background image

7

Manul operation can be used temporarily in case the remote controller is disable or maintenance
necessary.

OPERATING INSTRUCTIONS

Manual operation

Manual control

button

Front panel

AUTO/COOL

NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.

Operating temperature

Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
Push the button until the AUTO indicator
is lit, the unit will work in forced AUTO
mode (the default setting temperature
is 24

).

Close the panel firmly to its original
position.

Once you push the manual button, the
operation mode is shifted in an order as:
AUTO, COOL, OFF.
Push the manual button until the
indicator light flashes rapidly (five times
per second), the unit now is operating in
forced COOL mode. This is used for
testing purposes only.
To restore the remote controller operation,
use the remote controller directly.

POWER

CAUTION:

1

3

2

Mode

Cooling operation

Heating operation Drying operation

Temperature

1. If air conditioner is used outside of the above conditions, certain safety protection

features may come into operation and cause the unit to function abnormally.

2. Room relative humidity less than 80%. If the air conditioner operates in excess of this

figure, the surface of the air conditioner may attract condensation. Please sets the vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

3. Optimum performance will be achieved within these operating temperature.

Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature is
below 0 C, we strongly recommend you to keep the machine plugged in order to guarantee it
running smoothly.

O

Room temperature

Outdoor temperature

>17 C

18 C

50 C

<30 C

-15 C

34 C

10 C

50 C

CAUTION:

~

~

~

( -15 C

50 C:For the models with

low temperature cooling system)

~

>10 C

Содержание MSX-09HRDN1QC2

Страница 1: ...aintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common...

Страница 2: ...rd is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Страница 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Страница 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Страница 5: ...ond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off t...

Страница 6: ...louver 7 Vertical louver 8 Air filter 9 Manual control button 10 11 Remote controller 12 Connecting pipe 13 Drain hose 14 Power cord Remote controller holder 15 16 17 Stop valve Connecting cable Conne...

Страница 7: ...tion is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit Note SEL...

Страница 8: ...ed for testing purposes only To restore the remote controller operation use the remote controller directly POWER CAUTION 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 I...

Страница 9: ...on again To set the horizontal air flow direction left right To automatically swing the air flow direction up down The DIRECTION SWING button will be disabled when the air conditioner is not in operat...

Страница 10: ...perature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Cool...

Страница 11: ...system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter...

Страница 12: ...to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the Silver Ion filter B...

Страница 13: ...ow hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak sound when the compres...

Страница 14: ...y the air conditioner we suggest you use a supplementary heating device 9 Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores...

Страница 15: ...d Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Re...

Страница 16: ...CS436 U...

Отзывы: