Service Manual_2020-V1.0
72
10. Compressor
10.1 Compressor on and off control specifications
1.1 When one of the following conditions is met, the compressor stops:
1) Measured temperature in
refrigerator
room ≤ Shutdown temperature of
refrigerator
room and
measured temperature in freezer room ≤ Shutdown temperature of freezer room, and
measured temperature in ice maker room≤ Shutdown temperature of ice maker room;
2) Enter defrosting cycle;
3) If the compressor runs continuously for more than 15 hours, it will stop at least 5 minutes.
1.2 When compressor shutdown time is more than 5 min, the compressor will start up once one of
the following conditions is met:
1) Measured temperature in refrigerator room ≥ Start up temperature of refrigerator;
2) Measured temperature in freezer room ≥ Start up temperature of freezer;
3) Measured temperature in ice maker room ≥ Start up temperature of ice maker room;
4) Refrigerator is set to forced cooling mode or super cooling.
★
When 1.1 and 1.2 are not satisfied, the compressor will maintain the original state.
10.2 Inverter board fault analysis
(
Option
)
Running status of LED
Fault Type
Troubleshooting and Solutions
The light stays on
normal work
Blink once: light 1 second,
extinguish 1 second
Standby
Step 1: Test the voltage between the two pins of
communication, it should be
>
1V, the voltage
between pins of L and N, it should be 110V
Step 2: If the test result of step 1 is fine, replace a
new inverter board
Step 3: If there is no voltage output between the
pins of L and N, please check the power supply
and power cable
Step 4: If there is no voltage output between the
two pins of communication, please check the
connection and connection wire between main
PCB and inverter
Blink once: light 0.5 second,
extinguish 1.5 second
Overcurrent
protection
Step 1: Measure whether the U-V-W resistance of
compressor is same
Step 2: If ok, replace a new inverter board
Step 3: If the fault still occurs, replace a new
compressor
Blink twice: light 0.5 second,
extinguish 0.5 second, interval
time(extinguish) is 1.5 second
Overvoltage
Measure the voltage between L and N
1
)
If it is more than 138V, replace a new inverter
board
2
)
If more than 138V, please check the power
Содержание French-Door Series
Страница 5: ...Service Manual_2020 V1 0 5 1 Significant update notes None ...
Страница 22: ...Service Manual_2020 V1 0 22 5 5 Inverter board terminal connection diagram Option ...
Страница 74: ...Service Manual_2020 V1 0 74 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic ...
Страница 75: ...Service Manual_2020 V1 0 75 ...
Страница 76: ...Service Manual_2020 V1 0 76 11 2 No working of compressor ...
Страница 77: ...Service Manual_2020 V1 0 77 11 3 Inside frosting no defrosting ...
Страница 78: ...Service Manual_2020 V1 0 78 11 4 Inside frosting no defrosting Maintenance guidelines ...
Страница 79: ...Service Manual_2020 V1 0 79 11 5 Light is not on ...
Страница 80: ...Service Manual_2020 V1 0 80 11 6 Fan failure 11 7 Defective defrost circuit ...
Страница 81: ...Service Manual_2020 V1 0 81 11 8 Noise 11 9 Air duct not operated ...
Страница 82: ...Service Manual_2020 V1 0 82 11 10 Ice makernot make ice Option ...
Страница 83: ...Service Manual_2020 V1 0 83 11 11 No ice or crushed ice falling off the distributor Option ...