Model

ARS2304A

ARS2604A

Capacity

23.2 cu ft

25.9 cu ft

Electrical requirements
separate circuit

115 VAC  60 Hz
15 amps

115 VAC  60 Hz
15 amps

Refrigerant type

R134a

R134a

Width
without side extrusions

35.75

35.75

Depth
without handle
includes door extrusions

29.75

32.5

Height
including top hinge cap

68.5

68.5

No Load Performance Controls in Normal Position

Kw/24 hr ±0.4

Percent Run Time

±10%

Cycles/24 hr

±25%

Refrigerator

Compartment

Average Food

Temperature ±3°F

Freezer

Compartment

Average Food

Temperature ±3°F

Ambient °F

65°

90°

110°

65°

90°

110°

65°

90°

110°

65°

90°

110°

65°

90°

110°

ARS2304A

1.4

2

4

35

55

100

32

28

0

36

39

38

2

2

1

ARS2604A

1.4

2

4

34

60

100

31

23

0

36

37

35

2

1

-3

Temperature Relationship Test Chart

T-1 Outlet

±3°F

T-2 Inlet

±3°F

T-3 Suction Line

±7°F

Average Total

Wattage ±10%

Suction

Pressure ±2

PSIG

Head Pressure

±5 PSIG

Ambient °F

65°

90°

65°

90°

65°

90°

65°

90°

65°

90°

65°

90°

ARS2304A

-15

-17

-18

-16

78

100

153

163

0

1

85

124

ARS2604A

-14

-17

-20

-16

73

98

156

165

0

1

82

131

!

CAUTION

All safety information must be followed as provided in Service Manual RS1300004.

!

WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

Содержание ARS2304A PARS2304AB0

Страница 1: ... Percent Run Time 10 Cycles 24 hr 25 Refrigerator Compartment Average Food Temperature 3 F Freezer Compartment Average Food Temperature 3 F Ambient F 65 90 110 65 90 110 65 90 110 65 90 110 65 90 110 ARS2304A 1 4 2 4 35 55 100 32 28 0 36 39 38 2 2 1 ARS2604A 1 4 2 4 34 60 100 31 23 0 36 37 35 2 1 3 Temperature Relationship Test Chart T 1 Outlet 3 F T 2 Inlet 3 F T 3 Suction Line 7 F Average Total ...

Страница 2: ...ttings 1 4 7 Closing temperatures 47 F 40 F 30 F R0161092 Control freezer temperature Settings 1 in 1 out 4 in 4 out 7 in 7 out Temperatures 21 0 F 4 5 F 13 3 F 5 9 F 9 8 F 11 0 F B2150504 Drier Drier must be changed every time the system is opened for testing or compressor replacement Desiccant 20 8 x 12 4AXH 7 M S Grams 12049801 Heater evaporator Volt Wattage Resistance 115 VAC 450 5 watts 29 5 ...

Страница 3: ...econds Short time trip amps 77 F 25 C 115 VAC 3 51 amps 142 F 61 C 9 257 F 125 C 5 10 seconds 5 14 amps 10097202 Relay ptc Resistance With power off check Across terminals 2 3 Shorted Open 4 6 ohms 0 ohms Very high or infinite ohms 12466102 Switch refrigerator freezer light Type Volt Current DPST NC 125 VAC 5 0 amps 12017823 Thermostat Volt Watt Current Resistance across terminals Above 48 5 F Bel...

Страница 4: ...tor and freezer door Foamed as an assembly during manufacturing Inner door liner and outer door pan are not replaceable If damaged entire door must be replaced WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed...

Страница 5: ...2604A PARS2604AW0 WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization ...

Страница 6: ...604A PARS2604AW0 WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization ...