Special function

Air quality is the key to comfort, this air
conditioner is equipped with Ionizer or
Plasma Dust Collector(Depending on models).
Ionizer can generate abundant anions to fill
the room with refreshing and nature air. Your
whole family will enjoy a natural, pure and
healthy air everyday. The Plasma Dust Collector
can generate an ionization zone. The air is
converted to plasma as it passes the high
voltage ion generator. 95% of the dust, smoke,
and pollen particles are attracted to the
electrostatic filter.

CLEAN AIR function

Function used after the Shut Down of
cooling operation to clean the Evaporator
and keep it as fresh for the next operation.
This function is easy to be operated as it is
accessed through the Remote Controller.
For cooling only models, the unit will
operate under FAN ONLY mode at LOW
fan speed for 30 minutes, and then stop
the operation and the unit turn off.
For cooling & heating models, the unit will
operate : FAN ONLY mode at Low fan
speed(13 minutes)--Heating operation
with LOW fan speed(1 minute)---FAN
ONLY operation(2 minutes)--
Stop Operation---Turn off the unit.

This function is only available under
COOL(AUTO COOL, FORCED COOL)
and DRY mode.
Before select the function, it is recomm-
ended to run the air conditioner under
Cooling operation for about half an hour.
Once the Self Clean function is activated,
all TIMER setting will be cancelled.
During Self Clean operation, when press
the SELF CLEAN button on the remote
controller again will stop the operation
and turn off the unit.

Note:

SELF CLEAN function

Follow Me function

To activate the Follow Me feature, point the
remote control towards the unit and press the
Follow Me button. T

If the unit does not receive the

Follow Me signal during any 7 minute interval,
the unit will beep to indicate the Follow Me
mode has ended.

he remote display is actual

temperature at its location. The remote control
will send this signal to the air conditioner every
3 minutes interval until press the Follow Me
button again.

The remote control serves as a remote
thermostat allowing for the precise
temperature control at its location.

OPERATING INSTRUCTIONS

6

TIMER display

Displayed

during Timer operation.

CLEAN AIR display(optional)

Displayed when Ionizer or Plasma dust
collector(depending on models) is activated.

TURBO operation display

Displayed when select TURBO function
on cooling operation or on heating
operation.

DIGITAL DISPLAY

Displays the current setting temper-
ature when the air conditioner is in
operation. When SELF CLEAN
feature is activated, it displays

.

FAN SPEED display

Displayed the selected fan speed:
AUTO(nothing) and three fan speed
levels: LOW(

), MED(

) and

HIGH(

).

,,

, ,

This display is separated into five
zones. The zones illuminate based on
the compressor current frequency. For
example, higher frequency will
illuminate more zones.

Operation Frequency display

Содержание MSX-09HRDN1QC2

Страница 1: ...aintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common...

Страница 2: ...rd is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Страница 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Страница 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Страница 5: ...ond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off t...

Страница 6: ...louver 7 Vertical louver 8 Air filter 9 Manual control button 10 11 Remote controller 12 Connecting pipe 13 Drain hose 14 Power cord Remote controller holder 15 16 17 Stop valve Connecting cable Conne...

Страница 7: ...tion is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit Note SEL...

Страница 8: ...ed for testing purposes only To restore the remote controller operation use the remote controller directly POWER CAUTION 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 I...

Страница 9: ...on again To set the horizontal air flow direction left right To automatically swing the air flow direction up down The DIRECTION SWING button will be disabled when the air conditioner is not in operat...

Страница 10: ...perature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Cool...

Страница 11: ...system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter...

Страница 12: ...to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the Silver Ion filter B...

Страница 13: ...ow hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak sound when the compres...

Страница 14: ...y the air conditioner we suggest you use a supplementary heating device 9 Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores...

Страница 15: ...d Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Re...

Страница 16: ...CS436 U...

Отзывы: