DM15-01.01.11-01en
Service manual
Multi DC inverter R410A. Outdoor unit
5
3.
Specification
Outdoor Model
M2OD-16HFN1-Q
M2OD-18HFN1-Q
Power supply
V-ph-Hz
220-240V- 50Hz, 1Ph
220-240V- 50Hz, 1Ph
Single Double Single Double
Cooling
Capacity kW
1,47-3,52
4,81 2,05-4,69 5,28
Input
W
/
1480
/
1650
Rated current
A
/
6,5
/
7,55
EER
/
3,24
/
3,2
Heating
Capacity kW
1,76-3,81
4,75 2,35-4,98 5,57
Input
W
/
1230
/
1550
Rated current
A
/
5,4
/
7,1
COP
/
3,87
/
3,6
Max. input consumption
W
2400
2950
Max. input current
A
11
14
Compressor
Model
ASN108D22UEZ
DA130M1C-31FZ
Type
ROTARY
ROTARY
Brand
GMCC
GMCC
Capacity
Btu/h
11072
13443
Input
W
827
1005
Rated current(RLA)
A
5.85
3.95
Locked rotor Amp(LRA)
A
---
----
Thermal protector position
---
----
Capacitor
μ
F ---
INTERNAL
Refrigerant oil
ml
ESTER OIL VG74 370
ESTER OIL VG74/480
Outdoor fan
motor
Model
WZDK40-38G-W-1
WZDK40-38G-W-1
Qty
1
1
Output W
40(Output)
40(Output)
Capacitor
μ
F
- -
- -
Speed(Hi/Med/Lo) r/min
800 800
Outdoor coil
Number of rows
2
2
Tube pitch(a)* row pitch(b)
mm
25.4x22
25.4x22
Fin spacing
mm
1.4
1.4
Fin type
Hydrophilic aluminium
Hydrophilic aluminium
Tube outside dia.and type
mm
Φ
9.52,innergroove tube
Φ
9.52,innergroove tube
Coil length * height * width
mm
865x508x44
865x508x44
Number of circuits
4
4
Outdoor air flow
m3/h
2100
2100
Outdoor sound pressure level
dB(A)
56
56
Outdoor sound power level
dB(A)
65
65
Throttle type
CaEXV
CaEXV
Outdoor unit
Dimension(WxDxH) mm
810x310x558
810x310x558
Packing(WxDxH) mm
930x400x615
930x400x615
Net/Gross weight
kg
34.5/37.5
36.5/39.5
Refrigerant
Type
R410A
R410A
GWP
2088
2088
Charged quantity
Kg
1.7
2.0
Design pressure
MPa 4.2/1.5
4.2/1.5
Refrigerant
piping
Liquid side/ Gas side
mm(inch) 2 x
Φ
6.35/
Φ
9.52(1/4"/3/8") 2
x
Φ
6.35/
Φ
9.52(1/4"/3/8")
Max. length for all rooms
m
30
30
Max. length for one indoor unit
m
20
20