5. Mounted the valve stem caps and the service port
Use torque wrench to tighten the service port cap to a torque of 18N.m.
Be sure to check for gas leakage.
7. Operation characteristics
Mode
Temperature
Cooling operation
Heating
operation
Drying operation
Room temperature
17
℃
~32
℃
0
℃
~30
℃
10
℃
~32
℃
(<21000Btu/h models)
17
℃
~32
℃
(≥
21000Btu/h models)
Outdoor
temperature
18
℃
~43
℃
(
-5
℃
~43
℃
:For the models with
low temperature cooling system
)
(
21
℃
~52
℃
:For special tropical
models
)
-7
℃
~24
℃
11
℃
~43
℃
(<21000Btu/h models)
18
℃
~43
℃
(
≥
21000Btu/h models)
21
℃
~52
℃
(For special tropical
models)
CAUTION:
1. If air conditioner is used outside of the above conditions, certain safety protection features may
come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the
surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within this operating temperature.
Содержание 9V SERIES
Страница 1: ...9VSAP 1010 A SERVICE MANUAL MIDEA AIRCONDITIONER On Off SPLIT WALL MOUNTED TYPE 9V SERIES 9220 9221...
Страница 13: ...11 4 Refrigerant Cycle Diagram Cooling only Heat pump mode...
Страница 14: ...12 5 Wiring Diagram 5 1 Indoor Unit Cooling only...
Страница 15: ...13 Cooling Heating...
Страница 16: ...14 5 2 Outdoor Unit Smaller than 18K model Cooling only...
Страница 17: ...15 Cooling Heating...
Страница 18: ...16 For 18 K model Cooling only...
Страница 19: ...17 Cooling Heating...