MCAC-PDSM-2013-04 Midea Precision AC Technical Manual-Down Delivery Series
17
Outdoor coil
No. of rows
\
4
Tube pitch(a)×row pitch(b)
mm
25.4×22
Fin spacing
mm
2.2
Fin type
\
Hydrophilic aluminum fin
Pipe outside dia. and type
mm
Ф
9.52
Inner grooved copper pipe
Coil (W×D)
mm
1,448×1,219.2
Number of circuits
\
12
Indoor air flow
m
3
/h 10,400
Indoor external static pressure
Pa
20
Indoor drain pipe I.D.
mm
Ф
30
Indoor noise level
dB(A)
≤
69
Outdoor noise level
dB(A)
≤
64
Refrigerant
Type \
R410A
Recharged (After installation)
g
13,500
Control
\
Thermal expansion valve
Maximum refrigeration pipe pressure
MPa
4.4
Refrigerant
pipe
Max. pipe length
m
60
Max. difference in level (O.U. up)
m
20
Max. difference in level (O.U.
down)
m 5
Connection
wire
Indoor power wire
mm
2
3×10.0mm
2
(
A,B,C
)
+2×6.0mm
2
(
N,GND
)
Outdoor power wire
mm
2
4×1.0mm
2
Signal wire
mm
2
4×1.0mm
2
Filter \
G4
Indoor unit
Net dimension (W×H×D)
mm
1,400×1,971×870
Net weight
kg
460
Outdoor unit
Net dimension (W×H×D)
mm
1,660×1,290×690(No include supporting bar)
Net weight
kg
150
Notes:
1. The nominal cooling capacity is based on the following conditions. Indoor temperature: 24°CDB, 17°CWB;
Outdoor temperature: 35°CDB, pipe length is 10 meters.
2. The noise is measured in the semi suppression lab.
3. Specifications are subject to change without prior notice for product improvement.
All manuals and user guides at all-guides.com