background image

Midea R410A Domestic Pools & Spas HPWH 50Hz Technical Manual                    MCAC-HTSM-201409 

45 

 

7. Resistance characteristic of temperature sensor 

  Resistance characteristic of ambient Temp., pipe Temp. and suction Temp. sensor. 

Temp. 

(°C) 

Resistance 

value (kΩ) 

Temp. 

(°C) 

Resistance 

value (kΩ) 

Temp. 

(°C) 

Resistance 

value (kΩ) 

Temp. 

(°C) 

Resistance 

value (kΩ) 

-20 

115.266 

20 

12.6431 

60 

2.35774 

100 

0.62973 

-19 

108.146 

21 

12.0561 

61 

2.27249 

101 

0.61148 

-18 

101.517 

22 

11.5 

62 

2.19073 

102 

0.59386 

-17 

96.3423 

23 

10.9731 

63 

2.11241 

103 

0.57683 

-16 

89.5865 

24 

10.4736 

64 

2.03732 

104 

0.56038 

-15 

84.219 

25 

10 

65 

1.96532 

105 

0.54448 

-14 

79.311 

26 

9.55074 

66 

1.89627 

106 

0.52912 

-13 

74.536 

27 

9.12445 

67 

1.83003 

107 

0.51426 

-12 

70.1698 

28 

8.71983 

68 

1.76647 

108 

0.49989 

-11 

66.0898 

29 

8.33566 

69 

1.70547 

109 

0.486 

-10 

62.2756 

30 

7.97078 

70 

1.64691 

110 

0.47256 

-9 

58.7079 

31 

7.62411 

71 

1.59068 

111 

0.45957 

-8 

56.3694 

32 

7.29464 

72 

1.53668 

112 

0.44699 

-7 

52.2438 

33 

6.98142 

73 

1.48481 

113 

0.43482 

-6 

49.3161 

34 

6.68355 

74 

1.43498 

114 

0.42304 

-5 

46.5725 

35 

6.40021 

75 

1.38703 

115 

0.41164 

-4 

44 

36 

6.13059 

76 

1.34105 

116 

0.4006 

-3 

41.5878 

37 

5.87359 

77 

1.29078 

117 

0.38991 

-2 

39.8239 

38 

5.62961 

78 

1.25423 

118 

0.37956 

-1 

37.1988 

39 

5.39689 

79 

1.2133 

119 

0.36954 

35.2024 

40 

5.17519 

80 

1.17393 

120 

0.35982 

33.3269 

41 

4.96392 

81 

1.13604 

121 

0.35042 

31.5635 

42 

4.76253 

82 

1.09958 

122 

0.3413 

29.9058 

43 

4.5705 

83 

1.06448 

123 

0.33246 

28.3459 

44 

4.38736 

84 

1.03069 

124 

0.3239 

26.8778 

45 

4.21263 

85 

0.99815 

125 

0.31559 

25.4954 

46 

4.04589 

86 

0.96681 

126 

0.30754 

24.1932 

47 

3.88673 

87 

0.93662 

127 

0.29974 

22.5662 

48 

3.73476 

88 

0.90753 

128 

0.29216 

21.8094 

49 

3.58962 

89 

0.8795 

129 

0.28482 

10 

20.7184 

50 

3.45097 

90 

0.85248 

130 

0.2777 

11 

19.6891 

51 

3.31847 

91 

0.82643 

131 

0.27078 

12 

18.7177 

52 

3.19183 

92 

0.80132 

132 

0.26408 

13 

17.8005 

53 

3.07075 

93 

0.77709 

133 

0.25757 

14 

16.9341 

54 

2.95896 

94 

0.75373 

134 

0.25125 

15 

16.1156 

55 

2.84421 

95 

0.73119 

135 

0.24512 

16 

15.3418 

56 

2.73823 

96 

0.70944 

136 

0.23916 

17 

14.6181 

57 

2.63682 

97 

0.68844 

137 

0.23338 

18 

13.918 

58 

2.53973 

98 

0.66818 

138 

0.22776 

19 

13.2631 

59 

2.44677 

99 

0.64862 

139 

0.22231 

Содержание LRSJ-120/NYN1-A1

Страница 1: ...Spas Heat Pump Water Heater 50Hz A1 Series Technical Manual Applicable Model New CE safety directive LRSJ 60 NYN1 A1 LRSJ 80 NYN1 A1 LRSJ 120 NYN1 A1 LRSJ 140 NYN1 A1 Midea reserves the right to disc...

Страница 2: ...MCAC HTSM 201409 Midea R410A Domestic Pools Spas HPWH 50Hz Technical Manual 2 Content Part 1 General information 3 Part 2 Performance 5 Part 3 Installation 25...

Страница 3: ...Midea R410A Domestic Pools Spas HPWH 50Hz Technical Manual MCAC HTSM 201409 3 Part 1 General information 1 Model Names of Units 4 2 External Appearance 4 3 Nomenclature 4...

Страница 4: ...NYN1 A1 220 240V 1Ph 50Hz LRSJ 120 NYN1 A1 220 240V 1Ph 50Hz LRSJ 140 NYN1 A1 220 240V 1Ph 50Hz 2 External Appearance LRSJ 60 NYN1 A1 LRSJ 80 NYN1 A1 LRSJ 120 NYN1 A1 LRSJ 140 NYN1 A1 3 Nomenclature L...

Страница 5: ...Technical Manual MCAC HTSM 201409 5 Part 2 Performance 1 Features 6 2 Specifications 7 3 Dimensions Unit mm 10 4 Service Space 11 5 Refrigerant circuit 12 6 Wiring Diagrams 13 7 Electric Characteristi...

Страница 6: ...ctly connected with poor Without secondary heat exchanger it is can improve the efficiency of whole system Easy operation and automatic control the system can be controlled simply through the wired co...

Страница 7: ...vel dB A 58 58 Refrigerant Type Discharged R410A 1 00kg R410A 1 25kg Refrigerant control Capillary Capillary Fan Type Axial fan Axial fan Motor model YDK85 6 YDK85 6 Motor brand Welling Welling Quanti...

Страница 8: ...erature 27 C Water flow volume has been defined Model LRSJ 120 NYN1 A1 LRSJ 140 NYN1 A1 Power supply 220 240V 1Ph 50Hz 220 240V 1Ph 50Hz Outlet water temperature Heating mode Default 28 C 20 C 35 C De...

Страница 9: ...V Rated current RLA A 11 40 13 10 Locked rotor Amp LRA A 61 63 Thermal protector Internal Internal Refrigerant oil ml 950 1 100 Water pipe Inlet pipe mm 50 50 Outlet pipe mm 50 50 Water circulation pi...

Страница 10: ...H 50Hz Technical Manual 10 3 Dimensions Unit mm Top view Unit mm Model A B C D E F LRSJ 60 NYN1 A1 610 390 170 1 015 385 705 LRSJ 80 NYN1 A1 610 390 170 1 015 385 705 LRSJ 120 NYN1 A1 590 333 165 1 05...

Страница 11: ...Midea R410A Domestic Pools Spas HPWH 50Hz Technical Manual MCAC HTSM 201409 11 4 Service Space...

Страница 12: ...MCAC HTSM 201409 Midea R410A Domestic Pools Spas HPWH 50Hz Technical Manual 12 5 Refrigerant circuit...

Страница 13: ...Midea R410A Domestic Pools Spas HPWH 50Hz Technical Manual MCAC HTSM 201409 13 6 Wiring Diagrams LRSJ 60 NYN1 A1 LRSJ 80 NYN1 A1...

Страница 14: ...MCAC HTSM 201409 Midea R410A Domestic Pools Spas HPWH 50Hz Technical Manual 14 LRSJ 120 NYN1 A1 LRSJ 140 NYN1 A1...

Страница 15: ...RSJ 140 NYN1 A1 Item Detail N C No need connect Tout Outlet water temperature sensor T3 Heat exchanger temperature sensor T4 Outdoor ambient temperature sensor T6 Inlet water temperature sensor Tp Tem...

Страница 16: ...A TOCA Total Over current Amps A MSC Max Starting Amps A RLA Rated Locked Amps A OFM Outdoor Fan Motor kW Fan Motor Rated Output kW FLA Full Load Amps A Model LRSJ 120 NYN1 A1 LRSJ 140 NYN1 A1 Outdoor...

Страница 17: ...201409 17 8 Capacity Curve LRSJ 60 NYN1 A1 Heating mode Test condition inlet water temperature of the units is 27 C outlet water temperature is 29 C Relation between heating capacity and outdoor ambi...

Страница 18: ...s HPWH 50Hz Technical Manual 18 Cooling mode Test condition inlet water temperature of the units is 27 C water volume is 2 6m3 h Relation between cooling capacity and outdoor ambient temperature Relat...

Страница 19: ...anual MCAC HTSM 201409 19 LRSJ 80 NYN1 A1 Test condition inlet water temperature of the units is 27 C outlet water temperature is 29 C Relation between heating capacity and outdoor ambient temperature...

Страница 20: ...s HPWH 50Hz Technical Manual 20 Cooling mode Test condition inlet water temperature of the units is 27 C water volume is 3 5m3 h Relation between cooling capacity and outdoor ambient temperature Relat...

Страница 21: ...nual MCAC HTSM 201409 21 LRSJ 120 NYN1 A1 Test condition inlet water temperature of the units is 27 C outlet water temperature is 29 C Relation between heating capacity and outdoor ambient temperature...

Страница 22: ...s HPWH 50Hz Technical Manual 22 Cooling mode Test condition inlet water temperature of the units is 27 C water volume is 5 0m3 h Relation between cooling capacity and outdoor ambient temperature Relat...

Страница 23: ...nual MCAC HTSM 201409 23 LRSJ 140 NYN1 A1 Test condition inlet water temperature of the units is 27 C outlet water temperature is 29 C Relation between heating capacity and outdoor ambient temperature...

Страница 24: ...ter temperature of the units is 27 C water volume is 5 8m3 h Relation between cooling capacity and outdoor ambient temperature Relation between EER and outdoor ambient temperature 9 Accessories Name Q...

Страница 25: ...l Manual MCAC HTSM 201409 25 Part 3 Installation 1 Safety information 26 2 Unit Installation 28 3 Functions maintenance 34 4 Controller operation 37 5 Trial run 40 6 Fault analysis and solutions 41 7...

Страница 26: ...epairing and maintaining the unit Improper installation may result in water leakage electric shock or fire Electric connection work should obey the instructions of local power company local electric u...

Страница 27: ...dual operating current not exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with the wire rules Arrange the drain pipe to ensure smooth draining Improper drainag...

Страница 28: ...t affect neighbors Installing the unit in any of the following places may lead to faults of the unit If that is inevitable please consult the factory The site contains mineral oils such as cutting lub...

Страница 29: ...lling site please confirm the main unit is placed in horizontal Choose the appliance installation site according to the following criteria the clearance around the appliance must be respected to avoid...

Страница 30: ...mpliance with applicable standards Keep the unit out of reach of children 2 4 Distance of unit ground screws Unit mm Model A B C D E LRSJ 60 NYN1 A1 610 390 170 1 015 385 LRSJ 80 NYN1 A1 610 390 170 1...

Страница 31: ...insulation materials should be employed to seal up inlet and outlet water pipes Before operation please confirm that the specifications of connective pipes are correct and thermal insulation layer has...

Страница 32: ...e a specialized power supply which voltage must in compliance with the rated voltage Power supply circuit of the unit with earthing wires that must be reliably connected Wiring must be performed by pr...

Страница 33: ...an 2 If the continuous wire length valve larger than the one of the table please choose its size in compliance with the relevant rules Model Power supply Min wire size mm 2 Metal pipe synthetic resin...

Страница 34: ...ections of low voltage electric signal wire with heavy electric wire otherwise some of electric control elements will burned out The following diagram is electric wiring diagram for the units 3 Functi...

Страница 35: ...e When protection device does operate though the unit stops the operating indicator of wired controller still will be blinking When protection device operates nixie indicator will display malfunction...

Страница 36: ...has serviced for a period of time Generally once a month it is necessary to press the test button at close circuit to check whether the performance of RCCB is work normally Every time press this butt...

Страница 37: ...heating capacity The heating process is a heat pump mode that it absorbs heat from outdoor and release to water Once the outdoor temperature decreases the heating capacity will also decrease simultane...

Страница 38: ...n or protection time 6 ALARM indicator It will flash at the malfunction or protection time 4 2 Names of keys on the controller 7 MODE key Used to set different modes 8 UP key Used to add time or tempe...

Страница 39: ...hen the swimming temperature is high in summer Heat mode The unit heats swimming pool water by compressor driving according to heat pump principle Used when the ambient temperature is low Pump mode Th...

Страница 40: ...compulsory operation It is very dangerous if the protection device is not active Trial run is stop performed only after all installation is finished Confirm the following insure before operation The w...

Страница 41: ...f hiss every now and then At the beginning and the end of the defrost process sound is given out in motor valve During the process or just after having stopped sound like water flow occur which will b...

Страница 42: ...Remarks 1st Normal display Inlet water temperature Value of T6 2nd Mode code 0 6KW 1 8KW 2 11 7KW 3 13 6KW 3rd Operate mode 1 Water cooling 16 Water heating 4 Pump 8 standby 4th Fan speed 0 Off 1 Low...

Страница 43: ...ged Check whether the T6 temperature sensor is correctly connected to the motherboard Check whether the signal of T6 sensor is in strong electromagnetic interference E5 Evaporator pipe temperature sen...

Страница 44: ...load protection Check whether the dial code S2 is correct Check whether the voltage supplied is in the accepted voltage range Check whether compressor is damaged Check whether the refrigerant pipes i...

Страница 45: ...34 6 68355 74 1 43498 114 0 42304 5 46 5725 35 6 40021 75 1 38703 115 0 41164 4 44 36 6 13059 76 1 34105 116 0 4006 3 41 5878 37 5 87359 77 1 29078 117 0 38991 2 39 8239 38 5 62961 78 1 25423 118 0 3...

Страница 46: ...2 2 63 7 261 4 33 38 89 73 8 643 113 2 559 6 247 8 34 37 3 74 8 358 114 2 489 5 234 9 35 35 78 75 8 084 115 2 422 4 222 8 36 34 32 76 7 82 116 2 357 3 211 4 37 32 94 77 7 566 117 2 294 2 200 7 38 31 6...

Отзывы: