10

Be

 

sure

 

to

 

use the same insulating materials when you buy the brass pipe. (More than 

9mm thick) 

Use the market brass pipe.

 Chart 15

 Chart 16

 Chart 17

Use frozen oil

Bend the pipe with thumb 

Min-radius 100mm

Make the ends 
straight 

2. Locate The Pipe
1) Drill a hole in the wall (suitable just for the size of the wall conduit, 90mm in general), then
     set on the fittings such as the wall conduit and its cover.
2) Bind the connecting pipe and the cables together tightly with binding tapes. Do not let air
    in, which will cause water leakage by condensation.
3) Pass the bound connecting pipe through the wall conduit from outside.  Be careful of the
    pipe allocation to do no damage to the tubing.
3. Connect the pipes.
4. Then, open the stem of stop valves of the outdoor unit to make the refrigerant pipe conne-
    cting the indoor unit with the outdoor unit fluently flow.
5. Be sure of no leakage by checking it with leak detector or soap  water.
6. Cover the joint of the connecting pipe to the indoor unit with the soundproof/insulating 
    sheath  (fittings),  and bind it well with the tapes to prevent leakage.

Daub the surfaces of  the flare pipe and the joint nuts with frozen oil, and wrench it for 3~4
rounds with hands before fasten the flare nuts. (Refer to chart 14) 
Be sure to use two wrenches simultaneously when you connect or disconnect the pipes.

Cautions

2) The stop valve of the outdoor unit should be closed absolutely (as original state). Every
    time you connect it, first loosen the nuts at the part of stop valve, then connect the flare
    pipe immediately (in 5 minutes). If  the nuts have been loosened for a long time, dusts
    and other impurities may enter the pipe system and may cause malfunction later. So 
    please expel the air out of the pipe with refrigerant  before connection.

o

The bending angle should not exceed 90 C
Bending position is preferably in the bendable pipe. The larger the better it is .
Do not bend the pipe more than three times.
 

3) Expel the air (refer to the 

Expel The Air ) after connecting the refrigerant pipe with the

    indoor unit and the outdoor unit.
    Then fasten the nuts at the repair-points.
 

Notices For Benable pipe.                         

Cut out a desired concave at the bending part of the insulating pipe.
Then expose the pipe(cover it with tapes after bending).
To prevent collapsing of deforming, please bend the pipe at its biggest radius.
Use bender to get a small radius pipes.

Bend the connecting pipe of small wall thickness.

Содержание CEILING TYPE

Страница 1: ...TALLATION MANUAL For correct installation read this manual before starting installation This manual may be subject to change without notice for purpose of improvement CEILING AND FLOOR TYPE AIR CONDITIONER ...

Страница 2: ...TENT Installation precaution 1 Installation place Indoor unit installation 4 Outdoor unit installation 8 Install the connecting pipe 9 Connect the drain pipe 1 Accessories 3 11 Wiring 12 Test operation 16 ...

Страница 3: ...ers how to correctly use and maintain the air condi tioner as well as remind users to carefully read and keep both Installation Manual and Owner s Manual well INSTALLATION PRECAUTION The Indoor Unit The Outdoor Unit INSTALLATION PLACE Location in the following places may cause malfunction of the machine If unavoidable please consult your local dealer a There exists petrolatum b There is salty air ...

Страница 4: ...irective 89 336 EEC For to prevent flicker impressions during the start of the compressor technical process following installation conditions apply 1 The power connection for the air conditioner has to be done at the main power distribution The distribution has to be of a low impedance normally the required impedance reaches a 32A fusing point at 2 No other equipment has to be connected with this ...

Страница 5: ...at least 1m apart from the nearest TV set or stereo equipment It is necessary to prevent image disturbances or noise interferences Do not install the remote controller in a place exposed to direct sunlight or close to a heating source such as a stove Note that the positive and negative poles are in right positions when loading batteries Cautions on remote controller installation 1 1 2 Name of Acce...

Страница 6: ...sult the construction personn els for the specific procedures 1 The size of the ceiling to be handled do keep the ceiling flat Consolidate the roof beam for possible vibration 2 Cut off the roof beam 3 Strengthen the place cut off and consolidate the roof beam Put the square timber traversely over the roof beam then install the hanging screw bolts Refer to Chart 1 Chart 1 Timber over the beam Roof...

Страница 7: ...ng point of refrigerant pipe D gas side D Connecting point of refrigerant pipe E Liquid side Drain point Hook Chart 6 Washer 1 Fix the hook with tapping screw onto the wall Refer to Chart 6 2 Hang the indoor unit on the hook Tapping screw 6mm Hook ...

Страница 8: ...d Screw nut Washer Hanging screw bolt Hanging arm Chart 9 20 25mm Mounting bolt max 40mm 2 Locate the hanging arm on the hanging screw bolt Refer to Chart 9 Prepare the mounting bolts on the unit Refer to Chart 10 Chart 10 8 13mm Hanging arm Grille For models 48000 and 60000 Btu h do not remove the grille ...

Страница 9: ... refrigerant pipe E Liquid side The dimension of the unit E F G Chart 11 3 Hang the unit on the hanging arm by sliding backward Securely tighten the mounting bolts on both sides Refer to Chart 9 H C ATTENTION The figures above are based on model with 18000Btu h as rated capacity which may differ from the unit you purchased 990 660 206 505 506 907 200 203 1280 660 206 795 506 1195 200 203 1670 680 ...

Страница 10: ...Do not lean it more than 45 and do not lay it sidelong OUTDOOR UNIT INSTALLATION Keep this unit away from direct radiation of the sun or other heaters If unavoidable please cover it with a shelter In places near coast or with a high attitude where the wind is strong please install the outdoor unit against the wall to ensure normal performance Use a baffle when necessary In the case of extremely st...

Страница 11: ...ng the time of installation The connecting pipe should not be installed until the indoor and outdoor units have been fixed already Keep the connecting pipe dry and do not let moisture in during installation 1 Connect the indoor unit at first then the outdoor unit Bend the tubing in proper way Don t harm them The Procedure of Connecting Pipes 1 Measure the necessary length of the connecting pipe an...

Страница 12: ... of the flare pipe and the joint nuts with frozen oil and wrench it for 3 4 rounds with hands before fasten the flare nuts Refer to chart 14 Be sure to use two wrenches simultaneously when you connect or disconnect the pipes Cautions 2 The stop valve of the outdoor unit should be closed absolutely as original state Every time you connect it first loosen the nuts at the part of stop valve then conn...

Страница 13: ...1 5m 2m Insulating material Downward declivity lower than 1 100 VP30 Downward declivity lower than 1 100 Put as deep as possible about 10cm Chart 17 Bend S shape 1 Install indoor unit drain pipe The outlet has PTI screw bread Please use sealing materials and pipe sheath fitting when connecting PVC pipes CAUTIONS 2 Drainage test Check whether the drainpipe is unhindered New built house should have ...

Страница 14: ...tioner is 10m long Be sure to prolong it with wiring of the same type and proper length if necessary Generally do not twist two wiring together unless the joint is soldered well and covered with insulator tape 7 Do not turn on the power until you have checked carefully after wiring Attaching wiring The Specification of Power WIRING A 2 mm 2 mm 220 240V 50Hz TYPE POWER GROUND WIRING OUTDOOR UNIT PO...

Страница 15: ... Power wiring indoor Power linking wiring Outdoor Strong elec signal link wiring Weak elec signal link wiring Indoor Unit Outdoor Unit Ground the air conditioner properly in case to affect its anti interference function Chart 19 13 Air Conditioner Link circuit 18000Btu h 1 PHASE CAUTION When wiring pleasechoose the correspondingchart or itmay cause damage ...

Страница 16: ...14 Chat 21 Air Conditioner Link circuit 24000Btu h 1 PHASE Air Conditioner Link circuit Chat 22 36000 60000Btu h 3 PHASE ...

Страница 17: ...irection of the arrow to remove the protection board Notice Do not scratch the surface during operation ATTENTION Chart 23 is based on one type of outdoor units which may look different from your own outdoor unit Chart 23 Protection board Terminator The Outdoor Units 15 ...

Страница 18: ...d The air conditioner is pre heated by turning on the power Set the air conditioner under the mode of COOLING with the remote controller and check the following points per the Owner s Manual If there is any malfunction please resolve it through chapter Troubles And Causes in the Owner s Manual 1 The indoor unit a Whether the switch on the remote controller works well b Whether the buttons on the r...

Страница 19: ...MDV05I 011aW 2200019056 ...

Отзывы: