ABNORMAL PHENOMENON

Please read the following illustration before applying for the service:

Troubles 

Causes

Fan function stop automatically to defrost. It
is the start and stop sound of the electro-
magnetic valve.

From outdoor unit 

   white cold fog and condensing dew.
   hiss and poop are heard.

Hiss for once.

Hiss and poop are heard.

Abnormal smell blown out.

Operation lamp flashes.

Noise, hydrometeor and 
cold air appear when the
running stops.

Ksha

can be heard

 when start.

From indoor 
unit

N

o

m

a

lf

u

n

c

ti

o

n

Insufficient cooling

No operation

Insufficient heating 

If no power.
If the fuse is blown.
If starting the protection device (the operation 
lamp lights).
If the timer is on the set time.
If choosing the cooling and heating simultan-
eously.

Stop running automatically.

If the timer reached the set time.

C

h

e

c

k

 i

a

g

a

in

Do not

work

If the outdoor unit air inlet or outlet is 
blocked.
If the doors and windows are open.
If the dust filter is choked by collective dust.
If the air louver is in the right place.
If the fan speed is shifted in low or if the 
shift is under FAN mode.
If the setting temperature is appropriate.

At the beginning and ending of the running 
process, sounds like water flow in valve 
appears, and be enhanced at the first 2~3 
minutes, this is refrigerant flow sound.
Slight hiss and poop are caused by mild 
flexing of the heat exchanger as temperature 
changes.
Pieces of the wall, carpet, furniture, cloth, 
cigarette and cosmetics adhere to the unit.
Connect to the power after the power cut.
Other equipments heating process stops the
cooling operation.
The operator sets an opposite mode against 
the fixed cooling and heating mode.
The refrigerant will suddenly move to avoid
resorting in the indoor unit, then caused 
kak  sounds.Hydrometeor or cold air appears 
when other indoor unit is heating or cooling.
The sound of the expansion valve when
supplied power.

13

If the air- conditioner is found any failures as mentioned below, please turn off the power
immediately. Then contact the local dealer.

ON/OFF operation is not valid.
Fuse or leakage protector frequently blown.
Some matter or water falls into  the unit.

Still no operation after checking the protector(P4).
Quite different from other indoor unit or ordinary
state.

Содержание MUB-18HRDN1

Страница 1: ...Owner s Manual Please read this owner s manual carefully before using the air conditioner and keep this manual for the future reference AIR CONDITIONER...

Страница 2: ...1 1 2 Note Before 3 4 5 6 7 8 Abnomal Phenomenon Safety Precaution Operation Caution Parts Identification Operation Adjustment Air Flow Direction Maintenance 3 5 6 8 9 10 13 CONTENTS...

Страница 3: ...lease use the specified product Accessories must be specified Defective grounding may cause electrical shock Grounding Markers Icons Icons Indication The sign shows the risk of death or serious injury...

Страница 4: ...e Ensure the creepage protection switch Ensure the installation place User caution Ventilation should be operated regularly when using with the flammable appliance Insufficient ventilation will cause...

Страница 5: ...s the defined value Using the iron wire or brass wire as fuse can cause the fire and malfunction The power must use the specified circuit under the rated voltage Use the right fuse Note Before Operati...

Страница 6: ...air filter is too dirty The air intake and the air outlet of the indoor unit are blocked Fan Runs after the Indoor Unit Stopped To protect the machine one of the indoor units which stops the running...

Страница 7: ...cooling Do not disconnect the power Do not disconnect the power when the unit is in operation Please control it with the remote controller To protect the compressor please turn on the power switch 12...

Страница 8: ...osing the Air Grille Air Intake Intake air from here Air Filter Filter the dust in the intake air Two direction or Three direction Air Outlet For the detailed information please consult your local dea...

Страница 9: ...in the air Air Intake Intake room air here Lock Buckle For closing the air intake grille Air Outlet Connect the duct 7 Thin Duct Ceiling Type Indoor unit Electric control box Air Intake Intake room ai...

Страница 10: ...old Cooling Suggested Temperature Heating Close the door window Close the door window Do not let the heat cool air leak from the door widow Adjust the air out direction with using the air out louver T...

Страница 11: ...ling operation the air flow down will cause condensing dew on the air outlet and louver surface Four Way Cassette Type Cooling operation Heating operation When using the panel with auto louver press S...

Страница 12: ...reased If the accumulated dust is too heavy to be cleaned please replace the filter with a new one the replaceable air filter is an optional fitting 1 Take out the air in grill Four Way Cassette Type...

Страница 13: ...rack or deform To avoid the risk of electrical shock or fire do not let water fall into the indoor unit Never wipe the air flow louver violently An air conditioner without air filter can not expel the...

Страница 14: ...grounding wire is not broken off and is connected well 2 Restore the air filter and the front panel The air filter and the front panel must be fixed to the original position after having been cleaned...

Страница 15: ...eed is shifted in low or if the shift is under FAN mode If the setting temperature is appropriate At the beginning and ending of the running process sounds like water flow in valve appears and be enha...

Страница 16: ...MDV06U 015aW 2200017221...

Отзывы: