Midea MDS70-V032_A0431-EU18-P1 Скачать руководство пользователя страница 5

5

Ordinary

 

Information

1.Please

 

unplug

 

the

 

power

 

cord

 

when

 

you

 

disassemble

 

or

 

maintain

 

the

 

product

2.Please

 

use

 

the

 

regulation

 

connector

 

lug

 

between

 

the

 

wires

 

as

 

much

 

as

 

possible.

 

Then

 

crimp

 

them

 

firmly by

 

the

 

proper

 

tools

 

and

 

bundle

 

them

 

by

 

the

 

insulating

 

tape;

3.When

 

you

 

plug

 

the

 

wires,

 

please

 

insert

 

the

 

plug

 

to

 

the

 

bottom

 

so

 

it

 

is

 

not

 

easily

 

to

 

be

 

unplugged;
4.Make

 

sure

 

that

 

the

 

wires

 

cannot

 

touch

 

the

 

mobile

 

part

 

such

 

like

 

the

 

drum,

 

and

 

also

 

cannot

 

touch the

 

sharp/hard

edged

 

party

 

and

 

high

heat

 

part

 

(motor);

5.Please

 

preserve

 

the

 

screws

 

when

 

you

 

take

 

them

 

down.

 

You

 

will

 

use

 

them

 

when

 

you

 

install

 

the

 

dryer;

6

 

6.ometimes

 

you

 

must

 

operate

 

the

 

dryer

 

when

 

it

 

is

 

electriferous.

 

In

 

this

 

case,

 

you

 

must

 

be

 

careful

 

and pay

 

attention

 

to

 

the

 

electric

 

shock.

Unpacking

 

Ways

 

Of

 

Main

 

Parts

Содержание MDS70-V032_A0431-EU18-P1

Страница 1: ...Service Manual Dryer Model MDS70 V032_A0431 EU18 P1 Note Before service the unit please read this manual first Contact with your service center if meet problem...

Страница 2: ...TROUBLESHOOTING 13 4 1 The Control panel not displayed after selecting the program 4 2 The drum not worked after selecting the program 4 3 Maintenance non heating malfunction 4 4 Drum worked but the e...

Страница 3: ...ecautions that are described on part labels and in the owner s manual 1 2 2 Parts Assembly and wiring Be sure to use insulation material such as tube and tape And be sure to restore all parts and wire...

Страница 4: ...and a person nearby through the misconducted work or of a user by a defect of the product after the work performed by the technician Graphic Symbol Meaning Caution Read the operator s manual before us...

Страница 5: ...lease insert the plug to the bottom so it is not easily to be unplugged 4 Make sure that the wires cannot touch the mobile part such like the drum and also cannot touch the sharp hard edged party and...

Страница 6: ...roof component 3 Take out the roof component 2 Remove the back board component of the case 1 remove the screws fixed back board 2 remove the screws fixed thermostat support component 3 pulled out wir...

Страница 7: ...frame 4 Remove the inner tub assey 1 Remove the reinforced plate 2 take out the belt from the motor shaft 3 removed the screws which is fixed drum kit and the automatic thermostat 4 pull out the termi...

Страница 8: ...the control pannel PCB board and buttons etc 6 Remove the wiring harness including the thermostat 1 remove all the line firm fixed wires 2 pull out the terminals connected the wires with the motor and...

Страница 9: ...the front plate assembly 7 1 remove the door switch plate 7 2 Remove the support components of the drum 7 3 Remove the door gasket and front plate 8 Remove the side plates and base assembly 1 remove t...

Страница 10: ...Pictures 8 2 Remove the impeller 8 3 Remove the fixd block of the motor 8 4 Remove the fixd stator of the motor 8 5 Remove the tight spring 8 6 Take out the motor components 8 7 Remove the capacitanc...

Страница 11: ...disassembling machine Pictures 8 8 Remove the motor bracket Bottom plate and the air duct P1 Motor P2 Door switch P3 Heating pipe P4 Temperature sensor P5 Power cord 2 Unpacking Ways Of Main Parts P1...

Страница 12: ...12 3 Malfunctions Codes And Explanations...

Страница 13: ...e axes is break off or not Change the axes Whether the door is closed well or not lose the door or change the door lock whether the motor wrecked 4 2 The drum not worked after selecting the program NO...

Страница 14: ...f clothes is no more Whether the filter lint 4 3 Maintenance non heating malfunction Whether to set up non heating NO Whether the connect of heater thermostat and PCB panel is well or not NO YES YES N...

Страница 15: ...ES YES YES YES connect to Tub wrap and lifter is loose cause the Screw and the Side plates NO Whether the Underprop wheel NO Whether the Tub shaft is break off NO Whether the Pulley Spring is invalida...

Страница 16: ...O Whether the motor blocked NO Whether the belt sliding or wear leading to rubber odor NO Whether other electrical components broken down YES YES YES YES Clean heater Solve the motor blocked if the mo...

Страница 17: ...a multimeter to test the connection at both ends are each turned on Conducting OK the replacement is not turned on 4 Temperature level Sensor Measured across the resistor with a multimeter the resista...

Страница 18: ...18 Number Tools Suitable kit 1 Sleeve 13 and spanner Drum tub assembly Capacitance 2 Sleeve 14 and pliers Impeller 3 Other tools screwdriver pliers and so on Common service tools 13 14 5 Service Tools...

Страница 19: ...endix 19 Machine function description program description the whole detailed parameter table fault codes etc Please refer to the instructions Note The schedule for the reference value MDS70 V032_A0 31...

Страница 20: ...20 The end...

Отзывы: