bolt pitch 3 1 3 Install the pendant bolt Select the position of installation hooks according to the hook holes positions showed in upper picture Drill four holes of Ø12mm 45 50mm deep at the selected positions on the ceiling Then embed the expansible hooks fittings ...

Страница 197: ... In general L is half of the screw length of the Locate the air conditioner firmly by wrenching the nuts after having adjust Face the concave side of the installation hooks toward the expansible hooks Determine the length of the then cut off the unnecessary part If the ceiling is extremely high please determine the length of the installation hook depending on the real Make the 4 suspender through ...

Страница 198: ...e screws under the panel hooks till the panel closely stick on the ceiling to avoid condensate Hang the panel to the hooks on the mainbody Tighten the screws under the panel hooks till the panel closely stick on the ceiling to avoid condensate Tighten the screws under the panel hooks till the panel closely stick on the ceiling to avoid condensate Tighten the screws under the panel hooks till the p...

Страница 199: ...l box with corresponding terminators on the body respectively Note The panel shall be installed after the wiring connected 3 2 Super slim cassette indoor unit installation 3 2 1 Service space for indoor unit Model A H Remark 18 24 205 235 Cooling Cooling Heating 30 48 245 275 Cooling Cooling Heating 60 287 317 Cooling Cooling Heating 3 2 2 Bolt pitch ...

Страница 200: ...ides of ceiling are even The body s lower part should sink into the ceiling for 10 12 mm In general L is half of the screw length of t Select the position of installation hooks according to the hook holes positions showed in upper picture Drill four holes of Ø12mm 45 50mm deep at the selected positions on the ceiling Then embed the Make the 4 suspender through the 4 hanger of the main body to susp...

Страница 201: ... grille DO NOT make the ropes enwinded or blocked Locate the air conditioner firmly by wrenching the nuts after having adjusted the body s position well he mainbody If the panel is with auto the grille DO NOT make the ropes enwinded or blocked Locate the air conditioner firmly by wrenching the nuts after having adjusted the body s position well he mainbody If the panel is with auto the grille DO N...

Страница 202: ...Indoor unit installation 198 Installation Tighten the screws under the panel hooks till the panel closely stick on the ceiling to avoid condensate water ...

Страница 203: ...d terminator of the swing motor and that of the control box with corresponding terminators on the body respectively Install the 4 corner covers back Note The panel shall be installed after the wiring connected 3 3 A5 duct indoor unit installation 3 3 1 Service space for indoor unit 3 3 2 Bolt pitch ...

Страница 204: ...2mm 45 50mm deep at the selected positions on the ceiling Then embed the Make the 4 suspender through the 4 hanger of the main body to suspend it Adjust the hexangular nuts on the four installation hooks evenly to ensure the balance of the body Use a leveling the levelness of the main body is within 1 Size of outline dimension mounted plug M 350 350 350 490 500 Select the position of installation ...

Страница 205: ...6 Install the air duct Please design the air duct as below recommended picture 3 3 7 Change the air inlet direction Take off ventilation panel and flange cut off the staples at side rail Stick the attached seal sponge as per the indicating place in the following fig and then change the mounting positions of air return panel and air return flange ...

Страница 206: ...ase plug it into flange inclined from air return opening and then push up The installation has finish upon filter mesh which fixing blocks have been insert to the flange positional holes 3 4 A6 duct indoor unit installation 3 4 1 Service space for indoor unit 3 4 2 Bolt pitch ...

Страница 207: ...e installation of hanging screw bolts Cut off the roof beam Strengthen the place that has been cut off and consolidate the roof beam 4 After the selection of installation location position the refrigerant pipes drain pipes indoor outdoor wires to the connection places before hanging up the machine 5 Drill 4 holes 10cm 4 deep at the ceiling hook positions in the internal ceiling Be sure to hold the...

Страница 208: ...tion foam should be wrapped outside the duct to avoid condensate and internal duct underlayer shall be added to reduce the noise for special requirement 7 Adjust the air inlet direction From rear side to under Take off ventilation panel and flange Change the mounting positions of ventilation panel and air return flange Confirm the minimum drain tilt is 1 100 or more ccessories installation 1 Insta...

Страница 209: ...n install the filter mesh please plug it into flange as shown in figure below NOTE All the figures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased The actual unit shall prevail ...

Страница 210: ...4 397 936 36 397 1146 48 60 495 1236 3 3 Install the pendant bolt Select the position of installation hooks according to the hook holes positions showed in upper picture Drill four holes of Ø12mm 45 50mm deep at the selected positions on the ceiling Then embed the expansible hooks fittings 500mm or more 600mm or more Indoor unit 600mmx600mm Maintenance and repair space ...

Страница 211: ...tallation hooks evenly to ensure the balance of the body Use a leveling instrument to make sure the levelness of the main body is within 1 Please design the air duct as below recommended picture nder through the 4 hanger of the main body to suspend it Adjust the hexangular nuts on the four installation hooks evenly to ensure the balance of the body Use a leveling instrument to make sure Please des...

Страница 212: ... 208 Installation 3 6 Ceiling floor indoor unit installation 3 6 1 Service space for indoor unit 3 6 2 Bolt pitch Ceiling installation Capacity Btu h D E 12 24K 983 220 30 36K 1200 220 48 60K 1565 220 Wall mounted installation ...

Страница 213: ...drain pump Remove the side board and the grille Select the position of installation hooks according to the hook holes positions showed in upper picture holes of Ø12mm 45 50mm deep at the selected positions on the ceiling Then embed the Install the tapping screws onto the wall Refer to picture below Ceiling installation The only installation method for the unit with drain pump Remove the side board...

Страница 214: ...Indoor unit installation 210 Installation Locate the hanging arm on the hanging screw bolt Prepare the mounting bolts on the unit Put the side panels and grilles back ...

Страница 215: ...pace for indoor unit a A place which provides the spaces around the indoor unit as required above in the diagram b A place where is no obstacle near the inlet and outlet area c A place which can bear the weight of the indoor unit d A place which allows the air filter to be removed downward e A place where the reception range is not exposed to direct sunlight f In the center of the room where possi...

Страница 216: ...t to the wall or in the ground to avoid accidental falling 3 7 2 2 Dismounting the lower front panel Please take off the air inlet grid before connecting the pipes wires Pull down the two knobs on the grille take off the two screws then the air inlet grille goes free 3 7 2 3 Take the Pipe Clip off before connecting the pipes and wiring fit it when these finished Use accessories to connect the pipe...

Страница 217: ...it d A place which allows the air filter to be removed downward e A place where the reception range is not exposed to direct sunlight f In the center of the room where possible 3 8 1 1 Please stand the unit in hard and flat ground Please reserve space for installation and maintenance 3 8 2 Installing 3 8 2 1 Anti falling To prevent the indoor unit from falling you must a Pay full attention to the ...

Страница 218: ...inside To dismount the air inlet grid hold both sides of the grid and pull it up let it slant downwards until the loop become straight Then removing the screws fastened the loop with the grid and the grid goes free 3 8 2 3 Take the Pipe Clip off before connecting the pipes and wiring fit it when these finished Use accessories to connect the pipes wires on both sides and back side ...

Страница 219: ...nance To prevent the indoor unit from falling you must a Pay full attention to the unit because its long outer shape makes it easy to fall unit to the wall or in the ground to avoid accidental falling floor standing indoor unit installation Service space for indoor unit A place which provides the spaces around the indoor unit as required above in the diagram A place where is no obstacle near the i...

Страница 220: ...inlet grid before connecting the pipes wires Pull down the two knobs on the grille take off the two screws then the air inlet grille goes free 3 9 2 3 Take the Pipe Clip off before connecting the pipes and wiring fit it when these finished Use accessories to connect the pipes wires on both sides and back side ...

Страница 221: ... exposed to direct sunlight f In the center of the room where possible 3 10 1 1 Please stand the unit in hard and flat ground Please reserve space for installation and maintenance 3 11 2 Installing 3 10 2 1 Anti falling To prevent the indoor unit from falling you must a Pay full attention to the unit because its long outer shape makes it easy to fall b Firmly fix the unit to the wall or in the gro...

Страница 222: ...it a A place which provides the spaces around the indoor unit as required above in the diagram b A place where is no obstacle near the inlet and outlet area c A place which can bear the weight of the indoor unit d A place which allows the air filter to be removed downward e A place where the reception range is not exposed to direct sunlight f In the center of the room where possible 3 11 1 1 Pleas...

Страница 223: ...t to the wall or in the ground to avoid accidental falling 3 11 2 2 Dismounting the lower front panel Please take off the air inlet grid before connecting the pipes wires Pull down the two knobs on the grille take off the two screws then the air inlet grille goes free 3 11 2 3 Take the Pipe Clip off before connecting the pipes and wiring fit it when these finished Use accessories to connect the pi...

Страница 224: ...Indoor unit installation 220 Installation ...

Страница 225: ... lifting it with a sling Never hold the inlet of the outdoor unit to prevent it from deforming Do not touch the fan with hands or other objects Do not lean it more than 45 and do not lay it sidelong Make concrete foundation according to the specifications of the outdoor units Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind More than...

Страница 226: ...the selected pipe with pipe cutter Make the section flat and smooth 9 0 Lean Crude Burr o 5 2 5 Insulate the copper pipe Before test operation the joint parts should not be heat insulated 5 2 6 Flare the pipe Insert a flare nut into the pipe before flaring the pipe According to the following table to flare the pipe Pipe diameter Flare dimension A mm Flare shape Min Max 1 4 6 35 8 3 8 7 R0 4 0 8 A ...

Страница 227: ...pe installation Install the drainage pipe as shown below and take measures against condensation Improperly installation could lead to leakage and eventually wet furniture and belongings 6 1 Installation principle Ensure at least 1 100 slope of the drainage pipe Adopt suitable pipe diameter Adopt nearby condensate water discharge 6 2 Key points of drainage water pipe installation 6 2 1 Considering ...

Страница 228: ...0 40 1440 PVC63 51 2760 PVC75 67 5710 PVC90 77 8280 Attention Adopt PVC40 or bigger pipe to be the main pipe 6 2 3 Individual design of drainage pipe system The drainage pipe of air conditioner shall be installed separately with other sewage pipe rainwater pipe and drainage pipe in building The drainage pipe of the indoor unit with water pump should be apart from the one without water pump 6 2 4 S...

Страница 229: ... or blow water phenomena Indoor unit More than 50mm More than 25mm Plug Water storage pipe 6 2 7 Lifting pipe setting of indoor unit with water pump The length of lifting pipe should not exceed the pump head of indoor unit water pump Pump head of big four way cassette 750mm Pump head of compact four way cassette 500mm The drainage pipe should be set down inclined after the lifting pipe immediately...

Страница 230: ...d slowly infuse about 2000ml water through the water test hole be sure that the water will not touch the motor of drainage pump 2 2 Power on and let the air conditioner operate for cooling Check operation status of drainage pump and then connect the plug of water level switch check the operation sound of water pump and observe whether the water can discharge through the transparent hard pipe at dr...

Страница 231: ...pipe and keep vacuum pump running for 1hour vacuum degree of vacuum pump shall be reached 755mmHg 2 If the vacuum degree of vacuum pump could not reach 755mmHg after 1 hour of drying it indicates that there is moisture or leakage in pipeline system and need to go on with drying for half an hour 3 If the vacuum degree of vacuum pump still could not reach 755mmHg after 1 5 hours of drying check whet...

Страница 232: ...rging The air in the flexible pipe and manifold gauge should be exhausted After finished refrigerant recharge process check whether there is refrigerant leakage at the connection joint part Using gas leakage detector or soap water to detect 9 Engineering of insulation 9 1 Insulation of refrigerant pipe 9 1 1 Operational procedure of refrigerant pipe insulation Cut the suitable pipe insulation exce...

Страница 233: ...pe The insulation material should be flame retardant material the flame retardancy of the material should be selected according to the local law Thickness of insulation layer is usually above 10mm Use specific glue to paste the seam of insulation material and then bind with adhesive tape The width of tape shall not be less than 5cm Make sure it is firm and avoid dew 9 2 4 Installation and highligh...

Страница 234: ...orrectly The length of the tubing and the added stow capacity of the refrigerant have been recorded The power voltage fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the outdoor and indoor units The gas side and liquid side stop values are both opened The air conditioner is pre heated by turning on the power 11 3 Test operation Set the air conditioner ...

Страница 235: ...Electrical Control Electrical Control 231 Part 5 Electrical Control System 1 Electrical Control Function 232 2 Troubleshooting 237 3 Controller 253 ...

Страница 236: ...ff 1 2 5 Over current protection for 48 60K models When compressor is running if the current is over twice of the rated for 3 seconds the compressor will stop and an error code will be displayed on the outdoor PCB If the current becomes normal the compressor will restart after 3 minutes 1 3 Operation Modes and Functions 1 3 1 Fan mode Outdoor fan and compressor cease operation Temperature setting ...

Страница 237: ...the compressor stops 1 3 2 5 Condenser high temperature T3 protection excluding 12 36k cooling only models T3 Off On When condenser temperature exceeds the preset value the compressor stops 1 3 3 Heating Mode For heat pump models 1 3 3 1 Compressor Running Guidelines Once the compressor starts up it keeps running 7 minutes then it will follow the below rules When T1 Ts is higher than setting value...

Страница 238: ... other units T1 Ts High Low Medium 1 3 3 4 Defrosting mode the unit enters the defrosting mode according to the value of T3 and T4 as well as the compressor running time Defrosting action For 12 30K floor standing units For 12 30 other units For 36 60K In defrosting mode the compressor continues to run the indoor and outdoor motor stops 1 3 3 5 High evaporator coil temp T2 protection For floor sta...

Страница 239: ... 3 6 2 Timer On The machine turns on automatically at the preset time 1 3 6 3 Timer Off The machine turns off automatically at the preset time 1 3 6 4 Timer On Off The machine turns on automatically at the preset On Time and then turns off automatically at the preset Off Time 1 3 6 5 Timer Off On The machine turns on automatically at the preset Off Time and then turns off automatically at the pres...

Страница 240: ... after power returns 1 3 9 Drain Pump Control For Duct and Cassette Use the water level switch to control drain pump The system checks the water level every 5 seconds When the A C operates in cooling including auto cooling or forced cooling mode the pump begins running immediately and continuously until cooling stops If the water level increases up to the control point the LED displays an alarm co...

Страница 241: ...uper slim cassette 2 1 3 Display board of auto lifting panel of 4 way cassette 2 1 4 Display board of ceiling Floor OPERATION TIMER DEF FAN ALARM Temporary button Operation lamp Timer indicator Infrared signal receiver Alarm indicator PRE DEF indicator cooling and heating type or fan only indicator cooling only type MANUAL Display digital tube ...

Страница 242: ...Troubleshooting 238 Electrical Control 2 1 5 Display board of Compact cassette 2 1 6 Display board of GA floor standing ...

Страница 243: ...Troubleshooting Electrical Control 239 2 1 7 Display board of M floor standing 2 1 8 Display board of J2 floor standing ...

Страница 244: ...hooting 240 2 1 9 Display board of S2 floor 2 1 10 Display board of Troubleshooting Display board of S2 floor Display board of S4 Display board of S2 floor standing S4 floor standing standing standing Electrical Electrical Control Control ...

Страница 245: ... 4 Indoor EEPROM malfunction X X E7 5 Water level alarm X X X E8 6 Communication error between auto lifting panel and slim cassette X F0 7 Auto lifting panel is faulty for slim cassettes with an auto lifting panel X F1 8 Auto lifting panel is not closed for slim cassettes with an auto lifting panel X O F2 O on X off flash at 5Hz For Compact cassette Type NO Malfunction Running lamp Timer lamp Defr...

Страница 246: ...condenser temperature protection P9 Anti cold wind for S2 it means defrosting E1 T1 temperature sensor open or short circuit E2 T2 temperature sensor open or short circuit E3 T3 temperature sensor open or short circuit E6 Outdoor unit malfunction HS Defrosting P0 Communication malfunction between indoor main PCB and display PCB J2 S4 ...

Страница 247: ...e protection Flash Flash Off Trouble Overload of current Off Off Flash Trouble T3 temperature sensor open or short circuit Off Flash Flash Trouble Temperature sensor open or short circuit of T4 or T5 or high pressure protection Off Flash Off Trouble High temperature protection of condenser Flash Flash Flash Note 1 If the LED1 LED3 are flashing slowly means the system is stand by 2 T3 Outdoor conde...

Страница 248: ...Troubleshooting 244 Electrical Control 2 3 Solving steps for typical malfunction 1 For indoor unit a T1 or T2 temperature sensor open or short circuit b T3 temperature sensor open or short circuit ...

Страница 249: ...ndoor EEPROM malfunction EEPROM An electrically erasable programmable read only memory whose contents can be erased and reprogrammed using a pulsed voltage d Water level alarm e Communication malfunction between indoor main PCB and display PCB ...

Страница 250: ...Troubleshooting 246 Electrical Control For the super slim cassette with up down panel a Communication error between auto lifting panel and slim cassette b Auto lifting panel is faulty ...

Страница 251: ...er supply and terminal is the voltage in outdoor terminal is 3 phase 380 415V Outdoor PCB is defective Yes Yes 2 For the outdoor unit a Phase sequence error b Lack of phase Phase sequence error Change the order of two of the wires to power supply Switch on the unit again If the problem cannot be solved the outdoor PCB is defective ...

Страница 252: ...urn on the units and check if the problem remains Yes Check if the voltage of the power supply is too low No Replace the outdoor fan Yes Check if the capillary is blocked No No There is some air mixed inside the refrigerant system Evacuate the system and recharge refrigerant Regulate the power supply Correct the operation condition Replace the capillary Check if the outdoor fan is defective Replac...

Страница 253: ...dix 1 Is it normal No Protection of pressure or temp Is it k1 or K2 open Is temp protective switch K1 open Possible reason 1 The wires is loose to K1 2 Air or other gas in the refrigerant 3 Heat exchanger is dirty 4 Outdoor fan or fan blade is defective 5 Outdoor unit is in bad ventilation 6 Refrigerant is leakage Is pressure protective switch K2 open Yes Yes Yes Possible reason 1 The wires is loo...

Страница 254: ...otection of condenser Check the resistance of the temp sensor according to Appendix 1 is it normal Possible reason 1 Air or other gas in the refrigerant 2 Heat exchanger is dirty 3 Outdoor fan or fan blade is defective 4 Outdoor unit is bad ventilation 5 Refrigerant is leakage Replace the sensor No Yes ...

Страница 255: ...13059 76 1 34105 116 0 40060 3 41 5878 37 5 87359 77 1 29078 117 0 38991 2 39 8239 38 5 62961 78 1 25423 118 0 37956 1 37 1988 39 5 39689 79 1 21330 119 0 36954 0 35 2024 40 5 17519 80 1 17393 120 0 35982 1 33 3269 41 4 96392 81 1 13604 121 0 35042 2 31 5635 42 4 76253 82 1 09958 122 0 3413 3 29 9058 43 4 57050 83 1 06448 123 0 33246 4 28 3459 44 4 38736 84 1 03069 124 0 32390 5 26 8778 45 4 21263...

Страница 256: ... 5 234 9 35 35 78 75 8 084 115 2 422 4 222 8 36 34 32 76 7 82 116 2 357 3 211 4 37 32 94 77 7 566 117 2 294 2 200 7 38 31 62 78 7 321 118 2 233 1 190 5 39 30 36 79 7 086 119 2 174 0 180 9 40 29 15 80 6 859 120 2 117 1 171 9 41 28 81 6 641 121 2 061 2 163 3 42 26 9 82 6 43 122 2 007 3 155 2 43 25 86 83 6 228 123 1 955 4 147 6 44 24 85 84 6 033 124 1 905 5 140 4 45 23 89 85 5 844 125 1 856 6 133 5 4...

Страница 257: ... Increase the set temp Keeping pressing will increase the temp with 1 Once pressing running mode will be selected in the following sequenc NOTE No heating mode for cool only type unit Used to stop or start horizontal louver movement The louver will swing up and down Used to set the desired up down air flow direction The louver changes 6 degree in Used to stop or start vertical louver movement AUTO...

Страница 258: ...mote controller display when the lock function is activated inner located Once the recessed RESET button is pressed all of the current setting cancelled and the controller will return to the initial settings Lowest Voltage of CPU Emitting Signal Temperature Range Introduction of Function Buttons on the Remote Controller AUTO Press the Mode and Fan speed button simultaneously for 2 seconds controls...

Страница 259: ...ated The moving angle of the louver is 6o for each press Keep pressing the button to move the louver to the desired position If keep pressing the button the auto swing feature of the louver is activated The horizontal louver would swing up down automatically When press the button once and quickly the air flow direc the louver is activated The moving angle of the louver is 6o for each press Keep pr...

Страница 260: ...ll increase the temp with 1 For time ON setting Once pressing this button the time will i set time exceeds 10 hours pressing the button will increase the time by 1 hour Adjusting the figure to 0 00 Press this button to activate the Energy This function is available on COOL HEAT or AUTO mode only and maintain the most comfortable For time OFF setting Once pressing this button the time will increase...

Страница 261: ...essing this button the time will increase by 0 5 hour When the set time exceeds 10 hours pressing the button will increase the time by 1 hour Adjusting the figure to 0 00 will cancel time ON setting 11 SLEEP Press this button to go into the Energy Saving operation mode Press it again to cancel This function is only can be used on COOL HEAT and AUTO mode and maintain the most comfortable temperatur...

Страница 262: ...each press If cancel this function just set it to 0 0 4 Follow me button When under cool heat and auto mode press this button follow me function is active Press again this function is ineffective 5 Electrical heater button If press this button in heat mode electrical heater function become ineffective 6 Reset button hidden Use a 1mm stick to press in the little hole then the current setting is can...

Страница 263: ...the wi controller does not accept any operation except that of the LOCK button Use the lock mode when you want to prevent setting from being changed accidentally or play fully Push the LOCK button again when controller Operation mode indication When press MODE button the following mode can be selected in circle Auto Cool Dry Heat Fan only Auto skipped Timer When adjust setting on time or only on t...

Страница 264: ...r unit switch board then connecting the terminal 5v GND Run in the switch board to C D E respectively should be a little longer as to take away the switch board easily for maintenance The connecting wire should be a little longer as to take away the controller easily for maintenance The wired controller will reset to factory setting with auto mode auto fan and 24 And this may cause inconsistent di...

Отзывы: