Service manual 

- 2 - 

 

unit is so equipped.) 

There is risk of physical injury, electric shock, or product 
failure. 

„

 

When the product is soaked (flooded or submerged), 

contact an Authorized service center. 

There is risk of fire or electric shock. 

„

 

Be caution that water could not enter the product. 

There is risk of fire, electric shock, or product damage. 

„

 

Ventilate the product from time to time when 

operating it together with a stove, etc. 

There is risk of fire or electric shock. 

„

 

Turn the main power off when cleaning or 

maintaining the product.   

There is risk of electric shock. 

„

 

When the product is not be used for a long time, 

disconnect the power supply plug or turn off the 

breaker. 

There is risk of product damage or failure, or unintended 
operation. 

„

 

Take care to ensure that nobody could step on or fall 

onto the outdoor unit. 

This could result in personal injury and product damage. 
 
 

¾

 

CAUTION 

„

 

Always check for gas (refrigerant) leakage after 

installation or repair of product. 

Low refrigerant levels may cause failure of product. 

„

 

Install the drain hose to ensure that water is drained 

away properly. 

A bad connection may cause water leakage. 

„

 

Keep level even when installing the product. 

To avoid vibration of water leakage. 

„

 

Do not install the product where the noise or hot air 

from the outdoor unit could damage the 

neighborhoods. 

It may cause a problem for your neighbors. 

„

 

Use two or more people to lift and transport the 

product. 

Avoid personal injury. 

„

 

Do not install the product where it will be exposed to 

sea wind (salt spray) directly. 

It may cause corrosion on the product. Corrosion, 
particularly on the condenser and evaporator fins, could 
cause product malfunction or inefficient operation. 
 
 

 

¾

 

Operational 

„

 

Do not expose the skin directly to cool air for long 

periods of time. (Do not sit in the draft). 

This could harm to your health. 

„

 

Do not use the product for special purposes, such 

as preserving foods, works of art, etc. It is a 

consumer air conditioner, not a precision refrigerant 

system. 

There is risk of damage or loss of property. 

„

 

Do not block the inlet or outlet of air flow. 

It may cause product failure. 

„

 

Use a soft cloth to clean. Do not use harsh 

detergents, solvents, etc. 

There is risk of fire, electric shock, or damage to the 
plastic parts of the product. 

„

 

Do not touch the metal parts of the product when 

removing the air filter. They are very sharp. 

There is risk of personal injury. 

„

 

Do not step on pr put anything on the product. 

(outdoor units) 

There is risk of personal injury and failure of product. 

„

 

Always insert the filter securely. Clean the filter 

every two weeks or more often if necessary. 

A dirty filter reduces the efficiency of the air conditioner 
and could cause product malfunction or damage. 

„

 

Do not insert hands or other object through air inlet 

or outlet while the product is operated. 

There are sharp and moving parts that could cause 
personal injury. 

„

 

Do not drink the water drained from the product. 

It is not sanitary could cause serious health issues. 

„

 

Use a firm stool or ladder when cleaning or 

maintaining the product. 

Be careful and avoid personal injury. 

„

 

Replace the all batteries in the remote control with 

new ones of the same type. Do not mix old and mew 

batteries or different types of batteries. 

There is risk of fire or explosion. 

„

 

Do not recharge or disassemble the batteries. Do not 

dispose of batteries in a fire. 

They may burn of explode. 

„

 

If the liquid from the batteries gets onto your skin or 

clothes, wash it well with clean water. Do not use the 

remote of the batteries have leaked. 

The chemical in batteries could cause burns or other 
health hazards. 

 

Содержание MSG-30CRN1-QB9P

Страница 1: ...MSG 30CRN1 QB9P MSG 30HRN1 QB9P MSG 36CRN1 QB8P MSG 36HRN1 QB8P...

Страница 2: ......

Страница 3: ...length and the elevation 13 8 4 Air purging of the piping and indoor unit 13 8 5 Pumping down Re installation 15 8 6 Re air purging Re installation 16 8 7 Balance refrigerant of the 2 way 3 way valve...

Страница 4: ...ubleshooting 31 12 3 Diagnostic chart 32 12 4 Resetting phenomenon often occurs during operation 33 12 5 Operation lamp flashes and Timer lamp off 33 12 6 Operation lamp flashes and Timer lamp on 33 1...

Страница 5: ...Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not let the air...

Страница 6: ...tional Do not expose the skin directly to cool air for long periods of time Do not sit in the draft This could harm to your health Do not use the product for special purposes such as preserving foods...

Страница 7: ...r each operation mode The unit will decide the louver direction according to operation mode Two direction air vane The fan is turn to low speed cooling heating The unit will be turn off after seven ho...

Страница 8: ...unit run more quietly Low noise air flow system The hydrophilic fin can improve the heating efficiency at operation mode Hydrophilic aluminum fin It is only operated in the heating operation mode exce...

Страница 9: ...ervice manual 5 3 Dimension 3 1 Indoor unit Dimension Mode W H L 28K 1250 325 230 36K 1250 325 230 3 2 Outdoor unit Dimension Mode W H D L1 L2 L3 28K 895 860 330 560 360 735 36K 895 860 330 560 360 73...

Страница 10: ...00 m3 h 1350 1200 1050 1350 1200 1050 dB A 52 49 45 52 49 45 Model YDK100 6 YDK100 6 Brand Welling Welling Input W 169 169 Capacitor uF 5 5 Speed r min 900 900 m 3 h 1900 1900 dB A 60 60 g R410A 2450...

Страница 11: ...0 1200 1050 1350 1200 1050 dB A 52 49 45 52 49 45 Model YDK100 6 YDK100 6 Brand Welling Welling Input W 169 169 Capacitor uF 5 5 Speed r min 900 900 m 3 h 3000 3000 dB A 60 60 g 2450 2450 MPa 4 2 4 2...

Страница 12: ...Service manual 8 5 Refrigerant cycle diagram Cooling only Heat pump mode...

Страница 13: ...from the continuous operation under constant air temperature conditions However excludes the initial pull down stage 6 2 Heating operation Indoor air temp DB Outdoor unit air temp DB Note The chart i...

Страница 14: ...Service manual 10 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...

Страница 15: ...Service manual 11 7 2 Wiring diagram 7 2 1 Cooling and heating pump mode indoor unit MSG 30C H RN1 QB9P MSG 36C H RN1 QB8P 7 2 2 Cooling mode outdoor unit MSG 28CRN1 QB9P MSG 36CRN1 QB8P...

Страница 16: ...tion details 8 1 Wrench torque sheet for installation Torque mm inch Kg m 9 52 3 8 4 2 16 0 5 8 6 6 Outside diameter 8 2 Connecting the cables The power cord of connect should be selected according to...

Страница 17: ...r 5 7 meters 8 4 Air purging of the piping and indoor unit Required tools Hexagonal wrench adjustable wrench torque wrenches wrench to hold the joints and gas leak detector Note The air in the indoor...

Страница 18: ...wait for one minute 5 Use torque wrench to tighten the service port cap to a torque of 1 8 kg m 18n m 6 Set the 3 way valve to the opened position 7 Mounted the valve stem nuts to the 2 way and 3 way...

Страница 19: ...charge hose with the push pin to the gas service port 4 Air purging of the charge hose Open the low pressure valve on the charge set slightly to purge air from the charge hose 5 Set the 2 way valve to...

Страница 20: ...1 minutes repeat 3 times After purging the air use a torque wrench to tighten the flare nut to on the 2 way valve 4 Check the gas leakage Check the flare connections for gas leakage 5 Discharge the r...

Страница 21: ...he service port 3 Open the valves Low side on the charge set and discharge the refrigerant until the gauge indicates 0 05 to 0 1 Mpa If there is no air in the refrigeration cycle the pressure when the...

Страница 22: ...has moved toward 0 1 Mpa 76 cmHg vacuum of 4 mmHg or less 3 Close the valve Low side on the charge set turn off the vacuum pump and confirm that the gauge needle does not move approximately 5 minutes...

Страница 23: ...e specified amount of refrigerant if can be charged with a little at a time approximately 150g each time0 while operating the air conditioner in the cooling cycle however one time is not sufficient wa...

Страница 24: ...88 7 40 6 86 6 31 5 90 5 47 15 C W Sensitive capacity kW 5 75 5 52 5 18 4 79 4 50 4 21 Input kW 2 74 2 89 3 01 3 25 3 61 3 73 24 C D Total capacity kW 8 53 8 15 7 62 7 20 6 71 6 19 17 C W Sensitive ca...

Страница 25: ...7 90 7 38 6 85 15 C W Sensitive capacity kW 7 21 6 92 6 48 6 00 5 64 5 28 Input kW 3 52 3 72 3 87 4 18 4 65 4 80 24 C D Total capacity kW 10 69 10 21 9 54 9 02 8 41 7 75 17 C W Sensitive capacity kW 7...

Страница 26: ...ature TE2 Anti cold wind from Breeze to Setting Fan Speed temperature TE3 Anti cold wind from Setting Fan Speed to Breeze temperature TE4 Anti cold wind from Breeze to Fan Off temperature TE5 Evaporat...

Страница 27: ...Service manual 23 Current protection High temperature protection of indoor heat exchanger at heating mode Auto defrosting and heating recovery at heating mode Anti cold air at heating mode...

Страница 28: ...normal operation automatically 10 4 4 Cross Zero signal error warning If there is no Cross Zero signals in 4 minutes the unit stops and LED displays failure information and can t returns to normal ope...

Страница 29: ...compressor if the compressor changed into non heating mode or turned off 4 way valve doesn t delay in dehumidifying mode 10 8 2 Generally the outdoor fan is turned off with the on off action of compre...

Страница 30: ...7 The louver opens to Standard Angle ANGLHEAT when power is on for the first time 10 9 Defrosting mode available for heating mode 10 9 1 Defrosting condition Defrost starts when either of the followin...

Страница 31: ...indoor fan blows automatically in corresponding selected mode 10 10 3 The motion of indoor fan s blade should accord with the selected operation mode 10 10 4 One mode should be carried out for at lea...

Страница 32: ...will maintain as a constant and the fan speed is kept at low speed 10 12 3 Heating The set temperature decrease 1 per hour Two hours later the set temperature will maintain as a constant and the air...

Страница 33: ...ower returns 11 Model and Parameters 1PH 198V 253V 50Hz Model MSG 28CRN1 QB9PMSG 28HRN1 QB9PMSG 36CRN1 QB8P MSG 36HRN1 QB8P I3SEC A 26 26 34 34 I5MIN A 24 24 32 32 IFAN A 20 20 25 25 IDEFROST A 18 18...

Страница 34: ...icator illuminates then TIMER is set ON PRE DEF indicator For cooling heating mode only The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating At this time PRE...

Страница 35: ...or occurs 4 times X EEROM error On No over zero signal r Extinguish Flash at 5Hz For heat pump mode Failure phenomenon Operation lamp Timer lamp Defrosting lamp Over current protection of the compress...

Страница 36: ...Service manual 32 12 3 Diagnostic chart After energizing no indicator is lighted and the air conditioner can t be operated...

Страница 37: ...That is automatically entering to the status when power is on The reason is that the instantaneous voltage of main chip is less than 4 5V Check according to the following procedure 12 5 Operation lamp...

Страница 38: ...12 8 Operation lamp on and Timer lamp flashes EEROM error indoor PCB is defective 12 9 Operation lamp flashes Timer lamp flashes This is alarm signal when the main chip can t detect over zero signal...

Страница 39: ...25 10 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31 7 6241 58 2 5397 5 26...