Oper

ating

Ins

tructions

Wait 3 

m

inutes before resu

m

ing operation

After the unit has stopped, it can not be restarted in the first 3 minutes to protect 
compressor operation. The unit will restart automatically after 3 minutes.

Auto-Restart

If the unit stops unexpectedly due to a power cut, it will restart with the previous 
function setting automatically when the power resumes.

Setting the Ti

m

er ON and Ti

m

er OFF

• 

When the unit is on, first press the Timer button, the Timer OFF indicator light 
illuminates. It indicates the Timer OFF program is initiated. Press it again the Timer 
ON indicator light illuminates.It indicates the Timer ON is initiated.

• 

When the unit is off, first press the Timer button, the Timer ON indicator light 
illuminates. It indicates the Timer ON program is initiated. Press it again the Timer 
OFF indicator light illuminates. It indicates the Timer OFF is initiated.

• 

Press or hold the    and   key buttons to change the Timer by 0.5 hour increments, 
up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down 
the time remaining until start.

• 

The selected time will register in 5 seconds and the system will automatically revert 
back to display the previous humidity setting.

• 

When the Timer ON and Timer OFF times are set, within the same program 
sequence, indicator lights illuminate identifying both ON and OFF times are now 
programmed.

• 

Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will 
cancel the Timer function.

• 

When LED display window displays the code of P2, the Auto Start/Stop function 
will also be cancelled.

Other Features (cont.)

NOTES

•  When first using the dehumidifier, operate the unit continuously 24 hours. 

Make sure the plastic cover on the continuous drain hose outlet install stightly 
properly so there are no leaks.

•  This unit is designed to operate with a working environment between 5°C/41°F 

and 35°C/95°F.

•  Make sure the water bucket is positioned correctly so that the unit can operate 

properly. 

When the water in the bucket reaches to a certain level, please be 

careful to 

m

ove the unit to avoid it spill.

Содержание MDP30SR71

Страница 1: ...fore using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with...

Страница 2: ...this product Contact the authorized service technician for repair or maintenance of this unit The unit is not designed to be used by young children or people with reduced physical sensory or mental c...

Страница 3: ...ug It may cause electric shock Do not allow water to touch into electric parts It may cause failure or electric shock Do not use the socket if it is loose or damaged It may cause fire and electric sho...

Страница 4: ...n to avoid injuries to hand and fingers Clean filter once every two weeks If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower...

Страница 5: ...ng is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your unit must be used in a properly grounded wall receptacle If the wall receptacle y...

Страница 6: ...e models Power cord buckle placed in the water bucket used only when storing the unit Installed as shown below Re ar Front Product overview Accessories NOTE All the pictures in this manual are for ill...

Страница 7: ...540 300 540 300 540 300 Water tank volume L 3 6 6 6 Air flow Hi Med Lo m3 h 234 219 320 280 320 280 320 280 CFM ft3 min 138 129 188 165 188 165 188 165 Noise level Hi Med Lo dB A 54 3 48 53 5 53 5 Co...

Страница 8: ...ght Clean filter indicator light LED Display On Off Full Auto defrost FILTER Button This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illuminate after...

Страница 9: ...r press the button and set a higher value TIMER Set Control Buttons Use the and key buttons to set the Timer ON or Timer OFF from 0 to 24 hours POWER Button Press to turn the dehumidifier on and off L...

Страница 10: ...by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system w...

Страница 11: ...The unit will restart operation when the bucket back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit 3 Pour the water out Fig 5 Fig 6 NOTES When you...

Страница 12: ...e water flow Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Select the desired humidity setting and fan speed on the unit for continuous drainin...

Страница 13: ...lowing things Cleaning the pump filter Remove the bucket from the unit take down the pump and clean the pump filter See Fig 12 Check if the drain hose is clean and free of debris Empty the water of th...

Страница 14: ...esidential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full...

Страница 15: ...sh to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it around i...

Страница 16: ...ifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a water vapor source in the...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: