Before
repairing,
use
multimeter to
judge
circuit
stand
of
fail
.
5
Check
Point
Of
Circuit
17
No
Parts
parameter
1
Motor
Assembly
Measured
with
a
multimeter primary
and
secondary
windings
of
the
motor.
Main
winding
(white
‐
blue)
30.0
×
(1
±
10%)
Ω
(20
℃
)
Secondary
winding
(white
‐
red)
30.0
×
(1
±
10%)
Ω
(20
℃
)
2
Capacitor
Test
capacitance
value
should
be
9
±
5%uF
3
Thermostat
With
a
multimeter to
test
the
connection
at
both
ends
are
each
turned
on.
Conducting
OK,
the
replacement
is
not
turned
on.
4
Temperature
level
Sensor
Measured
across
the
resistor
with
a
multimeter,
the
resistance
line
with
RT
table.
According
to
the
prevailing
ambient
temperature
determination,
error
±
3
℃
.
5
℃
:
25K
Ω
10
℃
:
20K
Ω
15
℃
:
15.5K
Ω
20
℃
:
1
2.5K
Ω
25
℃
:
10K
Ω
30
℃
:
8K
Ω
35
℃
:
6.5K
Ω
5
Electric
filter
With
a
multimeter to
test
the
connection
at
both
ends
of
the
N
and
L
are
each
turned
on.
Conducting
OK,
the
replacement
is
not
turned
on
6
Heater
Test
resistance
value
should
be
29
±
10%
Ω