Service Manual_2018-V1.0
34
9.5 Fault code and solutions
Fault code Fault content
Code
visible
Steps for maintenance methods
E1
Temperature
sensor fault in
refrigerating
chamber
Yes
Step 1: Check whether the terminal CN1 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there’re foreign matters on the
terminal. Pull out the refrigerating sensor according to
the method in described in Article 8.4 and then inspect
the sensor against the resistance value table in 10.6.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E2
Temperature
sensor fault in
freezing
chamber
Yes
Step 1: Check whether the terminal CN1 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if therere foreign matters on the
terminal. Pull out the defrost sensor in freezing
chamber according to the method in described in
Article 8.5 and then inspect the sensor against the
resistance value table in 10.6.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E5
Defrost sensor
fault in freezing
chamber
Yes
Step 1: Check whether the terminal CN1 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if therere foreign matters on the
terminal. Pull out the defrost sensor in freezing
chamber according to the method in described in
Article 8.6 and then inspect the sensor against the
resistance value table in 10.6.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E6
Communication
fault
Yes
Step 1: Check whether the terminal CN9 of the main
control board is well stuck, pull out the terminal and
re-stick it in place, and check if there is any foreign
matter on the terminal.
Step 2: Replace main control board.
Step 3: Replace display control board.
Step 4: Check whether the signal cables of the main
display board are connected.
E7
Ambient
temperature
sensor fault
Yes
Step 1: Check whether the terminal CN2 of main
control board is well stuck, pull out the terminal and
re-stick it in place and check if there is any foreign
matter on the terminal
Step 2: Check whether the sensor wiring harness are
connected.
Step 3: Replace main control board.
Step 4: Remove the temperature and humidity sensor
at the hinge, and replace the temperature and humidity
sensor.
EH
Moisture
sensor error
Yes
Step 1: Check whether the terminal CN2 of main
control board is well stuck, pull out the terminal and
re-stick it in place and check if there is any foreign
matter on the terminal
Step 2: Check whether the sensor wiring harness are
connected.
Step 3: Replace main control board.
Step 4: Remove the temperature and humidity sensor
at the hinge, and replace the temperature and humidity
Содержание 22031040001001
Страница 11: ...Service Manual_2018 V1 0 11 4 Terms 4 1 Definition of model None 4 2 Location of nameplate None...
Страница 14: ...Service Manual_2018 V1 0 14 5 5 Circuit diagram F Freezer R Refrigerator FD Freezer Defrost C Condensation...
Страница 17: ...Service Manual_2018 V1 0 17 7 2 Circulating route of cooling air...
Страница 38: ...Service Manual_2018 V1 0 38 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Страница 39: ...Service Manual_2018 V1 0 39 11 2 No working of compressor 11 3 Inside frosting no defrosting...
Страница 40: ...Service Manual_2018 V1 0 40 11 4 Inside frosting no defrosting Maintenance guidelines...
Страница 41: ...Service Manual_2018 V1 0 41 11 5 Light is not on 11 6 Air duct not operated electronically...
Страница 42: ...Service Manual_2018 V1 0 42 11 7 Fan failure 11 8 Defective defrost circuit...
Страница 43: ...Service Manual_2018 V1 0 43 11 9 Noise...
Страница 44: ...Service Manual_2018 V1 0 44 12 Figures and details of repair parts Documents are provided in the TSP...
Страница 48: ...Service Manual_2018 V1 0 48 7 Transition copper pipe Aluminium Aluminium tubes welding maintain lengthen tubes...