background image

4.  Installation of the Gas Pipe
a.  Select  specified  rubber  hoses  or  qualified  rigid  pipes 

and gas pressure relief valve. (GB10546 and GB12244 

compliant).

b.  Select  the  dimensions  of  the  pipe  according  to  the 

Connector Specifications in the Technical Performance 

Parameter List.

c.  The length of the rubber hoses cannot be greater than 

2m when the liquefied gas is used.

d.  Install a rubber seal ring between the gas intake of the 

water heater and the hose connector. The rubber hose 

must  be  connected  to  the  red  line  of  the  hose 

connector and must be fastened with a clamp.

e.  Connect with a rigid pipe when the pipeline gas is used. 

Install  a  gas  valve,  the  passage  of  which  has  an 

effective  area  greater  than  45mm2,  that  is,  the  inner 

diameter is more than Φ7.5mm.

f.  After  the  installation,  use  the  soapy  water  to  check 

whether there is a gas leak.

Using Methods

Preparations before Ignition

1.  During  the  initial  use  of  the  water  heater,  open  the 

battery case and put in two D batteries according to the 

correct battery polarity.

2.  Switch the water inlet valve to the maximum and switch 

on the hot water outlet valve to check whether there is 

water flowing out.

3.  Then,  switch  off  the  hot  water  outlet  valve  and  fully 

open the main gas valve.

Ignition/Operation

1.  Ignition: After the preparation work, open the hot water 

outlet valve, and the water heater will make a “poop” 

sound, and then the hot water will immediately flow out. 

If  the  water  heater  cannot  be  ignited  for  one  time, 

switch off the hot water outlet valve at once and restart 

it after 10-20 seconds. (Note: For some models, adjust 

the  Hot/Cold  Water  switch  to  the  hot  water  mode 

before ignition.)

2.  Outlet  water  temperature  regulation:  Switch  the 

firepower regulation knob to “Max” or switch the water 

temperature regulation knob to “High”, the outlet water 

temperature  can  be  increased;  switch  the  firepower 

regulation  knob  to  “Min”  or  switch  the  water 

temperature regulation knob to “Low”, the outlet water 

temperature can be decreased.

3.  When  the  firepower  regulation  knob  is  switched  to 

“Min”  and  the  water  temperature  regulation  knob  is 

switched to “Low”, if the outlet temperature is still high, 

then  switch  the  season  change  knob  to  the 

“Summer-Autumn” position. On the contrary, when the 

firepower regulation knob is switched to “Max” and the 

water  temperature  regulation  knob  is  switched  to 

“High”, if the outlet temperature is still low, then switch 

the  season  change  knob  to  the  “Winter-Spring” 

position. 

Water Heater

Rubber Seal

Rubber Seal

Hose Connector

Clamp

On

On

On

On

On

Install batteries in 

a correct way.

Open the water inlet valve. Open 

the hot water outlet valve to check 

whether there is water flowing out. 

Switch off the hot water outlet 

valve and switch on the gas valve.

Hot/Cold Water Switch 

Mode (for some models)

Open the hot water outlet valve and the 

water heater will ignite automatically.

When the firepower is at “Max” mode, 

the  water  temperature  is  at  “High” 

mode, and the season change knob is 

switched to the “Winter-Spring” mode, 

the  outlet  water  temperature  is  the 

highest.

When the firepower is at “Min” mode, 

the  water  temperature  is  at  “Low” 

mode, and the season change knob is 

switched  to  the  “Summer-Autumn” 

mode, the outlet water temperature is 

the lowest.

Hot/Cold Water Switch

Off

Off

High

low

big

big

Small

Small

low

High

Summer-Autumn

Summer-Autumn

Winter-Spring

Winter-Spring

Note:  Gas Inlet----Gas Supply Pipe

 

Hot Water Outlet----Outlet Pipe

 

Hot Water Outlet----Outlet Pipe

Note: Place  a  rubber  seal  ring 

when using metal hoses.

The connectors at the bottom would 

be  in  a  different  order  for  different 

models. Connect them according to 

the instructions on the water heater.

Red Line

Gas Inlet 

Gas Supply Pipe

Inlet Pipe 

Outlet Pipe

Hot Water Outlet

Rubber 

Hose

Automatic 

ignition

Cold Water 

Inlet

Water

 Valve 

Water

 Flow

 Out 

Gas

 Valve 

Содержание JSQ Series

Страница 1: ...er The diagram above is just for reference Please take the appearance of the actual product as the standard Please read the instruction manual carefully before installing and operating this water heat...

Страница 2: ...8 Water gas Linkage Control The water heater will automatically stop combustion and shut down when the supply of tap water is suspended or the water valve is shut off 9 Over pressure Protection When...

Страница 3: ...le Water Pressure Rated Yield Capacity of the Hot Water Temperature Rise 25k Gas Inlet Cold Water Inlet Hot Water Inlet Dimensions L W H Net Weight Diameter of the Smoke Vent JSQ Series Liquefied Petr...

Страница 4: ...A smoke exhaust pipe must be also installed 5 Install the water heater in a place where the line of sight and the viewport are at the same level that is 1 55 1 65m above the ground and where the water...

Страница 5: ...be greater than 20mm when the flue pipe passes through the wall made up of combustible materials f Try not to hide the flue pipe inside the ceiling Wrap up the flue pipe with heat insulating materials...

Страница 6: ...let water temperature can be increased switch the firepower regulation knob to Min or switch the water temperature regulation knob to Low the outlet water temperature can be decreased 3 When the firep...

Страница 7: ...t ignite the water heater or switch on any electrical appliance Open all doors and windows to automatically vent the gas to the outdoors Stop using the water heater and contact the maintenance departm...

Страница 8: ...by the water heater is not potable just used as non potable water 2 Freezing prevention When the water heater is used in cold areas where the ambient temperature is below 0 C the water stored in the...

Страница 9: ...o yellow and there arises black smoke contact the technician in time for cleaning 3 Frequently use soft cleaning cloth to wipe the hull of the water heater with clean water or neutral detergent rather...

Страница 10: ...der the following circumstances The water heater cannot ignite No hot water flows out The water is not hot enough The water is too high The main gas valve is not opened There is air in the gas pipe Th...

Страница 11: ...ance of the technician in our special service department c No valid proof of purchase d Valid proof of purchase altered e The model number and product code registered in the installation card in disag...

Страница 12: ...lation personnel take the gas leak test with the soapy water Do the installation personnel inform you to take the gas leak test Do the installation personnel demonstrate to you how to change batteries...

Страница 13: ...l take the gas leak test with the soapy water Do the installation personnel inform you to take the gas leak test Do the installation personnel demonstrate to you how to change batteries Do the install...

Отзывы: