MCAC-HTSM-201409 Midea R410A Domestic Pools & Spas HPWH 50Hz Technical Manual
42
In case of following malfunction, please cut off the manual power switch, and repair it.
The fuse was burnt out frequently or the earth leakage protective device was broken up
frequently.
Only the red indication lamp flashes.
Detail spot check display contents as following:
Sequence
System operation parameters
Remarks
1st
Normal display (Inlet water
temperature)
Value of T6
2nd
Mode code
0: 6KW; 1: 8KW; 2: 11.7KW; 3:
13.6KW
3rd
Operate mode
1 Water cooling; 16 Water heating
;
4
Pump; 8 standby
4th
Fan speed
0: Off 1: Low 2:High
5th
Ambient temperature
Value of T4
6th
Compressor discharge temperature
Value of Tp
7th
Pipe temperature
Value of T3
8th
Inlet water temperature
Value of T6
9th
Outlet water temperature
Value of Tout
10th
Compressor current
Value of current
11st
Setting water temperature
Value of Ts
12nd
The last error code or protection code
Display the latest error code or
protection code