37
8.4.10.3 After starting the Clean Air function, the ionizer can work only when the indoor fan motor is
running. If the indoor fan motor is off, the ionizer also stops working, even though the Clean Air
function is available.
8.4.10.4 Switching the running mode will not stop the ionizer. When turning off the aircon, the ionizer is
also turned off.
8.4.11 Automatic panel function (for 18K unit optional)
8.4.11.1 The automatic panel is forced to turn to the closing direction at an angle of 60
°
when the unit
is getting through the power, and this action is not affected by any signal from remote controller.
8.4.11.2 When the unit is turned on, the panel is opened automatically at an angle of 60
°
, then the
horizontal louver will be opened.
8.4.11.3 When the unit is turned off, the panel is closed automatically at an angle of 60
°
, then the
horizontal louver will be closed.
8.4.11.4 If the panel needs moving when the horizontal louver is in action, the unit will stop the
horizontal louver and then carry out the action of the panel. After ending the action of the panel, the
horizontal louver will continue its action.
9. Troubleshooting
Safety
Because of t capacitors in PCB and relative circuit in outdoor unit, even shut down the power supply.
Electricity power still are kept in capacitors, do not forget to discharge the electricity power in capacitor.
Electrolytic Capacitors
(HIGH VOLTAGE! CAUTION!)
Содержание MS9V-09HRDN1-QC2 9V Series