Service Manual_2020-V3.0
46
10. Compressor
10.1 Compressor on and off control specifications
1.1 When one of the following conditions is met, the compressor stops:
1) Measured temperature in
all
chambers
≤ Shutdown temperature of
all
chamber
2) Enter defrosting cycle
3) The compressor runs continuously for more than 3 hours, will stop at least 10 minutes
1.2 When compressor shutdown time has been more than 5 min, one of the following conditions is
met, the compressor starts up:
1) Measured temperature in refrigerator chamber
≥ Start up temperature of refrigerator
2) Measured temperature in freezer chamber
≥ Start up temperature of freezer
3) Refrigerator is set to forced cooling mode or
super
cooling or
super
freeze mode
★
When 1.1 and 1.2 are not satisfied, the compressor maintains the original state
Содержание HD-676REWN
Страница 5: ...Service Manual_2020 V3 0 5 1 Significant update notes None...
Страница 17: ...Service Manual_2020 V3 0 17 5 2 Circuit diagram F Freezer R Refrigerator AMB Ambient temperature...
Страница 24: ...Service Manual_2020 V3 0 24 Light of the freezing...
Страница 47: ...Service Manual_2020 V3 0 47 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Страница 48: ...Service Manual_2020 V3 0 48...
Страница 49: ...Service Manual_2020 V3 0 49 11 2 No working of compressor...
Страница 50: ...Service Manual_2020 V3 0 50 11 3 Inside frosting no defrosting...
Страница 51: ...Service Manual_2020 V3 0 51 11 4 Inside frosting no defrosting Maintenance guidelines...
Страница 52: ...Service Manual_2020 V3 0 52 11 5 Light is not on...
Страница 53: ...Service Manual_2020 V3 0 53 11 6 Fan failure 11 7 Defective defrost circuit...
Страница 54: ...Service Manual_2020 V3 0 54 11 8 Noise 11 9 Air duct not operated...
Страница 55: ...Service Manual_2020 V3 0 55 11 10 Ice makernot make ice Option...