R410A All DC Inverter Mini VRF MCAC-VTSM-2016-10
88 Troubleshooting
4.15.2 Principle of DC inverter
①
380-415V AC power supply change to DC power supply after bridge rectifier.
②
Contactor is open the current across the PTC to charge capacitor, after 5 seconds the contactor closed.
③
The capacitor output steady 540V DC power supply for inverter module P N terminals.
4.15.3 L0 troubleshooting
Condition 1: L0 error appears immediately when the outdoor unit is power on.
L0
Communication wires between main
PCB and inverter module (10 pins) are
not connected properly
1
Yes
Ensure communication wires are
connected properly
No
Inverter module is failed
2
Yes
No
Voltage between F0 and G on
communication wire terminal (10 pins)
on main PCB is too low
2
Yes
Replace the inverter module
Notes:
1. Communication wire between main PCB and inverter module:
Communication wire terminal on main PCB
Communication wire
Communication wire terminal on inverter module
2. Measure the resistance between PU/PW/PV/UN/VN/WN on inverter module.
If the resistances are infinite, the U V W terminals are normal.
If the resistances are zero, the U V W terminals have failed.
3. The normal voltage between F0 and GND is 3.1V.
Power
supply
(380V
AC)
A
B
C
Bridge
rectifier
PTC
Contactor
Inductor
Capacitor
Inverter module
(V
P-N
: 540V DC)
U
V
W
Compressor
P
N
V
normal
= 3.1V
○
3
○
1
○
2
Содержание MDV-V120W/DRN1
Страница 3: ...R410A All DC Inverter Mini VRF MCAC VTSM 2016 10...
Страница 20: ...MCAC VTSM 2016 10 R410A All DC Inverter Mini VRF Specifications Performance 17 5 Wiring Diagrams For 12 16kW...
Страница 21: ...R410A All DC Inverter Mini VRF MCAC VTSM 2016 10 18 Specifications Performance For 18kW...
Страница 22: ...MCAC VTSM 2016 10 R410A All DC Inverter Mini VRF Specifications Performance 19 6 Field Wiring...